Content |
Auto-mixing advantages
NOM (Number of Open Microphones) - automatically adjusts output level based on the total number of open microphones.Ducker function (Auto-Mute function) - automatically works to attenuate outputs of channels with low priority.
Highly effective feedback suppression.
The D-2000 Series provides feedback elimination for up to 4 channels.
In addition, each channel can control 12 problem frequencies. This
makes it convenient for feedback suppression in different areas of the
same hall. 2 versatile suppression modes.Either presettable Auto Mode or realtime Dynamic Mode can be selected to suit the situation and eliminate feedback.
Essential audio processing
Delay, High-, Low-Pass and Notch Filters, Parametric Equalizers, Compressor/Auto Leveller, Gate, Crossovers and Crosspoint Gain.
32 preset memories for user convenience.
Up to 32 different routing and parameter configurations can be stored in memory and called up to handle venues such as multi-purpose halls
and conference rooms that require frequent changes in staging,seating and speaker arrangements.
Intuitive GUI
The dedicated softwareʼs graphic, visually attractive user interface
helps streamline settings and adjustments.
Mixing console option
The D-2008SP can be connected via network to the D-2012C mixing console with 12 motorized faders and 8 rotary encoders. This enables simplified mixing operation that suit non-professional users. Using the D-2012C, allows input and output channel signal levels to be monitored,volume changes made as well as recalling preset memory settings, and contact control.
VCA control
D-2000 Series units used in conjunction with the optional D-911 VCA
Fader Unit provides more of an analog mixer user interface.
RS-232C control
The RS-232C port allows external control when connected to external
devices such as AMX*1 and Crestron*2 control units. This also allows full control over venue lighting and power curtains (blackout) from a central remote location. This feature is particularly suited for AV presentation rooms, conference rooms and hotel banquet rooms.
Specification |
| Power Source | AC mains,50/60Hz | Power Consumption | 76W | Frequency Response | 20Hz-20kHz,±1dB (±4dB Input) | Sampling Frequency | 48kHz | Input and Output | | Input: | Max.32 channels, modular construction (modules optional) | Output: | Max. 32 channels modular construction (modules optional) | Monitor Bus: | 1 stereo input, 1 stereo output | Headphone: | 1 stereo | Signal Processing | Feedback Supression Function, Auto Mixing Function,Auto Mixing Group,Parametric equalizer,High-pass filter,Low-pass filter,Notch filter,All-pass filter,High shelving filter,Low shelving filter,Horn equalizer,Crossover filter,Compressor/Auto-Leveler,Output delay,BUS delay,Matrix,CobraNet Matrix,Crosspoint Gain | Preset Memory | 32 | Auxiliary Function | Key locking function | LAN | | Network I/F: | 10BASE-T/100BASE-TX (Automatic-Negotiation) connected via a switching hub | Network Protocol: | TCP/IP | Connection Cable: | Shielded Category 5 or higher twisted pair LAN cable (CAT5-STP) | Maximum cable distance: | 100m (109.36 yd)(between D-2008SP and switching hub) | Control | RS-232C,D-sub connector (9 pins)Used for external control | Module:Remote control module slot:2 | Operating Temperature | +5ºC TO +40ºC (41ºF TO 104ºF) | Dimensions | 482(W) x 132.6(H) x 343.4(D)mm | Weight | 6.3kg (13.89lb) | Accessory | Power cord (2m (6.5ft))x 1,Rack mounting screw x 4,Module mounting screw (spare)x 4,Blank panel (preinstalled on the module slot)x 8,CD (Set-up software)x 1 | Personal Computer Requirements | | Personal Computer | PC-AT compatible | Personal Computer Requirement | | CPU: | Pentium4 2GHz or more | Memory: | 1.5GB or more (2GB or more recommended) | Display Adapter: | XGA (1024 x 768) or more | Network Adapter: | 10BASE-T or more | OS | Windows Vista,Windows XP (SP2) or later | Other | .NET Framework 3.5 SP1 (included in the supplied CD) installation required |
|
| - IT CAN CHECK SPEAKER WIRE OPEN, SHORT, AND EXCEED VALUE ACCORDING TO SETTING UP IMPEDANCE. - IT AUTOMATICALLY CHECKS SPEAKER WIRES BY PROGRAM TIMER OPERATIONS. THE POSSIBLE SET UP TIMES ARE BETWEEN 20 MINUTES AND 200 MINUTES. - RS-232C TERMINAL IN/OUT CONTROL WITH AMX/CRESTRON INTERFACE. - DC 24V OPERATION. - COMPACT DESIGN 2RU(3.5”). - KEEPS STORED VALUES BY NON VOLATILE MEMORY - ALERT SOUNDS WHEN FAULT IS FOUND - BUZZER ON/OFF FUNCTION. | | | | | SC - 624 | Power source | 24VDC | Power Consumption | 300mA | Weight | 5.2Kg / 11.5lb | Dimensions (WxHxD) | 1482 x 88 x380mm /19 x 3.5 x 15in | | | |
|
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source | 24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system) | Current Consumption | 120 mA (RM-300MF), 660 mA (with 3 RM-320F connected) | Frequency Response | 200 Hz - 15 kHz | Distortion | 1 % or less | S/N Ratio | 55 dB or more | Microphone | Unidirectional dynamic microphone with talk key, compressor (on/off switchable) | Volume Control | Microphone volume control, Buzzer volume control | Connection Cable | Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal | Maximum Cable Distance | Total 800 m (874.89 yd) | No. of Connectable RM-320F | Max. 3 units | Operation | Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch | Indicator | Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator | Operating Temperature | -5 ℃ to +45 ℃ (23 ゜F to 113 ゜F) | Operating Humidity | 5 % to 95 %RH (no condensation) | Finish | ABS resin, blueish gray (PANTONE 538 or its equivalent) | Dimensions | 200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“) | Weight | 1.1 kg (2.43 lb) (with wall mounting bracket unit) | Accessory | Wall mounting bracket unit …1, Wall mounting screw …2 |
|
The ATT-30 from Inter-M Americas is a one-gang wall panel attenuator. The knob has four clearly-labeled steps to make easy adjustments. A screwless terminal block simplifies installation, and the sleek, modern design fits into any environment. The attenuator can handle up to 30W. |
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source
|
24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)
|
Current Consumption
|
120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)
|
Frequency Response
|
200 Hz - 15 kHz
|
Distortion
|
1 % or less
|
S/N Ratio
|
55 dB or more
|
Microphone
|
Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
|
Volume Control
|
Microphone volume control, Buzzer volume control
|
Connection Cable
|
Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
|
Maximum Cable Distance
|
Total 800 m (874.89 yd)
|
No. of Connectable RM-320F
|
Max. 3 units
|
Operation
|
Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch
|
Indicator
|
Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator
|
Operating Temperature
|
-5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
|
Operating Humidity
|
5 % to 95 %RH (no condensation)
|
Finish
|
ABS resin, blueish gray (PANTONE 538 or its equivalent)
|
Dimensions
|
200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)
|
Weight
|
1.1 kg (2.43 lb) (with wall mounting bracket unit)
|
Accessory
|
Wall mounting bracket unit…1, Wall mounting screw…2
|
|
- CONSIDERATION OF USERʼS CONVENIENCE NUMERIC buttons and various function buttons are separated for timer program enter and convenience in use so that the user can easily operate. - ADOPTION OF VACUUM FLUORESCENT DISPLAY PANEL Adopting a vacuum fluorescent display of a dot matrix method enables to check operation status of each function at a glimpse. - PROGRAMMING USING A PC You can easily execute reservation setting thorough management program by connecting a PC to the RS-232C port. - VARIOUS MELODY AND SOUND OUTPUT You can generate various melodies and sounds by linking the flash memory mounted on this unit to our model, PV-632 (MULTI-VOICE FILE). - AC POWER OUTPUT CONTROL When PW-642 and other equipment are connected via the AC outlet terminal of PW-642, you can turn ON/OFF the AC outlet button in the front panel and manually control ON/OFF of the AC power connected to other device. - BACK-UP POWER You can continue to maintain the time counter for about a week though the inner back-up even though AC power turns off with current time set. There is no need of readjusting time even though AC power is applied. - MEASURE AGAINST POWER FAILURE A separate memory is used to prevent data extinguishment due to power failure or other unstable power. - AUTOMATIC RETURN In programming data using a key button on the front side of PW-642 without using a PC, no pressing any button is recognized as cancel of program entry to return to normal operation status. - AC POWER OUTPUT TIME ADJUSTMENT You can adjust the AC power output time of PW-642 by 1~20sec to prevent time delay from occurring in the interface with the outside power amp. - KEY LOCK You can protect reservations and userʼs setting. |
|
|
| | PW - 642 | Input Channel (Balanced) | 5CH | Output Channel (Balanced) | 4CH | Output Level | Maximum 1v | AC Power Output 1 | Maximum 500W | AC Power Output 2 | Maximum 30 w | Data Preservation Time | 7 days and more | Melody Time (15 settings total - 247 seconds) | No.1 | 2 seconds | No.2 | 3 Seconds | No.3 | 3 Seconds | No.4 | 5 Seconds | No.5 | 5 Seconds | No.6 | 7 Seconds | No.7 | 7 Seconds | No.8 | 10 Seconds | No.9 | 10 Seconds | No.10 | 15 Seconds | No.11 | 20 Seconds | No.12 | 30 Seconds | No.13 | 30 Seconds | No.14 | 40 Seconds | No15 | 60 Seconds | Operation Temperature | -10°C ~+ 40°C | Power Source | 100- 120 VAC or 220 -240VAC; 50/60 Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 10W | Weight(SET) | 5.7Kg/12.6Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | ※ Specifications and design subject to change without notice. | | | |
|