Content |
Audio selector SP 28 is designed for specific sound reinforcement applications, fixed installations and recording studios.
Front panel:
· 4 rotary potentiometers separately adjusting the output level of the 4 stereo systems (Left and Right)
· 4 push-buttons, without detent, that activate (LED on) the relevant outputs of the 4 stereo systems (Left and right)
· 1 "Priority” push-button, with detent, to activate the output of the selected system while excluding the previous one
· 1 "Left” push-button, with detent, activating all the outputs associated with the left channel
· 1 "Right” push-button, with detent, activating all the outputs associated with the right channel
· "Power” switch
Rear panel:
· 1 connector to link the external power unit (supplied)
· 2 electronically balanced inputs of the Left and Right channels (XLR-M Neutrik)
· 8 electronically balanced outputs of the 4 stereo systems (XLR-F Neutrik)
· All the inputs and outputs with the Ground-Lift switch
· Frequency response (@-3 dB) 10 Hz to 20 kHz
· THD + N 0.001%
· Input impedance 22K ohm balanced
· Gain 6 dB
· Signal/noise ratio > 110 dB
· Max input level 20 dB
· CMRR > 50 dB
· Separation between channels (@ 100Hz, 1 kHz, 10kHz) 76 dB, 55 dB, 36 dB
· Max output (@ 10 K ohm) 26 dBu
· Output impedance 600 ohm
· Connectors: XLR-F inputs, XLR-M outputs
· Power supply 230 Vac, 50 Hz
· Dimensions (WxHxD) 482x44x205 mm
· Weight 2.4 kg
|
Volume Control 12W with priority.
|
This model should be used with concerning equipment (emergency switcher-our model ES-9116, matrix-our model PX-9116, emergency panel-our model EP-9216). Specification Brand | InterM | Model | RG-9116 | Features | Speaker line switching; broadcasting status indicators (LED). | Power supply | 24V DC | Dimensions | 482 x 44 x 280 mm | Weight | 3,8 kg | Warranty | 12 months |
|
| - CONVENIENT INSTALLATION AND CONSTRUCTION WITHOUT NEED OF ID SETTING. - SELECTION OF VARIOUS CHIME BROADCASTINGS FOR MIC BROADCASTING (PRE/POST). - CONVENIENT PRIORITY BROADCASTING. - ADOPTION OF OUTPUT SIGNAL LEVEL DISPLAY. - ADOPTION OF RS-422 COMMUNICATION METHOD TO SUPPORT A LONG DISTANCE. | | | | | | Audio Output | 0dB(Balanced) | Audio Input | Paging & RM MIC & LM MIC | -50dB(Balanced) | BGM(Main & Local) | -10dB(Balanced) | Tone Control (100Hz & 10kHz) | Paging MIC | ± 10dB | Audio Output | ± 12dB | Frequency Response | BGM | ± 3dB | MIC | ± 3dB | S / N | BGM | Better than 75dB | MIC | Batter than 65dB | T.H.D. | BGM | Less than 0.05% | MIC | Less than 0.05% | Priority Control | Paging MIC > DRP > RM1> RM2 > RM3 > RM4 > LM-8000 > Main BGM | Phantom Power | DC 24V | Serial Interface | Communication Speed | 9600bps | Communication Distance | Maximum 300m(UTP CAT%) | Operation Temperature | -10℃ ~ +40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Weight(SET) | 1.5kg / 3.2lb | Dimensions(SET) | 200(W) x 70(H) x 206(D)mm 7.9(W) x 2.8(H) x 8.1(D)in | ※ Specifications and design subject to change without notice. | | | |
|
- CONSIDERATION OF USERʼS CONVENIENCE NUMERIC buttons and various function buttons are separated for timer program enter and convenience in use so that the user can easily operate. - ADOPTION OF VACUUM FLUORESCENT DISPLAY PANEL Adopting a vacuum fluorescent display of a dot matrix method enables to check operation status of each function at a glimpse. - PROGRAMMING USING A PC You can easily execute reservation setting thorough management program by connecting a PC to the RS-232C port. - VARIOUS MELODY AND SOUND OUTPUT You can generate various melodies and sounds by linking the flash memory mounted on this unit to our model, PV-632 (MULTI-VOICE FILE). - AC POWER OUTPUT CONTROL When PW-642 and other equipment are connected via the AC outlet terminal of PW-642, you can turn ON/OFF the AC outlet button in the front panel and manually control ON/OFF of the AC power connected to other device. - BACK-UP POWER You can continue to maintain the time counter for about a week though the inner back-up even though AC power turns off with current time set. There is no need of readjusting time even though AC power is applied. - MEASURE AGAINST POWER FAILURE A separate memory is used to prevent data extinguishment due to power failure or other unstable power. - AUTOMATIC RETURN In programming data using a key button on the front side of PW-642 without using a PC, no pressing any button is recognized as cancel of program entry to return to normal operation status. - AC POWER OUTPUT TIME ADJUSTMENT You can adjust the AC power output time of PW-642 by 1~20sec to prevent time delay from occurring in the interface with the outside power amp. - KEY LOCK You can protect reservations and userʼs setting. |
|
|
| | PW - 642 | Input Channel (Balanced) | 5CH | Output Channel (Balanced) | 4CH | Output Level | Maximum 1v | AC Power Output 1 | Maximum 500W | AC Power Output 2 | Maximum 30 w | Data Preservation Time | 7 days and more | Melody Time (15 settings total - 247 seconds) | No.1 | 2 seconds | No.2 | 3 Seconds | No.3 | 3 Seconds | No.4 | 5 Seconds | No.5 | 5 Seconds | No.6 | 7 Seconds | No.7 | 7 Seconds | No.8 | 10 Seconds | No.9 | 10 Seconds | No.10 | 15 Seconds | No.11 | 20 Seconds | No.12 | 30 Seconds | No.13 | 30 Seconds | No.14 | 40 Seconds | No15 | 60 Seconds | Operation Temperature | -10°C ~+ 40°C | Power Source | 100- 120 VAC or 220 -240VAC; 50/60 Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 10W | Weight(SET) | 5.7Kg/12.6Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | ※ Specifications and design subject to change without notice. | | | |
| RM-200M - Five/ten zone console for VM-2120/2240 amplfiers
The RM-200M Remote Microphone that allows announcements to be made to any speaker zone and emergency announcements to all zones on a system with the VM-2120/2240 system management amplifiers.
These announcements can be made live or pre-recorded announcements
can be activated. The remote microphone is connected by cable to the
RM-210 Remote Microphone Extension unit.
SPECIFICATIONS:
Power Requirement |
24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.) |
Distortion |
Less than 1% |
Frequency Response |
100 - 10,000 Hz |
Distortion |
Less than 1% |
Signal-to-Noise Ratio |
More than 60 dB |
Audio Output |
0 dB*1, 600 O, balanced |
Microphone |
Unidirectional electret condenser microphone, gooseneck type. |
Speaker Zone Control |
Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast |
Emergency Broadcast |
Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch |
Voice Announcement Board Control |
Activation of 5 messages*2 |
Number of Connectable Units |
Up to 4 |
Communication System |
RS-485 |
Volume Control |
Microphone volume control |
Connection Cable and Connector Category |
5 STP cable, RJ45 connector |
Communication Distance |
800 m maximum in total |
Finish |
ABS resin |
Dimensions |
190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded) |
|
*1 0 dB = 1 V
*2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier. |
|