Content |
OMNITRONIC AN-31, 31-band Audio-Analyzer
31-band Analyzer
* Compatible with wide-spread 31-band equalizers
* Frequency-measurement in 1/3 octaves
* 12 LED-points per frequency-band
* Peak Hold-switch for holding the levels
* Pink Noise-control for adjusting the Pink Noise-signal
* Gain-control for adjusting the input-signal
* Measuring microphone included in the delivery
* 1/4" mono-jacks for connecting the microphone on the frontpanel
* Additional RCA-plugs for digital connection on the rear panel
* Voltage selector on the rear panel
* 19“-dimensions
Power supply:230 V AC, 50 Hz ~
110 V/60 Hz
Power consumption: 20 W
Number of frequency bands: 31
Frequency range: 20 - 20 000 Hz
Frequencies (in Hz):
20, 25, 31.5, 40, 50, 63, 80, 100, 125, 160, 200, 250,
315, 400, 500, 630, 800, 1K, 1.25K, 1.6K, 2K, 2.5K,
3.15K, 4K, 5K, 6.3K, 8K, 10K, 12.5K 16K, 20K
LED-points per frequency-band: 12
Level range: -38 dB - +10 dB
Microphone connection: via 1/4" mono-jack
Pink Noise output: via 1 RCA-socket
Signal input: via 2 RCA-sockets
Dimensions: 483 x 170 x 88 mm
Weight: 3 kg
| With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power "pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics.
SPECIFICATIONS:
- Input: 2 x XLR/f balanced
- Nominal impedance: 200 Ω
- Output 1 x XLR/m balanced
- Load impedance >200 Ω
- Symmetrically decoupled through resistors
- Total ohmic value: 200 ohms
- Typical attenuation: 6 dB
- Housing: metal casing 110 x 73 x 42 mm
| Non-Contact Laser Thermometer LCD Digital IR Infrared Thermometer GM400 Temperature Meter Gun Point -50~400 Degree
This infrared thermometer USES non-contact infrared sensing technology, the target of safety, preparation, fast, reliable measurement, is widely used in measuring the mechanical, chemical, ceramics, light industry, food, metallurgy, electric power, high temperature heat treatment and other industries, dangerous and difficult to close to the surface temperature measurement. Temperature measurement is widely used in the school laboratory and home.
Objects of any temperature greater than absolute zero radiation infrared energy, this energy to around at the speed of light transmission, infrared lens collects and gathers the infrared energy to the sensor, the sensor produces a low output voltage, the voltage is proportional to the temperature of the target object, voltage after processing for the temperature value.
- Not recommended for human use.
Main features:
1. Temperature range: -50 ℃ ~ 400 ℃ (-58 ℉ ~ 752 ℉)
2. Accuracy: ± 1.5 ° C (± 2.7 ° F) OR ± 1.5% ° C
3. ℃ / ℉ conversion selection function
4. Display resolution: 0.1 ℃ or 0.1 ℉
5. Working environment: 10 ℃ - ~ 40 ℃ (50 ℉ ~ 104 ℉), relative humidity: 10 ~ 90RH no condensation
6. Storage temperature: -10- ~ 40 ℃ (14 ℉ ~ 104 ℉)
7. Detection time: ≤ 0.8second
8. Distance coefficient ratio: 12: 1 (distance and measuring point size ratio)
9. Emissivity: Preset: 0.95
10. Power supply: 2 7 batteries (purchase, replace the battery more convenient)
11. Battery life of about 12 hours
12.LED backlight (easy to use at night)
13. Automatic shutdown function (about 10 seconds)
Model |
INFRARED THERMOMETER-GM400 |
Temperature range |
-50 ℃ ~ 400 ℃ (-58 ℉ ~ 752 ℉) |
Accuracy |
± 1.5 ° C (± 2.7 ° F) OR ± 1.5% ° C |
Display resolution: |
0.1 ℃ or 0.1 ℉ |
Working environment |
10 ℃ - ~ 40 ℃ (50 ℉ ~ 104 ℉), relative humidity: 10 ~ 90RH no condensation |
Storage temperature |
-10- ~ 40 ℃ (14 ℉ ~ 104 ℉) |
Detection time |
≤ 0.8second |
Distance coefficient ratio |
12: 1 (distance and measuring point size ratio) |
Emissivity Preset: |
0.95 |
Power supply |
2 7 batteries (purchase, replace the battery more convenient) |
Battery life |
12 hours |
LED |
LED backlight |
Automatic shutdown function |
about 10 seconds |
|
Palmer Pro MCT DMX 3-pin and 5-pin DMX and XLR cable tester
MCT DMX
This cable tester checks 3-pin and 5-pin DMX cables for continuity in fully automatic or manual pin selection modes. Pin connection status of the male and female cable ends is indicated by two rows of bright LEDs. In addition, the unitʼs 3-pin connectors can also be used to test XLR microphone cables. The DMX Cable Tester comes with two L-brackets for variable mounting options.
- Tests 3-pin and 5-pin DMX cables for continuity
- Also tests 3-pin XLR microphone cables
- Automatic test mode or manual pin 1 - 5 selection
- LED indicators
- Mounting brackets included
Product type
Test Equipment
Connectors
XLR (3-pin) , XLR (5-pin)
Controls
Auto Scan , On / Off , Scan switch
Indicators
LED chain
Operating voltage
2 x AA battery
Acoustic continuity test
no
Test cable
no
Cabinet material
sheet steel
Cabinet surface
powder coated
Width
240.2 mm
Height
48 mm
Depth
53 mm
Weight
0,7 kg
|
The MiniSPL is the perfect accessory to the Acoustilyzer & Minilyzer for
acoustical measurements.
The MiniSPL is a battery powered measurement microphone. Together
with the Acoustilyzer or Minilyzer, it forms an acoustical analyzer and integrating
sound level meter. Additionally it may be operated as a stand-alone microphone
e.g. connected to a balanced audio-line, a microphone-input or a sound-card.
Product-details
? Battery powered
? Factory-set sensitivity
? No phantom power required
? 1/2" microphone, class 2 acc. IEC 61672
? Omni-directional
? Supplied with mic clamp, wind protection
? Typical frequency response included
MiniSPL together with Acoustilyzer:
? SPL Meter / RTA
? Reverberation Time RT60
? Delay Time
? FFT Analyzer
? Speech Intelligibility STI-PA
MiniSPL together with Minilyzer:
? Measurements: SPL, min./max., Leq
? 1/3rd octave spectrum analyzer | GP-300 Infrared Thermometer is specially designed to take the body temperature of a person regardless of room temperature.
Features:
- Precise non-contact measurements
- User selectable ºC or ºF
- Selectable Body and Surface temp
- Set Alarm value for fever warning
- Access to multiple memory values up to 32 records
- Trigger lock
- Automatic Data Hold & Auto power off
- Automatic selection range and Display Resolution 0.1ºC (0.1ºF)
- Backlight LCD display
- Size 149 x 95 x 44 mm
- Weight 172g
- CE certified
Specifications
|
Reviews
There are no reviews yet.