TOA D-2000DA1 Mic/Line Input Module

651.04 incl. GR VAT

Available on backorder

EAN: N/A
Installments calculation
CompareAdd to wishlist Submit Better Price
The D-2000AD1 is a 4-channel Microphone/Line Input Module designed for use with the D-2008SP Digital Mixing Processor Unit. It employs XLR type connectors. Specification *0 dB = 0.775 V Input 4 channels, Mic/Line selectable Mic: -50/-36 dB*, 2.6 kΩ, electronically-balanced Line: -10 dB*, 2.6 kΩ/+4 dB*, 7 kΩ, electronically-balanced Connector: XLR-3-31 equivalent Phantom power supply […]

 

Read more

The D-2000AD1 is a 4-channel Microphone/Line Input Module designed for use with the D-2008SP Digital Mixing Processor Unit. It employs XLR type connectors.

Specification

*0 dB = 0.775 V

Input 4 channels, Mic/Line selectable
Mic: -50/-36 dB*, 2.6 kΩ, electronically-balanced
Line: -10 dB*, 2.6 kΩ/+4 dB*, 7 kΩ, electronically-balanced
Connector: XLR-3-31 equivalent
Phantom power supply (48 V DC, can be used when set for the Mic)
Ground lift switch
A/D Converter 24 bit
Sampling Frequency 48 kHz
Frequency Response 20 Hz – 20 kHz, ±1 dB (+4 dB* input)
Dynamic Range 104 dB (IHF-A weighted) or more (+4 dB* input)
Total Harmonic Distortion 0.008 % or less (+4 dB* input)
Finish Panel: Pre-coated steel plate, black, 30 % gloss
Dimensions 35 (W) × 119.5 (H) × 178.4 (D) mm (1.38″ × 4.7″ × 7.02“)
Weight 200 g (0.44 lb)

 

Weight 0.20 kg

Reviews

There are no reviews yet.

Be the first to review “TOA D-2000DA1 Mic/Line Input Module”

Your email address will not be published. Required fields are marked *

Quick Comparison

TOA D-2000DA1 Mic/Line Input Module removeTOA RM-300MF Fireman's Microphone removeINTER-M ATT-30 ATTENUATOR 330Ω, 7-30W removeINTER-M ECS-616 EMERGENCY COMBINATION SYSTEM removeINTER-M PD-659 POWER DISTRIBUTOR/CONTROL UNIT removeTOA RM-200M Remote Microphone Console remove
NameTOA D-2000DA1 Mic/Line Input Module removeTOA RM-300MF Fireman's Microphone removeINTER-M ATT-30 ATTENUATOR 330Ω, 7-30W removeINTER-M ECS-616 EMERGENCY COMBINATION SYSTEM removeINTER-M PD-659 POWER DISTRIBUTOR/CONTROL UNIT removeTOA RM-200M Remote Microphone Console remove
Image
SKUD-2000DA1RM-300MFATT-30ECS-616PD-659RM-200M
Rating
Price651.04 incl. GR VAT 840.00 incl. GR VAT 16.78 incl. GR VAT 604.87 incl. GR VAT 314.00 incl. GR VAT 492.47 incl. GR VAT
Stock

Available on backorder

Available on backorder

In stock

In stock

In stock

In stock

AvailabilityAvailable on backorderAvailable on backorderIn stockIn stockIn stockIn stock
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

The D-2000AD1 is a 4-channel Microphone/Line Input Module designed for use with the D-2008SP Digital Mixing Processor Unit. It employs XLR type connectors.

Specification
*0 dB = 0.775 V
Input 4 channels, Mic/Line selectable
Mic: -50/-36 dB*, 2.6 kΩ, electronically-balanced
Line: -10 dB*, 2.6 kΩ/+4 dB*, 7 kΩ, electronically-balanced
Connector: XLR-3-31 equivalent
Phantom power supply (48 V DC, can be used when set for the Mic)
Ground lift switch
A/D Converter 24 bit
Sampling Frequency 48 kHz
Frequency Response 20 Hz - 20 kHz, ±1 dB (+4 dB* input)
Dynamic Range 104 dB (IHF-A weighted) or more (+4 dB* input)
Total Harmonic Distortion 0.008 % or less (+4 dB* input)
Finish Panel: Pre-coated steel plate, black, 30 % gloss
Dimensions 35 (W) × 119.5 (H) × 178.4 (D) mm (1.38" × 4.7" × 7.02“)
Weight 200 g (0.44 lb)

 

The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.

Specification
Power Source 24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)
Current Consumption 120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)
Frequency Response 200 Hz - 15 kHz
Distortion 1 % or less
S/N Ratio 55 dB or more
Microphone Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
Volume Control Microphone volume control, Buzzer volume control
Connection Cable Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
Maximum Cable Distance Total 800 m (874.89 yd)
No. of Connectable RM-320F Max. 3 units
Operation Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch
Indicator Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator
Operating Temperature -5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
Operating Humidity 5 % to 95 %RH (no condensation)
Finish ABS resin, blueish gray (PANTONE 538 or its equivalent)
Dimensions 200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)
Weight 1.1 kg (2.43 lb) (with wall mounting bracket unit)
Accessory Wall mounting bracket unit …1, Wall mounting screw …2

 

The ATT-30 from Inter-M Americas is a one-gang wall panel attenuator. The knob has four clearly-labeled steps to make easy adjustments. A screwless terminal block simplifies installation, and the sleek, modern design fits into any environment. The attenuator can handle up to 30W.

- PRIORITY CONTROL

It controls the priority of emergency, timer, remote1, remote2, main(normal).

- AUTO FIRE SENSOR

The fire alarm will be given automatically to the designated areas by detecting fire sensor input.

- SPEAKER SWITCHING ON EMERGENCY OR NORMAL(MAIN)

You can control the speaker relay on emergency or normal(main) mode by using the speaker switch on front panel.

- DISPLAY STATUS

You can easily check the priority status.

- 2 AND 3 WIRE SPEAKER LINE SYSTEM

You can control the speaker line on the 2 wire system or 3 wire system.

- EXTENSION FUNCTION

You can easily expand by connecting additional ECS-616.

ECS-616

Priority Control

Emergency >Timer > Remote1 > Remote2 > Main

Link in/ out Interface

RS-422(19200bps,Data 8bits,Stop 1bit, Non Parity bit, Start1bit)

Link in/ out interface Distance

1.2 km

Operation Temperature

-10 °C ~+ 40 °C

Power Source

24V DC

Power Consumption

900mA

Weight

4.8Kg/10.6Ib

Dimensions( W x H x D)

482(W)x 88(H) x 380(D) mm / 19(W)x 3.5(H)x 15(D)in

※ Specifications and design subject to change without notice.

- SYSTEM POWER CONTROL

You can control the power of your system by using this model.

- AC AND DC POWER SUPPLY

You can distribute AC and DC power through the AC outlet and DC terminals on the rear panel.

- USE OF EMERGENCY POWER SUPPLY

For emergency equipment power supply, an extra DC terminal is provided.

- REMOTE CONTROL

You can control the system power by remote control function even though the power switch on front is off.

- AC AND DC VOLT METER

This model uses digital volt meter displays of AC and DC.

- OPERATING MODE DISPLAY

You can easily check the operating mode by LEDs, AC or DC operating and emergency power.

PD-659

AC Outlet

Switched 2000W ⅹ3

Unswitched 700W ⅹ1

Remote Control

1

DC Power Output

DC 24V 5A

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied ACmains transformer depends on country requirements)

Power Consumption

190W

Weight(SET)

6.2Kg/13.6Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

※ Specifications and design subject to change without notice.

RM-200M - Five/ten zone console for VM-2120/2240 amplfiers

The RM-200M Remote Microphone that allows announcements to be made to any speaker zone and emergency announcements to all zones on a system with the VM-2120/2240 system management amplifiers.

These announcements can be made live or pre-recorded announcements
can be activated. The remote microphone is connected by cable to the
RM-210 Remote Microphone Extension unit.

SPECIFICATIONS:

 

Power Requirement 24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.)
Distortion Less than 1%
Frequency Response 100 - 10,000 Hz
Distortion Less than 1%
Signal-to-Noise Ratio More than 60 dB
Audio Output 0 dB*1, 600 O, balanced
Microphone Unidirectional electret condenser microphone, gooseneck type.
Speaker Zone Control Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast
Emergency Broadcast Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch
Voice Announcement Board Control Activation of 5 messages*2
Number of Connectable Units Up to 4
Communication System RS-485
Volume Control Microphone volume control
Connection Cable and Connector Category 5 STP cable, RJ45 connector
Communication Distance 800 m maximum in total
Finish ABS resin
Dimensions 190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded)

*1 0 dB = 1 V
*2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier.
Weight0.20 kg1.10 kg0.50 kg4.80 kg6.20 kg3.00 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.20 kg
Weight 1.10 kg
Weight 0.50 kg
Weight 4.80 kg
Weight 6.20 kg
Weight 3.00 kg