Content |
26 AWG stranded (19x38) bare copper conductor, polyethylene insulation, individually shielded with BC ?French Braid?, each quad w/26 AWG TC drain wire, color-coded PVC inner jacket w/overall PVC jacket and 20 AWG TC drain wire. PHYSICAL CHARACTERISTICS : CONDUCTOR : Number of Quads: 2 Total Number of Conductors: 8 AWG: 26 Stranding: 19x38 Conductor Diameter: .020 in. Conductor Material: BC - Bare Copper INSULATION : Insulation Material: PE - Polyethylene Insulation Diameter: .045 in. INNER SHIELD : QUAD : Quad Shield Material Type: French Braid Quad Shield Material: BC - Bare Copper Quad Shield %Coverage: 95 % INNER SHIELD DRAIN WIRE - QUAD : Quad Shield Drain Wire AWG: 26 Quad Shield Drain Wire Stranding: 7x38 Quad Shield Drain Wire Conductor Material: TC - Tinned Copper INNER JACKET : Inner Jacket Material: PVC - Polyvinyl Chloride Inner Jacket Diameter: .157 in. Inner Jacket Insulation Resistance: Brown, Red Inner Jacket Color Code Chart: Number Color 1 Brown 2 Red QUAD : Quad Inner Jacket Color Code Chart: Number Color 1 Blue 2 White 3 Blue w/White Stripe Number Color 4 White w/Blue Stripe OVERALL CABLING : Overall Cabling Color Code Chart: Number Color 1 Brown 2 Red OUTER SHIELD : Outer Shield Drain Wire AWG: 20 Outer Shield Drain Wire Stranding: 19x32 Outer Shield Drain Wire Conductor Material: TC - Tinned Copper OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .458 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -40°C To +60°C Bulk Cable Weight: 85 lbs/1000 ft. Max. Recommended Pulling Tension: 89 lbs. Min. Bend Radius (Install): 4.75 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : EU CE Mark (Y/N): No EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 PLENUM/NON-PLENUM : Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 40 Ω Nom. Inductance: .21 ?H/ft Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 39.2 pF/ft Nom. Cap. Between Cond. in a Quad Config. @ 1 KHz: 57.4 pF/ft Nominal Velocity of Propagation: 66 % Nom. Conductor DC Resistance @ 20 Deg. C: 36 Ω/1000 ft Nom. Inner Shield DC Resistance @ 20 Deg. C: 6.8 Ω/1000 ft Max. Operating Voltage - UL: 100 V RMS Max. Recommended Current: 1 Amp per conductor @ 25°C Other Electrical Characteristic 1: 2/c 22 AWG equivalent DCR when connected to a 3-pin XLR
NOTE:Price per meter |
A P P L I C A T I O N Analogue audio Any analogue audio transmissions as well in fixed installations as on stage or broadcast These highly flexible multi-pairs are destined to mobile applications P R O D U C T A D V A N T A G E S High flexibility Transmission on important lengths due to 0,22 mm2 Facility of wiring thanks to conductors cross section colored and numbered pairs T E C H N I C A L D A T A NO. OF CONDUCTORS: No. x 2 x 0,22 mm2 Bare copper COMPOSITION: 28 x 0,10 mm CONDUCTOR INSULATION: Polyolefin SHIELDING BY PAIR: Bare copper spiral COLOR OF PAIR: See board JACKET: Black PVC PACKAGING: Per m SUITABLE PLUG: XLR, jack, cinch PRICE PER METER
| Adam Hall Cables 4 STAR HPD 325 Hybrid Cable Power & DMX 3 x 2.5 mm² & 2 x 0.22 mm². Price per meter
Type
Power / Signal Cable
Temperature range
-20 - 70 °C
Power
Number of internal conductors
3
Center conductor cross section
2.5 mm²
Center conductor construction
96 x 0.10 mm
Center conductor material
OFC
DMX
Number of inner conductors 2
2
Center conductor cross section 2
0.22 mm²
Center conductor construction 2
7 x 0.20 mm
Center conductor material 2
OFC
Shield
Aluminium foil, Copper spiral coil shield
Conductor resistance 2
85 ohm/km
| Adam Hall Cables 4 STAR HPA 325 Hybrid Cable Power & Audio 3 x 2.5 mm² & 2 x 0.22 mm². Price per meter
General
Type
Power / Signal Cable
Temperature range
-20 - 70 °C
Power
Number of internal conductors
3
Center conductor cross section
2.5 mm²
Center conductor construction
96 x 0.10 mm
Center conductor material
OFC
Audio
Number of inner conductors 2
2
Center conductor cross section 2
0.22 mm²
Center conductor construction 2
28 x 0.10 mm
Center conductor material 2
OFC
Conductor resistance 2
55 ohm/km
|
A P P L I C A T I O N Analogue audio Fixed installations Audio transmissions in noisy environment Wiring in professional sound studios P R O D U C T A D V A N T A G E S Very good protection against electromagnetique interferences thanks to individually shielded pairs and overall shield T E C H N I C A L D A T A NO. OF CONDUCTORS: No. x 2 x 0,22 mm2 Tinned copper CONDUCTOR INSULATION: PE SHIELDING BY PAIR: Aluminium polyester foil + drain wire COLOR OF CONDUCTEUR: White / blue COLOR OF PAIR: By number OVERALLSHIELD: Aluminium polyester foil + drain wire JACKET: Black PVC PACKAGING: Per m SUITABLE PLUG: XLR, jacks PRICE PER METER
|
DAP-Audio PSC-211
Power/Signal Cable, price per m
Specifications
500M on spool price p/m Conductor drains Ø mm: OFC 20 x 0,10 (NF) & 3 x 1,5 (power) Conductor insulation: PE red+black & PVC black (power) Conductor insulation Ø: 1,3 mm (NF) Filler material: paper 1st shield: twisted copper NF 96 x 0,10 2nd shield: - Outer isolation: PVC 11mm, matte blue Conductor resistance: 80 Ohm/Km Shield resistance: 30 Ohm/Km Capacity Inner conductor: 60 pF/m Cap. Inner conduct. Shield/Inner conduct.: 78 pF/m Working temperature: -20~60 °C (min./max.) Working Voltage overflash: 30V Nom Impedance: 110 Ohm |
Reviews
There are no reviews yet.