Content |
Rode's new NTK has the quality and warmth demanded from a tube mic.
With the large 1 in. capsule gold-plated membrane and twin triode tubes
(hand graded and selected), Rode is again setting the standard for value.
This is a tube mic designed exclusively for recording professionals who
want what only the best can offer.
Features:
Dynamic range of 47dB
Ultra low noise of only 12dB
Internal capsule shock mounting
Cardioid polar pattern
20Hz - 20kHz frequency response
Includes a power supply, 30 ft. cable, and stand adapter
Technical Description:
Capsule: Externally polarised 1 in. pressure-gradient condenser
Active Electronics: Unity-gain closed-loop impedance converter;
vacuum-tube input with bipolar buffering
Pickup Pattern: Cardioid
Frequency Response: 20Hz - 20kHz (+/-6dB)
Output Impedance: 200 ohms (100 ohms per leg)
Sensitivity: -38dB re 1V/Pa (12mV @ 94dB SPL) +/-1dB
Equivalent Noise: 12dB SPL (A-weighted per IEC268-15) +/-2dB
Maximum Output: > +29dBu (@ 1kHz, 5% THD into 1k (load)
Dynamic Range: > 147dB (A-weighted, per IEC268-15)
Maximum SPL: > 158dB SPL (@ 1kHz, 5% THD into 1k (load)
Signal/Noise Ratio: > 82dB (A-weighted, per IEC268-15)
External power supply: 100-120V/200-240V AC (user selectable)
50Hz/60Hz, 25VA maximum
Packed Weight: 4.53 kg (Mic only 760 gm)
Accessories included:
Power Supply
30 ft (10 m) Multicore Cable
M2 Standmount plus 3/8-5/8 in. Thread Adapter
Optional Extras: SM2 Shockmount
|
NT2-A - ?The Legend Continues? Multi Pattern 1? Condenser Microphone.
The new NT2-A carries on the tradition forged by the now legendary R?DE NT2.
A professional large capsule (1?) studio microphone incorporating three-position
pick-up patterns, pad and high pass filter switches conveniently located on the
mic body.
At the heart of the NT2-A is the Australian designed and manufactured HF1 dual
diaphragm capsule. The frequency and transient response of this new transducer
has been voiced to complement today?s modern recording techniques, and yet still
evoke the silky smooth character of the legendary microphones of the 50?s and 60?s.
These features provide the flexibility and superlative audio characteristics that make
the NT2-A one of the most versatile condenser mics available.
The NT2-A?s variable controls allow switching between Omni, Figure 8, and Cardioid
polar patterns. The three position high-pass filter provides a flat response or an 80Hz
and 40Hz high pass filter to be selected. Finally the microphones Pad can be switched
between 0 dB, -5dB and -10dB. The NT2-A comes in a soft pouch with an M2 stand mount.
SPECIFICATIONS:
Features:
The Australian designed and manufactured HF1 1? edge terminated, gold sputtered, dual
5 um diaphragm capsule. 3-position variable polar pattern: Omni, Cardioid & Figure 8; all
controlled on the mic. 3-position variable high-pass filter: Flat, 80 Hz or 40 Hz. 3-position
variable pad: 0 dB, -5 dB or -10 dB. Ultra low noise, transformerless SMT circuitry. Wide
dynamic range. High strength heat-treated steel mesh head. Durable satin nickel finish.
Internal capsule shock mounting. Supplied complete with soft pouch and clip. Designed
and manufactured in Sydney, Australia.
Operation power:
The NT2-A is designed to operate from phantom power to the P48 standard. The NT2-A will
operate between 44V and 52V applied with positive polarity to pin 2 and pin 3 of the output
XLR connector.
Operation output impedance:
The NT2-A will operate satisfactorily into a load impedance as low as 1 kΩ. If a load below this
is used, the output signal level will be reduced. The NT2-A output is balanced between pin 2 (hot)
and pin 3 (cold). Pin 1 is ground.
Acoustic principle: Externally polarized 25 mm (1?) dual diaphragm.
Directional pattern: Multi-pattern
Frequency range: 20 Hz ~ 20 000 Hz
Output impedance: 200 Ω
Signal noise ratio din iec 651:
87 dB (1 kHz rel 1 Pa; per IEC651, IEC268-15)
Equvalent noise: 7 dBA SPL (per IEC651, IEC268-15)
Maximum spl:
147 dB (@ 1% THD into 1 kΩ); 157 dB (@ 1% THD into 1 kΩ) - pad at maximum
Sensitivity: -36 dB re 1 Volt/Pascal; (16 mV @ 94 dB SPL) +/-2 dB
Dynamic range din iec 651: 140 dB (per IEC651, IEC268-15)
Power supply voltage: 48 Volts (P48)
Output connection:
3 pin XLR, balanced output between; pin 2(+) and pin 3(-); Pin 1 ground
Weight with battery: 860 grm |
Large diaphragm cardioid microphone | Pressure gradient transducer with with one-diaphragm capsule | Transformerless circuitry | Extremely low noise: 7 dB-A | Includes swivel mount | Straightforward handling for homerecording and professional studios |
High-quality professional equipment for limited budgets
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 23 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1 kohms | Equivalent noise level, CCIR1) | 17.5 dB | Equivalent noise level, A-weighted1) | 7 dB-A | Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) | 76.5 dB | Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) | 87 dB | Maximum SPL for THD 0.5%2) | 138 dB | Maximum output voltage | 13 dBu | Dynamic range of the microphone amplifier (A-weighted) | 131 dB | Supply voltage (P48, IEC 61938) | 48 V ± 4 V | Current consumption (P48, IEC 61938) | 3 mA | Matching connector | XLR3F | Weight | approx. 450 g | Diameter | 60 mm | Length | 132 mm |
|
|
NT1000 - ?Pure Performance? Ultra Versatile 1? Studio Condenser Microphone.
With its ultra low 6 dBA self-noise and transformer less SMT circuitry, the
R?DE NT1000 exhibits exceptional performance when recording both vocals
and instruments in the studio.
Voiced for ?application versatility?, the NT1000 has been hailed by many as the
ultimate drum over-head and grand piano mic selection. The NT1000 is also
equally at home as a first call vocal mic. With its Australian made 1? HF-2 capsule
incorporating internal shock mounting, the NT1000 boasts a 134 dB dynamic range,
and 140 dBA SPL capabilities and a 20 Hz ? 20 kHz frequency response.
Built of a heavy-duty cast metal satin nickel body, the NT1000 incorporates a
high-strength, heat-treated mesh head, and comes supplied in a zip pouch with a
stand mount.
SPECIFICATIONS:
Acoustic principle:
Externally polarised 1? (25mm) pressure-gradient condenser
Directional pattern: Cardioid
Frequency range: 20Hz - 20kHz
Output impedance: 100?
Signal noise ratio din iec 651:
> 88dB (A-weighted, per IEC268-15)
Equvalent noise:
6dB SPL (A-weighted per IEC268-15) +/-1dB
Maximum spl:
> 140dB SPL (@ 1kHz, 1% THD into 1k( load)
Sensitivity:
-36dB re 1V/Pa (16mV @ 94dB SPL) +/-1dB
Dynamic range din iec 651: > 134dB (A-weighted, per IEC268-15)
Power supply voltage: P48 (35V - 53V)
Current consumption: 6mA
Weight without battery: 682 gm
Weight with battery: 882 gm
| Live sound
Podcasting
Home recording
Vocals
Musical instruments |
Perception 120 |
|
- General-purpose cardioid recording microphone
- Extended frequency response
- Roadworthy construction
- Switchable 20 dB preattenuation pad
- Switchable bass cut filter
- Designed and engineered by AKG in Vienna, Austria
The Perception 120 is a 2/3-inch diaphragm true condenser microphone that offers solid build quality, outstanding performance, and excellent value. The low-mass diaphragm delivers a clear sound with accurate sonic detail. A switchable 20 dB preattenuation pad and bass cut filter make the Perception 120 an excellent choice for a wide range of recording and live sound applications.
Backed by AKG\'s six decades of experience in making microphones and input from sound engineers around the world, the Perception 120 now brings AKG studio quality to musicians and project studio applications.
Type |
2/3\" Diaphragm True Condenser |
Polar pattern |
cardioid |
Frequency range |
20 to 20,000 Hz |
Sensitivity |
22 mV/Pa (-33 dBV) |
Max. SPL |
130/150 dB (0/-20 dB) for 0.5% THD |
Equivalent noise level |
22 dB-A (IEC 60268-4) |
Signal/noise ratio (A-weighted) |
72 dB |
Preattenuation pad |
0 dB, -20 dB |
Bass filter |
12 dB/octave at 300 Hz |
Impedance |
|
Recommended load impedance |
>= 1,000 ohms |
Powering |
|
Power requirement |
48 V phantom power to DIN/IEC |
Connector |
3-pin XLR |
Finish |
metallic blue |
Dimensions |
53 dia. x 165 mm (2.1 dia. x 6.5 in.) |
Net weight |
525 g (18.5 oz.) |
Shipping weight |
955 g (33.7 oz.) |
|
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 20 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 24 dB | Equivalent SPL DIN/IEC 651 | 12 dB-A | S/N ratio CCIR 468-3 | 70 dB | S/N ratio DIN/IEC 651 | 82 dB | Maximum SPL | 114 dB for THD | Maximum output voltage | 8 dBu | Dyn. range of the mic. amplifier DIN/IEC 651 | 102 dB for THD | Supply voltage | Power supply N 149 A | Matching connector | Microphone: DIN 8F, Power Supply: XLR 3F | Weight | 460 g | Diameter | 57 mm | Length | 142 mm |
|
Reviews
There are no reviews yet.