Content |
With durable construction and unobtrusive appearance, the ES933C offers versatile solutions for speech, theater, orchestra and choir sound reinforcement and recording. The microphone's low-profile element provides a uniform cardioid polar pattern with 120º acceptance angle. Available in two colors: black (ES933C); white (ES933WC), the microphone offers unsurpassed immunity from radio frequency interference thanks to UniGuard® innovations. The ES933C also offers an 80 Hz low-cut UniSteep® filter that reduces pickup of low-frequency ambient noise.
- Designed for quality sound reinforcement, professional recording, television and other demanding sound pickup applications
- Small size and excellent response are ideal for suspension over choirs, instrumental groups and theater stages
- Low-profile element provides uniform cardioid polar pattern with 120º acceptance angle
- Available interchangeable elements permit angle of acceptance from 90º to 360º
- Superior off-axis rejection for maximum gain before feedback
- Requires 11V to 52V DC phantom power
- UniGuard® RFI-shielding technology offers outstanding rejection of radio frequency interference (RFI)
- Integral UniSteep® filter provides a steep low-frequency attenuation to improve sound pickup without affecting voice quality
- Available in two colors: black (ES933C) and white (ES933WC)
- RoHS compliant - free from all substances specified in the EU directive on hazardous substances
- Element: Fixed-charge back plate, permanently polarized condenser
- Polar Pattern: Cardioid
- Frequency Response: 30-20,000 Hz
- Low Frequency Roll Off: 80 Hz, 18 dB/octave
- Open Circuit Sensitivity: -40 dB (10.0 mV) re 1V at 1 Pa
- Impedance: 250 ohms
- Maximum Input Sound Level: 138 dB SPL, 1 kHz at 1% T.H.D.
- Dynamic Range: 109 dB, 1 kHz at Max SPL
- Signal to Noise Ratio: 65 dB, 1 kHz at 1 Pa
- Phantom Power Requiremens: 11-52V DC, 2 mA typical
- Switch: Flat, roll-off
- Cable: 15.2 m (50') long (permanently attached to microphone), 3.2 mm (0.13“) diameter, 2-conductor shielded cable, terminated with TA3F-type connector
- Accessories: ES933C: AT8109 two-stage foam windscreen; AT8452 steel hanger ES933WC: AT8109(WH) two-stage foam windscreen; AT8452(WH) steel hanger Both: AT8538 power module
|
- PA microphone with rugged, all-metal body
- Frequency response optimized for intelligibility
- Long useful life even in tough day-to-day usage
- Frequency response tailored to speech use
Rugged, affordable dynamic cardioid gooseneck microphone for general public address and communications use. The DST 99 S provides a frequency response tailored to speech use for optimum intelligibility as well as good offaxis rejection for high gain before feedback and suppression of unwanted ambient noise. The all-metal body ensures a long useful life for the microphone even in tough day-to-day use.
The DST 99 S is mounted on a table stand with an on/off switch and coiled cable with 3-pin XLR connector.
Ticket window, bank counter
Reception desk, restaurant
Houses of worship
Polar pattern cardioid
Frequency range 150-15,000 Hz
Sensitivity 2.2 mV/Pa (-54 dBV)
Max. SPL 133 dB (1% THD)
Equivalent noise level 21 dB-A
Signal/noise ratio (A-weighted) 73 dB
Impedance 530 ohms
Recommended load impedance >2,000 ohms
Connector 3-pin male XLR
Finish matte black
Net weight 805 g (1.8 lbs.)
Shipping weight 1,125 g (2.5 lbs.)
|
The CMX380 is a mini hanging cardioid microphone designed to be used in choirs, instrumental groups and theatres, but itʼs technical qualities and design will also justify itʼs use in several recording / reproduction applications.
The unidirectional cardioid polar pattern reduces feedback to an absolute minimum. Due to the flat frequency characteristic, users, musicians, singers and performers will experience a clear natural reproduction of their instrument or voice, even when exposed to loud powerful sounds.
The slimline modest design will not disctract the attention from the vocal of instrumental performance, and will flawlessly blend into the background.
- Model Name / Type: AUCMX380 / hanging back electret condenser microphone
- Polar Pattern: Cardioid
- Impedance: 200 ohms
- Frequency Response: 50 Hz - 18 kHz
- Sensitivity: - 42 +/- 3 dB
- Dynamic Range: 113 dB
- Phantom Power 11 - 52 V DC
- Diameter: 13,5 mm
- Length: 55 mm
|
- Cardioid instrument microphone with miniature mounting bracket
- High mechanical-noise attenuation
- Including wireless direct adapter for easy use with AKG pocket transmitters
- Detachable microphone cable
- Ideal for miking up accordions and guitar, piano, keyboard, or organ amplifiers
Polar pattern | cardiod | Frequency range | 60 Hz to 20 kHz | Sensitivity | 5 mV/Pa (-46 dBV) | Max. SPL | 130/132 dB SPL (bei k = 1 %/3 %) | Equivalent noise level | 31 dB(A) | Signal/noise ratio (A-weighted) | 63 dB | Impedance | = 2000 ohms | Current consumption | |
|
Polar pattern Cardioid
Frequency range 70 to 18,000 Hz
Max. SPL 125 dB (for 1% THD)
Equivalent noise level 73 dB
Impedance =2,000 ohms
Supply voltage 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering |
AKG GN 30 OC., 12 inch gooseneck for D.A.M.-microphone capsules, 3/8“-connector, programmable indicator LED, incl. 10ft. cable to open-end, black, for installations |
Reviews
There are no reviews yet.