Content |
NT2-A - ?The Legend Continues? Multi Pattern 1? Condenser Microphone.
The new NT2-A carries on the tradition forged by the now legendary R?DE NT2.
A professional large capsule (1?) studio microphone incorporating three-position
pick-up patterns, pad and high pass filter switches conveniently located on the
mic body.
At the heart of the NT2-A is the Australian designed and manufactured HF1 dual
diaphragm capsule. The frequency and transient response of this new transducer
has been voiced to complement today?s modern recording techniques, and yet still
evoke the silky smooth character of the legendary microphones of the 50?s and 60?s.
These features provide the flexibility and superlative audio characteristics that make
the NT2-A one of the most versatile condenser mics available.
The NT2-A?s variable controls allow switching between Omni, Figure 8, and Cardioid
polar patterns. The three position high-pass filter provides a flat response or an 80Hz
and 40Hz high pass filter to be selected. Finally the microphones Pad can be switched
between 0 dB, -5dB and -10dB. The NT2-A comes in a soft pouch with an M2 stand mount.
SPECIFICATIONS:
Features:
The Australian designed and manufactured HF1 1? edge terminated, gold sputtered, dual
5 um diaphragm capsule. 3-position variable polar pattern: Omni, Cardioid & Figure 8; all
controlled on the mic. 3-position variable high-pass filter: Flat, 80 Hz or 40 Hz. 3-position
variable pad: 0 dB, -5 dB or -10 dB. Ultra low noise, transformerless SMT circuitry. Wide
dynamic range. High strength heat-treated steel mesh head. Durable satin nickel finish.
Internal capsule shock mounting. Supplied complete with soft pouch and clip. Designed
and manufactured in Sydney, Australia.
Operation power:
The NT2-A is designed to operate from phantom power to the P48 standard. The NT2-A will
operate between 44V and 52V applied with positive polarity to pin 2 and pin 3 of the output
XLR connector.
Operation output impedance:
The NT2-A will operate satisfactorily into a load impedance as low as 1 kΩ. If a load below this
is used, the output signal level will be reduced. The NT2-A output is balanced between pin 2 (hot)
and pin 3 (cold). Pin 1 is ground.
Acoustic principle: Externally polarized 25 mm (1?) dual diaphragm.
Directional pattern: Multi-pattern
Frequency range: 20 Hz ~ 20 000 Hz
Output impedance: 200 Ω
Signal noise ratio din iec 651:
87 dB (1 kHz rel 1 Pa; per IEC651, IEC268-15)
Equvalent noise: 7 dBA SPL (per IEC651, IEC268-15)
Maximum spl:
147 dB (@ 1% THD into 1 kΩ); 157 dB (@ 1% THD into 1 kΩ) - pad at maximum
Sensitivity: -36 dB re 1 Volt/Pascal; (16 mV @ 94 dB SPL) +/-2 dB
Dynamic range din iec 651: 140 dB (per IEC651, IEC268-15)
Power supply voltage: 48 Volts (P48)
Output connection:
3 pin XLR, balanced output between; pin 2(+) and pin 3(-); Pin 1 ground
Weight with battery: 860 grm | Behringer C-3 Dual-Diaphragm Studio Condenser Microphone
Introducing the Professional Condenser Microphone C-3 from BEHRINGER
Our latest dual-diaphragm condenser microphone C-3 is ideal for high-quality studio recording and live applications.
The selectable omnidirectional, cardioid, and figure-eight pickup patterns offer ultimate versatility needed to professionally record vocals and acoustic instruments. The C-3 holds a pressure-gradient transducer with a shock-mounted dual-diaphragm capsule. Its ultra-high sound resolution and flat frequency response rival those of microphones with much higher price tags. It also includes an LED that indicates phantom power operation and a gold-plated XLR output connector to ensure highest signal integrity. The C-3 comes with extensive accessories such as swivel stand and transport case.
The C-3 represents state-of-the-art technology at a price that is simply unheard of. |
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 13 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent noise level, CCIR1) | 23 dB | Equivalent noise level, A-weighted1) | 12 dB-A | Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) | 71 dB | Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) | 82 dB | Maximum SPL for THD | 110 dB | Maximum SPL for THD | 129 dB | Maximum output voltage for THD | -1 dBu | Dyn. range of the mic. amplifier /A-weighted, 0.5 %2)) | 98 dB | Dyn. range of the mic. amplifier /A-weighted, 5 %2)) | 117 dB | Supply voltage (P48, IEC 61938) | 48 V ± 4 V | Current consumption (P48, IEC 61938) | 3.2 mA | Matching connector | XLR 3F | Weight | 825 g | Diameter | 78 mm | Length | 165 mm |
1) According to IEC 60268-1; CCIR-weighting according to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
2) Measured as equivalent el. input signal |
|
|
The CK-7 houses a 35mm gold-sputtered thin Mylar capsule. The CK-7 uses high grade Polystyrene and Metalized Polypropylene capacitors in the audio path. This represents a commitment to quality, as these normally are the type of "upgrade" components that are implemented by microphone modders/hot-rodders! Any studio can proudly offer the CK-7 as a vocal mic or utility condenser due to its versatility...It exudes class visually as well as sonically.
Manufactured using the finest materials yielding a very solid feel, superb structural integrity and rugged reliability. The versatile CK-7 mic is able to produce professional results with a clean sonic character. The included Custom Retro Shockmount is superb in allowing a precise positioning of the mic while inhibiting the transfer of unwanted vibrations up into the mic. This isolation allows for superior professional results. The 3 patterns allow the CK-7 to be used in a variety of situations.
The cardioid pattern is generally best used on vocals and single instruments. The omni mode works well in incorporating some room sound into the track. The figure 8 pattern allows 2 vocalists to use the mic at the same time from opposite sides. The CK-7 has separate -10 dB pad & 80 Hz LF roll off switches....The -10dB attenuation switch can be engaged when miking very high SPL sources to keep from overloading the electronics. The 80Hz high-pass filter switch can be engaged to reduce rumble and to keep unwanted low frequencies from "muddying up" the track.
Applications.
studio vocals, acoustic guitar, mandolin, drum overheads, piano, room mic
Specifications
Type: True Condenser
Polar Pattern(s): Cardioid , Omni , Figure 8
Capsule: Dual-sided 35mm center-terminated gold-sputter Mylar (6 micron)
Frequency Response: 20-20,000 Hz +/- 3dB
Output Impedance: |
Rode's new NTK has the quality and warmth demanded from a tube mic.
With the large 1 in. capsule gold-plated membrane and twin triode tubes
(hand graded and selected), Rode is again setting the standard for value.
This is a tube mic designed exclusively for recording professionals who
want what only the best can offer.
Features:
Dynamic range of 47dB
Ultra low noise of only 12dB
Internal capsule shock mounting
Cardioid polar pattern
20Hz - 20kHz frequency response
Includes a power supply, 30 ft. cable, and stand adapter
Technical Description:
Capsule: Externally polarised 1 in. pressure-gradient condenser
Active Electronics: Unity-gain closed-loop impedance converter;
vacuum-tube input with bipolar buffering
Pickup Pattern: Cardioid
Frequency Response: 20Hz - 20kHz (+/-6dB)
Output Impedance: 200 ohms (100 ohms per leg)
Sensitivity: -38dB re 1V/Pa (12mV @ 94dB SPL) +/-1dB
Equivalent Noise: 12dB SPL (A-weighted per IEC268-15) +/-2dB
Maximum Output: > +29dBu (@ 1kHz, 5% THD into 1k (load)
Dynamic Range: > 147dB (A-weighted, per IEC268-15)
Maximum SPL: > 158dB SPL (@ 1kHz, 5% THD into 1k (load)
Signal/Noise Ratio: > 82dB (A-weighted, per IEC268-15)
External power supply: 100-120V/200-240V AC (user selectable)
50Hz/60Hz, 25VA maximum
Packed Weight: 4.53 kg (Mic only 760 gm)
Accessories included:
Power Supply
30 ft (10 m) Multicore Cable
M2 Standmount plus 3/8-5/8 in. Thread Adapter
Optional Extras: SM2 Shockmount
|
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Omnidirectional, wide angle cardioid, cardioid, hypercardioid, figure-8 plus one intermediate position each | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 34/47/62 mV/Pa* | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 28/25/23 dB* | Equivalent SPL DIN/IEC 651 | 16/13/11 dB-A* | S/N ratio CCIR 468-3 | 66/69/71 dB* | S/N ratio DIN/IEC 651 | 78/81/83 dB* | Typical SPL (tube characteristic) | K | Maximum output voltage | 18 dBu | Dynamic range of the microphone amplifier cardioid DIN/IEC 651 for | 101 (121) dB | Powering | Power supply N 149 | Matching connectors | Microphone DIN 8F, Power supply XLR 3F | Weight | 730 g | Diameter | 70 mm | Length | 201 mm |
* Omnidirectional / cardioid / figure-8
|
Reviews
There are no reviews yet.