The VX-2000SF Surveillance Frame is the output matrix section of the VX-2000 system that assigns audio signals to individual zones from 4 audio buses. It can be extended to up to 5 units. A total of 10 units of output modules and control modules can be installed per VX-2000SF. The following 4 types of modules can be used: the VX-200SP Pilot Tone Detection module, the VX-200SZ Impedance Detection module, the VX-200SI Control Input module, and the VX-200SO Control Output module.
* 0 dB = 1 V Power Source | 24 V DC (operating range: 20 - 40 V DC)
M3.5 screw terminal, distance between barriers: 8.8 mm | Current Consumption | Under 2 A (40 V DC) | Number of Module Slot | 10, usable modules: VX-200SZ, VX-200SP, VX-200SI, VX-200SO | Frequency Response | 20 - 20,000 Hz | Signal to Noise Ratio | Over 60 dB | Distortion | Under 0.5% | Cross Talk | Under -60 dB (1 kHz, 0 dB*) | Audio Link Input/Output | Number of audio busses: 4
0 dB*, electronically balanced, RJ45 female connector
Twisted-pair straight cable (TIA/EIA-586A standard) | Standby Amplifier Link | RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Twisted-pair straight cable (TIA/EIA-586A standard) | Communication System | VX-2000, VX-2000SF: RJ45 female connector × 2, LONWORKS RS-485
VX-2000DS: RJ45 female connector × 2,
Twisted-pair straight cable (TIA/EIA-586A standard) | Operating Temperature | 0℃ to +40℃ | Finish | Panel: Surface-treated steel plate, black, 30% gloss, paint | Dimensions | 482 (W) × 132.6 (H) × 337 (D) mm | Weight | 5.6 kg | Accessory | Rack mounting screw……4, Fiber washer……4, Blank panel……9,
Rack mounting bracket (preinstalled on the unit) ……2,
Standby amp. cable (3 m) ……1, Blank panel mounting screw……18 | Option | Isolation transformer: IT-450 (audio link output) |
|
The RM-210 is an extension unit for increasing the number of function keys of TOA's RM-200M, RM-200XF and RM-200X Remote Microphones.
Specification |
| Current Consumption | 20mA max. (in terms of RM-200M's DC power input 75mA max. (interms of DC power inputs of RM-200X and RM-200XF) | Connection | Connection to RM-200M, RM-200X or RM-200XF by way of dedicated Cable | Number of Function | Keys 10 | Function | When used to expand the RM-200M:
Selects and activates the Voice Announcement Board messages.
When used to expand the RM-200X and RM-200XF (PC software setting):
Emergency activation, emergency reset, BGM pattern selection, EV message activation, broadcast zone selection, monitor zone selection, chime activation, Talk switch activation, control output activation, input volume adjustment, zone volume adjustment, and failure output indication and reset. | Finish | ABS resin, bluish gray (PANTON 538 or its equivalent) | Dimensions | 110 (W) x 76.5 (H) x 215 (D)mm | Weight | 350g | Accessory | Extension cable x 1, Linkage bracket A x 1, Linkage bracket B x 1, Screw for linkage bracket x 12 |
|
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source | 24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system) | Current Consumption | 120 mA (RM-300MF), 660 mA (with 3 RM-320F connected) | Frequency Response | 200 Hz - 15 kHz | Distortion | 1 % or less | S/N Ratio | 55 dB or more | Microphone | Unidirectional dynamic microphone with talk key, compressor (on/off switchable) | Volume Control | Microphone volume control, Buzzer volume control | Connection Cable | Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal | Maximum Cable Distance | Total 800 m (874.89 yd) | No. of Connectable RM-320F | Max. 3 units | Operation | Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch | Indicator | Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator | Operating Temperature | -5 ℃ to +45 ℃ (23 ゜F to 113 ゜F) | Operating Humidity | 5 % to 95 %RH (no condensation) | Finish | ABS resin, blueish gray (PANTONE 538 or its equivalent) | Dimensions | 200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“) | Weight | 1.1 kg (2.43 lb) (with wall mounting bracket unit) | Accessory | Wall mounting bracket unit …1, Wall mounting screw …2 |
|
- CONVENIENT INSTALLATION AND CONSTRUCTION WITHOUT NEED OF ID SETTING. - ADOPTION OF RS-422 COMMUNICATION METHOD TO SUPPORT A LONG DISTANCE. - REMOTE CONTROL FOR ZONE VOLUME AND SELECTION OF BGM. - INDEPENDENT LOCAL MIC AND BGM BROADCASTING. | Audio Output | 0dB(Balanced) | Audio Input | Paging & RM MIC & LM MIC | -50dB(Balanced) | BGM(Main & Local) | -10dB(Balanced) | Tone Control (100Hz & 10kHz) | Paging MIC | ± 10dB | Audio Output | ± 12dB | Frequency Response | BGM | ± 3dB | MIC | ± 3dB | S / N | BGM | Better than 75dB | MIC | Batter than 65dB | T.H.D. | BGM | Less than 0.05% | MIC | Less than 0.05% | Priority Control | Paging MIC > DRP > RM1> RM2 > RM3 > RM4 > LM-8000 > Main BGM | Phantom Power | DC 24V | Serial Interface | Communication Speed | 9600bps | Communication Distance | Maximum 300m(UTP CAT%) | Operation Temperature | -10℃ ~ +40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Weight(SET) | 130g / 0.28lb | Dimensions(SET) | 70(W) x 114(H) x 52(D)mm 2.8(W) x 4.5(H) x 2.0(D)in | ※ Specifications and design subject to change without notice. |
|
The AT series high quality attenuators features 5 attenuation settings ,,OFF'' -18dB,-12db,-6dB,-0dB. An input range from 0.5W to 60W (model dependent), and push-in connectors. Push-in connector allows quick terminal cable connection. Stylishly finished, the AT Series will suit any décor. |
Five attenuation settings (OFF, 0/-6/-12/ -16dB), over an input range from 0.5W to 30W. |