Content | Specifications :
- Type Back Electret Condenser
- Polar Pattern Omni-Directional
- Frequency Response 80Hz - 16KHz
- Sensitivity -52 + 3db
- Impedance 680 Ω
- Max.Input SPL 128db
- Power Requirement 1,5 - 10 vdc
- Cable Lenght 1 m
- Weight 5 g
- Capsule Diameter O 25
- Accessories Windscreen
- Available Connectors 3-pin mini XLR
|
Miniaturized lavalier condenser microphone for wireless or wired applications.
The ADX10 is a miniaturized condenser microphone designed for lavaliere applications such as speech, presentation and theatrical production. The ADX10 has the ability to accurately capture and reproduce vocals from a comfortable distance of 4“- 8“. This mic is clear, resistant to feedback and easy to use.
Designed with a uniformly controlled cardioid polar pattern, the ADX10 helps to isolate the area or section being miked from other vocals or instruments on stage. The ADX10 has a smooth, accurate frequency range of 50 Hz - 18 kHz. This mic is lightweight, low profile and has a natural sound with exceptional sound response.
Primarily for use with the Audix RAD360 Wireless System, the ADX10 includes a tie-clip and a 3' attached cable terminating to a mini-XLRf connector.
MODEL VARIATIONS:
ADX10P - For hard wired application. Includes an 8' cable terminating to a mini-XLRf connector tie clip, external windscreen and a phantom power adapter module. 9 - 48 V phantom power required.
Type | Pre-polarized Condenser | Polar Pattern | Cardioid | Frequency Response | 50Hz - 18kHz | Impedance | 250 Ohms | Sensitivity | 5 mV/Pa @1k |
|
Shure WL-185 Lavalier Condenser Microphone
Models WL183, WL184 and WL185 are lavalier electret condenser mics designed for use
with a wireless body-pack transmitter. Each mic has a 1.2 meter (4 ft.) cable terminated
with a miniature 4-pin mini connector. Included tie clip can be rotated in 90 degree intervals for placement flexibility.
WL185 (Cardioid):
Recommended for general purpose sound reinforcement applications requiring good rejection of ambient noise.
Use of windscreen highly recommended. Pickup angle: 130 degrees.
Type
Condenser (electret bias)
Frequency Response
50 to 17,000 Hz
Output Impedance
1800 ohms
Sensitivity (1 Pa = 94 dB SPL)
WL183: -40.0 dBV/Pa
WL184: -44.5 dBV/Pa
WL185: -45.5 dBV/Pa
Maximum Sound Pressure Level
WL183: 125.0 dB SPL
WL184: 129.5 dB SPL
WL185: 130.5 dB SPL
Output Noise (A-weighted)
WL183: 22.5 dB SPL
WL184: 27.0 dB SPL
WL185: 28.0 dB SPL
Dynamic Range
102.5 dB
Polarity
Positive pressure on diaphragm produces positive voltage on pins 3 and 4 relative to pin 1.
Power Requirements
Regulated nominal +5 Vdc (1.5 Vdc to 10 Vdc) provided at microphone connector pin 2 relative to pin 1 of a Shure wireless microphone transmitter.
|
Type Condenser - Omni
Frequency Ressponse 60Hz - 18kHz
Sensitivity -33.5dB re 1 Volt/Pascal (21.00mV @ 94 dB SPL) +/- 2 dB @ 1kHz
Resistance 3000Ω
Dimensions 4.50mmW x 12.00mmH x 4.50mmD
Weight 1.00gm
Accessories Αntitrauma case,WS-LAV, Minifur LAV, Micon cable, Spanner |
Low-profile, cost efficient clip-on microphone for applications including houses of worship, lecturers, etc. Connects to AKG bodypack transmitters. The CK 99 L provides a natural sound, with a slight rise above 10 kHz for added clarity. Its cardioid polar pattern and bass rolloff combine to suppress unwanted ambient noise. Hide and speak for house-of-worship, conference and theater applications The CK99 L is a condenser lavalier microphone with cardioid polar pattern. It provides a natural sound, with a slight rise above 10kHz for added clarity, perfect for applications in houses of worship, lectures and theaters. Thanks to its small housing and the included durable metal clip, it can be inconspicuously and securely mounted on jackets and costumes. The CK99 L provides a professional three-pin mini XLR connector that fits the body pack transmitters of all AKG wireless microphone systems. Cardioid polar pattern eliminates noise from the rear 125° pickup angle for inexperienced or very vivacious talkers Small housing and durable metal clip for inconspicuous, secure mounting Technical Specification General | Audio Frequency bandwidth | 15 to 18000 Hz | Sensitivity | 8.8 mV/Pa | Equivalent Noise Level | 34 dB-A | Signal to Noise | 60 dB-A | Electrical Impedance | 200 Ohms | Recommended Load Impedance | 2000 Ohms | | Polar Patterns | Cardioid | | | Powering Interface | Voltage | 1.5 to 10 V | Current | 2 mA | | Audio Output | Type | Mini XLR | Gender | Female | Contacts | 3-pin | | Design | | Dimensions / Weight | Height | 23 mm | Diameter | 8 mm | Net Weight | 2.5 g | |
|
Micro-sized lavalier condenser microphone for wireless and wired applications.
Cardioid microphone with 8ʼ cable terminating to a mini-XLRf connector with phantom power adapter for hard wired applications.
Includes APS910
phantom power adapter. 9-52 V phantom power. Black.
|
Reviews