Content |
ACOUSTILYZER
The Acoustilyzer AL1 functionality complements and expands the ML1
Minilyzer with a new and comprehensive set of acoustical measurement
functions.
The optimized combination of electrical and acoustical features creates
the perfect all in one tool for sound/systems contractors, installers and
multi-media specialists. The Acoustilyzer AL1 is available as a palm-sized
portable acoustical analyzer or as firmware for Minilyzer owners with optional
available STI-PA measurement functionality.
Required Accessories:
The AL1 requires a measurement microphone for acquiring acoustical signals.
NTI offers the following microphones:
- MiniSPL, class 2 acc. IEC 61672
- M2010, class 1 frequency response (ext. phantom power supply required)
Product Details
Sound Pressure Level: Leq, short-time Leq , LE, Lmin, Lmax,
Real Time Analyzer: 1/1 or 1/3 octave band resolution SPL/LEQ display per
band, max - min display
Zoom FFT: Actual level and Leq, full band up to 0.7Hz resolution
Reverberation Time: RT60 with 1/1 octave band resolution, confidence indicator,
according to ISO3382
Delay Time: Propagation delay between electrical and acoustical signal (built in mic),
resolution: 0.1ms
STI-PA (optional): Single value STI or CIS test result, modulation indices display,
individual band level results, error indicator, amplitude weighting acc. IEC 60268-16
release 2003
Electrical: Level RMS, THD+N, Polarity
Measurement microphone: Required for acquiring acoustical signals, NTI offers MiniSPL
or M2010 measurement microphones
| Tests XLR, 1/4 in., 1/8 in., TT, RCA and MIDI connectors.
The intelligent, CPU-controlled CT100 accepts virtually any connector type:
XLR, mono and TRS phone (1/4 in., 1/8 in., TT), RCA and MIDI. It shows
which input pin is connected to which output pin. Separate LEDs indicate
proper shield connection and phantom power presence. The CT100 also
offers an installed cable test mode and a continuity check plus a test tone
generator.
Features
3 modes: cable test mode, installed cable test mode, and test tone mode
Accepts XLR, mono and stereo TRS phone (1/4 in., 1/8 in., TT),
RCA and MIDI Connectors
Continuity check
Intermittent detect
Phantom power detect
Grounded shield detect
Test tone generation (1 kHz and 440 Hz)
Battery operation (requires 2 AA alkaline batteries) | With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power "pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics.
SPECIFICATIONS:
- Input: 2 x XLR/f balanced
- Nominal impedance: 200 Ω
- Output 1 x XLR/m balanced
- Load impedance >200 Ω
- Symmetrically decoupled through resistors
- Total ohmic value: 200 ohms
- Typical attenuation: 6 dB
- Housing: metal casing 110 x 73 x 42 mm
| Digital Sound 8928 SPL Meter with Built-In Measurement Mic - calibrated from 300Hz to 8kHz (+/-2dB), 4 control zones in 10dB steps (40-130dB), large LCD display, peak-hold, fast/slow display modes, includes 9V battery.
A superbly designed easy to use sound level meter with features normally only found on more expensive instruments. It has an electret condenser microphone giving virtually instant readings updated every 0.5 seconds on an extra large LCD display.
- 4 measuring ranges, 40 to 70dB, 60 to 90dB, 80 to 110dB or 100 to 130dB
- 0.1dB resolution updated every 0.5 seconds
- Auto ranging or manual range selection
- ʽAʼ & ʽCʼ frequency weighting
- Fast or slow response filters
- 42mm LCD display with quasi-analogue bargraph and function Indicators
- Bargraph in 1dB steps updated every 40ms
- Max hold function to display the highest recorded value
- Min/max memory since power on or last reset
- Low battery indicator
- Auto power off
- Analogue output AC: 0.707 Vrms (at full scale)
- Supplied with battery
|
Minilyzer ML1 is the state-of-the-art analog audio meter that fits
into the palm of your hand.
It provides you with a comprehensive set of functions essential
for the analysis of professional audio systems.The powerful Minilyzer
continuously measures the audio signal and displays the desired
results with all complementary information on an illuminated hi-res
graphical LC-Display.
The Minilyzer and the MiniSPL form a comprehensive integrating
sound level meter.
MiniLINK, the USB interface for the Minilyzer allows documentation
and data acquisition of all ML1 functions in conjunction with the easy
to use MiniLINK PC application. MiniLINK supports online data logging
up to several days.
Product-details
Measurement functions:
Level RMS, Relative
Sound Pressure Level
Distortion Analyzer (THD+N), k2 - k5 harmonics
VU & PPM Meter
Speaker Polarity Test(for all speaker types)
Signal Balance Error
Frequency-/Time-Sweep Recording
1/3rd Octave Spectrum RMS & SPL
Scope
|
Cable Tester ACT-100
The Alphaton active remote cable tester can be used for testing either normal short cables or long ones, especially mufticores, wkh connectors not being accessible at one time. The tester is especially suded for fixed installations where cables can not be tested with a standard type cable tester or Ohm meter. Either symmetric and unsymmetric cables can be tested. “Cold" solderings and junction resistances are displayed by color or luminosity changes in three color LED Display. The imprinted fault table incorporates alt important fault conditions, indeed not all possible ones due to their reiatively large number. In case the display is in a state which cannot be found on the imprinted table, it can be looked up in the user's manual. In any case, however, the cabie is in aquite unusable state and should be repaired or replaced.The Alphaton cable tester has a SEND and a REMOTE section. The REMOTE sectionconsistsof two recessed mounted XLR type male or female connector and a stereo phone jack at the right hand side of the tester. Additionally, a separate REMOTE plug is delivered togetherwith the active remote cable tester for testing long cables in fixed installations.
|