Content | Replacement stylus for AT91 cartridge.
The ATN91 is also compatible stylus for CN5625AL and AT90 discontinued cartridges.
The ATN91 is also upgrade replacement styli for AT3600L.
The tracking force of AT3600L equipped with ATN91 is 2g, do not upgrade from ATN3600L to ATN91 when your tonearm does not allowed tracking force adjustment. |
Stylus 3E
Technical data |
|
Frequency range |
20-20.000 Hz |
Frequency response |
20-18.000 Hz + 2 / - 3 dB |
Tracking ability at 315Hz at recommended tracking force *) |
60 µm |
Compliance, dynamic, lateral |
20 µm/mN |
Stylus type |
Elliptical |
Stylus tip radius |
r/R 8/18 µm |
Equivalent stylus tip mass |
0,5 mg |
Tracking force range |
1,5-2,0 g (15-20 mN) |
Tracking force, recommended |
1,75 g (17,5 mN) |
Tracking angle |
20° |
Stylus colour |
Black |
|
|
Recommended for following cartridges |
OM 3E, OMP 3E |
*) Typical value
| Stylus 2M Blue
Technical data |
|
Frequency range |
20-25.000 Hz |
Frequency response |
20-20.000 Hz + 2 / - 1 dB |
Tracking ability at 315Hz at recommended tracking force *) |
80 µm |
Compliance, dynamic, lateral |
20 µm/mN |
Stylus type |
Nude Elliptical |
Stylus tip radius |
r/R 8/18 µm |
Equivalent stylus tip mass |
0,5 mg |
Tracking force range |
1,6-2,0 g (16-20 mN) |
Tracking force, recommended |
1,8 g (18 mN) |
Tracking angle |
20° |
Stylus colour |
Blue |
|
|
Recommended for following cartridges |
2M Blue |
*) Typical value |
Ortofon 530MKII Stylus Technical Data
Frequency range 20-25.000 Hz
Frequency response 20-20.000 Hz + 2 / - 3 dB
Tracking ability at 315Hz at recommended tracking force 80 µm
Compliance, dynamic, lateral 30 µm/mN
Stylus type Nude Fine Line
Stylus tip radius r/R 8/40 µm
Equivalent stylus tip mass 0,3 mg
Tracking force range 1,25-1,75 g (12,5-17,5 mN)
Tracking force, recommended 1,75 g (17,5 mN)
Tracking angle 20°
Stylus colour Black
Recommended for following cartridges Series 530 Mkll, 530, 530 P |
|
Ortofon 14 Stylus Technical Data
Frequency range 20-22.000 Hz
Frequency response 20-20.000 Hz + 2 / - 2 dB
Tracking ability at 315Hz at recommended tracking force *) 70 µm
Compliance, dynamic, lateral 25 µm/mN
Stylus type Elliptical
Stylus tip radius r/R 8/18 µm
Equivalent stylus tip mass 0,5 mg
Tracking force range 1,0-1,5 g (10-15 mN)
Tracking force, recommended 1,25 g (12,5 mN)
Tracking angle 20°
Stylus colour Black
Recommended for following cartridges TM 14U |
|
Stylus 40
Technical data |
| Frequency range | 20-30.000 Hz | Frequency response | 20-30.000 Hz + 2 / - 3 dB | Tracking ability at 315Hz at recommended tracking force *) | 90 µm | Compliance, dynamic, lateral | 25 µm/mN | Stylus type | Nude FG 70 | Stylus tip radius | r/R 5/70 µm | Equivalent stylus tip mass | 0,3 mg | Tracking force range | 1,25-1,75 g (12,5-17,5 mN) | Tracking force, recommended | 1,5 g (15 mN) | Tracking angle | 20° | Stylus colour | Black |
| | Recommended for following cartridges | OM 40, OM 40 GOLD | *) Typical value |
Reviews
There are no reviews yet.