Content |
Κεντρική μονάδα για την διαχείριση συστήματος ανακοινώσεων τύπου SX-2008 με 8 x Control inputs, 8 x Control outputs, failure status output & failure data inputs/switches. Λήψη δεδομένων από συμβατές συσκευές τύπου SX-xxxx μέσω δικτύου fast Ethernet.
Specification |
| Power Source | Usable power supply unit: VX-200PS 24V DC (operational range: 20V – 40V DC) Two power inputs construction enables dual- redundant power supply. | Current Consumption | Under 1.1A (maximum value in the power operating range) Under 0.8A (when operated on 24V DC) | Indication/Operation | SX link access indicator: 2 LAN access indicator: 1 Mode indicator: 3 (EMERGENCY/STANDBY/CPU OFF) Failure indicator: 3 (GENERAL/CPU/SX LINK) Power indicator: 1 (POWER) Run indicator: 1 (RUN) Failure control switch: 3 (AUX/RESET/LAMP TEST) | SX Link | | Network I/F | 2 100BASE-TX circuits, RJ45 connector | Matrix System Specification | Bus: 16 Audio input: Max. 64 ch Audio output: Max. 128 zones Contact input: Max. 136 Contact output: Max. 136 Priority control: 256 steps Event log: Max. 10,000 events | Matrix System Configuration | Connectable SX-2100AI No: Max. 8 units Connectable SX-2000AO No.: Max. 16 units Connectable RM-200S No.: Max. 32 units (up to 4 RM-200S per SX2100AI) | Connection Cable/Device | Shielded Category 5 twisted pair cable for LAN (CAT5-STP)(Connect SX-2100AI and SX-2000AO via the switching hub specified by TOA) Note: This network must be made physically independent from other LAN. | Switching Hub | 7 stages | Maximum Cable Distance | 100m (between this unit and a switching hub) | LAN | | Network I/F | 1 10 BASE-T/100 BASE-TX circuit (selectable by automatic recognition), RJ45 connector for maintenance use | Network Protocol | TCP/IP | Connection Cable | Shielded Category 5 twisted pair cable for LAN (CAT5-STP) | Maximum Cable Distance | 100m (between this unit and a switching hub or PC) | Analog Link | Input/Output Connector Output: 2, RJ45 connector Connection Cable Shielded Category 5 twisted pair cable for LAN(CAT5-STP) (1 pair of audio wire + 1 pair of CPU OFF + 1 pair of control wire (system reset/standby) + 1 pair of connection check wire) | Maximum Cable Distance | Total length of analog audio link: 800m | Failure Data Input | 3 inputs (ACK/RESET/LAMP TEST), no-voltage make contact input,open voltage: 24V DC, short-circuit current: 2mA, photo coupler input,removable terminal block (12 pins) | Failure Data Output | 4 outputs (CPU FAULT/GENERAL FAULT/CPU OFF/BUZZER), C contact, no-voltage make contact output, relay contact output (withstand voltage: 40V DC, control current: 2 – 300mA), RJ45 connector | Control Input | 8 inputs, no-voltage make contact input, open voltage: 24V DC, short-circuit current: 2mA, photo coupler input, removable terminal block (12 pins) | Control Output | 8 outputs, C contact, no-voltage make contact output, relay contact output (withstand voltage: 40V DC, control current: 2 – 300mA), removable terminal block (12 pins) | Memory Card | Insertion slot: 1 (use of supplied CF card (128MB)), set data and log data stored | Operating Temperature | 0°C to +40°C | Operating Humidity | 35% to 80% RH (no condensation) | Finish | Panel: Aluminum, black, alumite, Case: Surface-treated steel plate | Dimensions | 482 (W) × 44 (H) × 333 (D)mm | Weight | 3.8kg | Accessory | CD (PC setting software) × 1, CF card (128MB) × 1, Removable terminal plug (4 pins) × 1, Removable terminal plug (12 pins) × 4, Rack mounting screw × 4, (–) Screw driver × 1 |
|
Πεδίο επέκτασης 20 πλήκτρων του μικορφώνου RM-300MF
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source
|
24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)
|
Current Consumption
|
120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)
|
Frequency Response
|
200 Hz - 15 kHz
|
Distortion
|
1 % or less
|
S/N Ratio
|
55 dB or more
|
Microphone
|
Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
|
Volume Control
|
Microphone volume control, Buzzer volume control
|
Connection Cable
|
Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
|
Maximum Cable Distance
|
Total 800 m (874.89 yd)
|
No. of Connectable RM-320F
|
Max. 3 units
|
Operation
|
Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch
|
Indicator
|
Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator
|
Operating Temperature
|
-5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
|
Operating Humidity
|
5 % to 95 %RH (no condensation)
|
Finish
|
ABS resin, blueish gray (PANTONE 538 or its equivalent)
|
Dimensions
|
200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)
|
Weight
|
1.1 kg (2.43 lb) (with wall mounting bracket unit)
|
Accessory
|
Wall mounting bracket unit…1, Wall mounting screw…2
|
|
Emergency combination system. Ενσωματώνεται σε σύστημα συναγερμού φωτιάς. Ενσωματωμένο πυκνωτικό μικρόφωνο για Επείγουσα Αναγγελία, Εξωτερική αυτόματη αναγγελία με αρχείο φωνής, Επιλογέας δοκιμής. Ρύθμιση έντασης εξόδου, Βάρος 4,6kg. Διαστάσεις (WxHxD): 482X88X380mm |
The AT series high quality attenuators features 5 attenuation settings ,,OFF' -18dB,-12db,-6dB,-0dB. An input range from 0.5W to 60W (model dependent), and push-in connectors. Push-in connector allows quick terminal cable connection. Stylishly finished, the AT Series will suit any décor. |
Rack system με ανεμιστήρες. Επιλογή λειτουργίας: αυτόματο, χειροκίνητο, θερμοκρασία λειτουργίας. 2 DC ανεμιστήρες. Power Source 24 VDC. Βάρος 4kg. Διαστάσεις 482Χ88Χ380 mm
PF- 602
|
Operation Selector Switch
|
Manual, Auto, Operating temperature
|
Fan
|
2 DC fans
|
Power Source
|
24VDC
|
Power Consumption
|
160mA
|
Weight
|
4Kg/8.8Ib
|
Dimensions( W x H x D)
|
482x 88 x 380 mm / 19 x 3.5 x 15in
|
※ Specifications and design subject to change without notice.
|
|
Συσκευή επέκτασης AC εξόδων για το PD-659.
|
- SYSTEM POWER CONTROL
It controls the power of the rack system over all working together with the PD-659.
- AC OUTLET TERMINAL
To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds.
| | | | |
PD- 658
|
AC Outlet
|
Switched 2000W ⅹ3
|
Operation Temperature
|
-10℃~+40℃
|
Power Source
|
100-120VAC or 220-240VAC; 50/60Hz
(Supplied AC mains transformer depends on country requirements)
|
Power Consumption
|
10W
|
Weight(SET)
|
4.6Kg/10.1 Ib
|
Dimension(SET)
|
482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in
|
| | |
|
Αξιολογήσεις