Content |
The Shure Model VP88 is a single-point, stereo condenser microphone for use in professional studio recording, field production, electronic news gathering (ENG), and studio broadcasting applications. It combines two condenser cartridges in a single housing to create a stereo audio image of the sound source. It is unique in its ability to capture the realism of a live event and yet withstand rigorous field production environments.
The VP88 uses a mid-side (M-S) configuration. One microphone cartridge (Mid) faces forward to capture on-axis sound using a cardioid pickup pattern. The other microphone cartridge (Side) is bi-directional, capturing sound from either side. The VP88 contains an internal M-S matrix with three settings for different degrees of stereo image seperation. The internal matrix can be bypassed if an external matrix is used or if stereo imaging is done in post-production. Switches on the top of the microphone control output mode, stereo imaging, low-frequency rolloff settings, and battery on/off.
The VP88 can operate on phantom power or an internal 6V battery. The VP88 is supplied with a multi-connector "Y-splitter" cable, foam windscreen, swivel stand adapter, 6-volt battery, and zippered carrying/storage bag. Optional accessories include an isolation mount, a 7.6 m (25 ft) microphone extension cable, a phantom power supply, and a 4.3 m (14 ft) microphone stand.
- Time-coherent, Mid-Side (M-S) design for optimal stereo imaging
- Built-in stereo matrix for direct control of the stereo spread; direct M-S outputs available
- Mono compatibility ideal for broadcast applications
- 40 to 20,000 Hz frequency response
- Low noise and distortion
- Wide dynamic range
- Switch-selectable, low-frequency rolloff (12 dB/octave below 80 Hz) for reduced pickup of ambient noise and stand vibration
- Operates on phantom power or a 6V camera battery
- LED power indicator
- Internal shock mount for reduced stand vibration and handling noise
- Built-in "pop" screen
- Includes windscreen, swivel adapter, and Y-cable
|
MC10M is a multi capsule microphone set including a cardioid electret condenser microphone
(MC10) with the replaceable super cardioid capsule, shock mount adaptor, and wind screen.
MC10M can be used in wide applications, from studio & home recording to field sound aquisition.
FEATURES:
Replaceable 2 types of polar pattern capsule, cardioid/super cardioid as standard
Wide frequency response range
High sensitivity
Low distortion
High input withstand S.P.L.
Rugged brass case
Light weight
Shock mount adaptors, stereo mounting blacket & wind screen as standard
Dedicated carrying case as standard
SPECIFICATIONS:
Type :Back Electret
Condenser Microphone
Polar Pattern :Cardioid/Super Cardioid
Frequency Response :40Hz to 20kHz +/-10dB
Sensitivity :-40dBV/pa (10mv/pa)
Rated Impedance :200W
Equivalent Noise Level
:22dB (A weighted IEC/DIN 651)
Maximum S.P.L. :134dB (THD£0.5%, 1kHz)
Dynamic Range :112dB
Power Supply :48V Phantom Power
(IEC 268-15/DIN45596)
Current Consumption :3.5mA
Dimensions :?20mm x 150mm
Net Weight :130g (MC10 x 1)
Full Package Weight :865g
|
The super-cardioid e 614 is a permantly polarized condenser microphone
designed for demanding applications which require a wide frequency response,
high SPL, fast transient response and a compact design. With its frequency
response of 40 Hz to 20 kHz, the e 614 is able to capture the full sound of the
instrument, while its super-cardioid pick-up pattern isolates the microphone
from other on-stage signals.
An excellent microphone for percussion instruments, the e 614 is also an ideal
choice for woodwind and string instruments. Its excellent acoustic properties
also make it a valuable tool for home recording.
Features
Rugged design Effective rejection of incidental rear noise Excellent directivity
across the whole frequency range Full, natural sound High maximum sound
pressure level
Wide frequency response
Delivery Includes
Microphone pouch
Microphone clip MZQ 100
Technical Data
Frequency response 40 Hz ... 20 kHz
Transducer principle permanently polarized condenser
Pick-up pattern supercardioid
Sensitivity in free field, no load (1kHz) 3 mV/Pa = - 50dB (0 dB = 1 V/Pa)
Nominal impedance 50 Ohm
Min. terminating impedance 1 kOhm
Maximum sound pressure level (passiv) 139 dB/SPL
Equivalent noise level 24 dB(A)
Equivalent noise level weighted as per CCIR 468-3 35 dB
Dimensions ? 20mm, L = 100mm
Weight w/o cable 93 g
|
Technical specifications Polar pattern | | hypercardioid | Frequency range | | 50 to 20,000 Hz | Sensitivity | | 20 mV/Pa (?34 dBV) | Max. SPL | | 125 dB (k=1 %) | Equivalent noise level | | 21 dB-A | Signal/noise ratio (A-weighted) | | 73 dB | Impedance | | 600 ohms | Recommended load impedance | | >2000 ohms | Supply voltage | | 9 to 52 V phantom power, requires DPA adapter (supplied with most Installation Modules) | Current consumption | | | Connector | | Discreet Acoustics Modular standard | Finish | | matte dark gray | Dimensions | | 13.5 x 20 mm dia. (0.5 dia. x 0.8 in.) | Net weight | | 5 g (0.17 oz.) | Shipping weight | | 88 g (3.1 oz.) | Accessories (included) | | W 30 |
|
The ME 67 is a long gun microphone head designed for use with the K6 and K6P powering modules. A highly directional microphone, it can be used where the microphone must be placed at a distance from the sound source. Matt black, anodised, scratch-resistant finish.
Pick-up pattern : lobar
Sensitivity in free field, no load (1kHz) : 50 mV/Pa +- 2,5 dB
Nominal impedance : 200 Ohm (K6)
Min. terminating impedance : 1000 Ohm (K6)
Equivalent noise level : 10 dB
Dimensions : d 22,5 x 343 mm
Weight : 100 g
| The NT5 matched pairs are a masterpiece of small-diaphragm cardioid-
condenser microphone design.Intended for recording acoustic instruments,
drum overheads, cymbals and live performances, the compact externally
polarized mic employs a .5? capsule, an active J-FET impedance converter
with bipolar output buffer.
Finished in durable satin nickel, the NT5 is intended for either single or stereo
X/Y mic set-ups. The NT5 matched pairs comesupplied in a custom carry case
with windshields and mounts.
SPECIFICATIONS:
Acoustic principle: Externally polarised single diaphragm
Directional pattern: Cardioid
Frequency range: 20Hz - 20kHz
Output impedance: 100?
Signal noise ratio din iec 651: 78dB
Equvalent noise: Maximum spl: 143 dB @ 1% THD into 1k_
Sensitivity:
-38 dB re 1v/Pa ± 2 dB equivalent to 12mV/Pa where 1 Pa = 94dBSPL
Power supply voltage: P48 Supply (38V?52V), P24 Supply (20V-26V)
Current consumption: 4 mA, 2 mA,
Weight: 100g |