Want to make sure that your trussing is aligned? Want to know the height of the venue? Want to know the volume of the room? No problem! Know it in a few moments with this Ultrasonic Distance Meter!
• Calculates area and volume • Laser to target the point from where you want to measure • Auto converts feet to meters • Backlight
Specifications
Measurement range: 0,6 to 15 m Accuracy: ± 0,5% ± 1 Digit Resolutions: 0,01 m Aperture angle: ±5° Power supply: 6F22(9V) x 1 Dimensions: 136 x 59 x 38 mm Weight: approx. 150 g (incl. battery)
|
Infrared thermometer introduction: ①fever reminder, guard your baby\'s health ②Infrared temperature measurement technology Avoid contact with baby skin and spread bacteria ③Large back lit display (multi-parameter display) ④50 groups of memory functions °C/°F switching function / low battery reminder function ⑤2 temperature measurement mode Object temperature, body temperature measurement mode switch, 3-color back light display different temperature display different colors. ⑥Measurement result reminder: At the end of the measurement, the speaker will make a sound, prompting to complete the measurement. ⑦Precision temperature probe German precision probes ensure accurate temperature measurement ⑧Low power consumption, energy saving and envirronmental protection Powerred by 2 AAA batteries, no measurement 30 S automatic shutdown.
Display: LCD Digital
Way of working: Infrared
Alarm function: Three-color alarm
Operating mode: Human body and objects
shape: Handheld Gun shape
Battery voltage: DC 3 V (2 AAA alkaline batteries)
Measuring range: 34.0 ℃ ~ 43.0 ℃
Measurement accuracy: 42.0 ℃: ± 0.3 ℃ 35.0 ° C to 42.0 ° C: ± 0.2 ° C
Measuring distance: 5 ~ 15 cm
Measurement interval: about 6 seconds
Three-color back light Surface temperature mode:
Below 37.5 ℃ is green
37.6 ° C to 38.0 ° C is yellow
38.1 ℃ above is red
Automatic shutdown: ≦ 20 seconds
Storage: -20 ℃ ~ 45 ℃, relative humidity: ≦ 85% |
The MiniSPL is the perfect accessory to the Acoustilyzer & Minilyzer for
acoustical measurements.
The MiniSPL is a battery powered measurement microphone. Together
with the Acoustilyzer or Minilyzer, it forms an acoustical analyzer and integrating
sound level meter. Additionally it may be operated as a stand-alone microphone
e.g. connected to a balanced audio-line, a microphone-input or a sound-card.
Product-details
? Battery powered
? Factory-set sensitivity
? No phantom power required
? 1/2" microphone, class 2 acc. IEC 61672
? Omni-directional
? Supplied with mic clamp, wind protection
? Typical frequency response included
MiniSPL together with Acoustilyzer:
? SPL Meter / RTA
? Reverberation Time RT60
? Delay Time
? FFT Analyzer
? Speech Intelligibility STI-PA
MiniSPL together with Minilyzer:
? Measurements: SPL, min./max., Leq
? 1/3rd octave spectrum analyzer |
The PMBL is a 2 channel passive line level merge box. Each channel has 2 balanced XLR/f inputs. The input signal is merged via a resistor network to a XLR/m output.The top side input is transformer isolated. Possible applications might be the routing of two mixing desks to one power amp or mixing a stereo signal down to mono. Our transformer technology allows for an unbalanced top side input to be sent out balanced.
Specifications:
- Each Channel: Input 1 transformer balanced XLR/f. Symmetrically decoupled through resistors
- Total ohmic value: 2 K Maximum level for THD
|
ACOUSTILYZER
The Acoustilyzer AL1 functionality complements and expands the ML1
Minilyzer with a new and comprehensive set of acoustical measurement
functions.
The optimized combination of electrical and acoustical features creates
the perfect all in one tool for sound/systems contractors, installers and
multi-media specialists. The Acoustilyzer AL1 is available as a palm-sized
portable acoustical analyzer or as firmware for Minilyzer owners with optional
available STI-PA measurement functionality.
Required Accessories:
The AL1 requires a measurement microphone for acquiring acoustical signals.
NTI offers the following microphones:
- MiniSPL, class 2 acc. IEC 61672
- M2010, class 1 frequency response (ext. phantom power supply required)
Product Details
Sound Pressure Level: Leq, short-time Leq , LE, Lmin, Lmax,
Real Time Analyzer: 1/1 or 1/3 octave band resolution SPL/LEQ display per
band, max - min display
Zoom FFT: Actual level and Leq, full band up to 0.7Hz resolution
Reverberation Time: RT60 with 1/1 octave band resolution, confidence indicator,
according to ISO3382
Delay Time: Propagation delay between electrical and acoustical signal (built in mic),
resolution: 0.1ms
STI-PA (optional): Single value STI or CIS test result, modulation indices display,
individual band level results, error indicator, amplitude weighting acc. IEC 60268-16
release 2003
Electrical: Level RMS, THD+N, Polarity
Measurement microphone: Required for acquiring acoustical signals, NTI offers MiniSPL
or M2010 measurement microphones
| With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power "pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics.
SPECIFICATIONS:
- Input: 2 x XLR/f balanced
- Nominal impedance: 200 Ω
- Output 1 x XLR/m balanced
- Load impedance >200 Ω
- Symmetrically decoupled through resistors
- Total ohmic value: 200 ohms
- Typical attenuation: 6 dB
- Housing: metal casing 110 x 73 x 42 mm
|