Content | the t.racks Phase Checker Phase Tester
- For checking acoustic transducers (loudspeakers, microphones) as well as electrical audio accessories
- Consists of a signal generator and a detector
- Generator with acoustic and electrical output
- Output level adjustable
- Detector with acoustic and electrical input (Mic int./Line in / Mic ext switchable)
- LED display
- Power supply (per device): 1x 9 V battery (not included)
|
Minilyzer ML1 is the state-of-the-art analog audio meter that fits
into the palm of your hand.
It provides you with a comprehensive set of functions essential
for the analysis of professional audio systems.The powerful Minilyzer
continuously measures the audio signal and displays the desired
results with all complementary information on an illuminated hi-res
graphical LC-Display.
The Minilyzer and the MiniSPL form a comprehensive integrating
sound level meter.
MiniLINK, the USB interface for the Minilyzer allows documentation
and data acquisition of all ML1 functions in conjunction with the easy
to use MiniLINK PC application. MiniLINK supports online data logging
up to several days.
Product-details
Measurement functions:
Level RMS, Relative
Sound Pressure Level
Distortion Analyzer (THD+N), k2 - k5 harmonics
VU & PPM Meter
Speaker Polarity Test(for all speaker types)
Signal Balance Error
Frequency-/Time-Sweep Recording
1/3rd Octave Spectrum RMS & SPL
Scope
|
Model Number |
JZK-601 |
Memory groups |
32*2 groups |
Product Dimensions |
14.3* 9.3* 3.8 CM |
Business type |
Manufacturer |
Storage temperature |
-20-50°C |
Storage Humidity |
15%-90%RH |
Operating temperature |
5-40°C |
Operating Humidity |
40%-85%RH |
Display |
LCD crystal digital display |
Measuring method |
Infrared radiation temperature measurement |
Measurement range |
32~42.5℃ fro human body, 0-100℃ for objects |
Resolution |
0.1 degrees Celsius (0.1 degrees Fahrenheit) |
Accuracy |
0-39.9kpa(0-299 mmhg) |
Voltage |
3 V |
Power consumption |
|
| With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power "pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics.
SPECIFICATIONS:
- Input: 2 x XLR/f balanced
- Nominal impedance: 200 Ω
- Output 1 x XLR/m balanced
- Load impedance >200 Ω
- Symmetrically decoupled through resistors
- Total ohmic value: 200 ohms
- Typical attenuation: 6 dB
- Housing: metal casing 110 x 73 x 42 mm
|
The dbx CT3 is an advanced cable testing unit allowing you to evaluate a large variety of cables with ease. The CT3 offers many common connectors such as RJ45, RJ11, MIDI, Speaker Twist, XLR, RCA Phono, BNC, DIN, TRS, TS, DMX, & Banana. It can be split into 2 parts, a SENDER and RECEIVER so preinstalled and long cables can be tested.
Features
- Tests up to 8-pin cables
- 2 piece chassis for testing installed cables
- Test Tone Generator
- Allows connection between different format connectors with ease
- ʽBananaʼ connector continuity tester with beeper and LED indicator
- Super-rugged construction for durability and longer life
- (2) DMX (5-pin) connectors for testing of 5 pin->to pin connections
- (2) BNC connectors for testing of 2 pin->to pin connections
- (2) RCA Phono connectors for testing of 2 pin->to pin connections
- (2) XLR connectors (1 x Male, 1 x Female) for testing of 3 pin->to pin connections
- (2) MIDI (5-pin DIN) connectors for testing of 5 pin->to pin connections
- (2) Speaker Twist connectors for testing of 4 pin->to pin connections
- (2) Banana connectors for testing of 1 pin->to pin connections
- (2) 1/4” (6.3mm) TRS/TS connectors for testing of 3 pin->to pin connections
- (2) RJ45 connectors for testing of 8P8C modular connections
- (2) 1/8” (3.5mm) TRS/TS connectors for testing of 3 pin->to pin connections
Specifications Power Requirements | (2) 9V batteries, one per side (Batteries not included) | Dimensions | 3.5” (8.9cm) (W) x 5.5” (14cm) (L) x 1.5” (3.7cm) (H) |
|
ACOUSTILYZER
The Acoustilyzer AL1 functionality complements and expands the ML1
Minilyzer with a new and comprehensive set of acoustical measurement
functions.
The optimized combination of electrical and acoustical features creates
the perfect all in one tool for sound/systems contractors, installers and
multi-media specialists. The Acoustilyzer AL1 is available as a palm-sized
portable acoustical analyzer or as firmware for Minilyzer owners with optional
available STI-PA measurement functionality.
Required Accessories:
The AL1 requires a measurement microphone for acquiring acoustical signals.
NTI offers the following microphones:
- MiniSPL, class 2 acc. IEC 61672
- M2010, class 1 frequency response (ext. phantom power supply required)
Product Details
Sound Pressure Level: Leq, short-time Leq , LE, Lmin, Lmax,
Real Time Analyzer: 1/1 or 1/3 octave band resolution SPL/LEQ display per
band, max - min display
Zoom FFT: Actual level and Leq, full band up to 0.7Hz resolution
Reverberation Time: RT60 with 1/1 octave band resolution, confidence indicator,
according to ISO3382
Delay Time: Propagation delay between electrical and acoustical signal (built in mic),
resolution: 0.1ms
STI-PA (optional): Single value STI or CIS test result, modulation indices display,
individual band level results, error indicator, amplitude weighting acc. IEC 60268-16
release 2003
Electrical: Level RMS, THD+N, Polarity
Measurement microphone: Required for acquiring acoustical signals, NTI offers MiniSPL
or M2010 measurement microphones
|
Reviews
There are no reviews yet.