Content |
Infrared thermometer introduction: ①fever reminder, guard your baby\'s health ②Infrared temperature measurement technology Avoid contact with baby skin and spread bacteria ③Large back lit display (multi-parameter display) ④50 groups of memory functions °C/°F switching function / low battery reminder function ⑤2 temperature measurement mode Object temperature, body temperature measurement mode switch, 3-color back light display different temperature display different colors. ⑥Measurement result reminder: At the end of the measurement, the speaker will make a sound, prompting to complete the measurement. ⑦Precision temperature probe German precision probes ensure accurate temperature measurement ⑧Low power consumption, energy saving and envirronmental protection Powerred by 2 AAA batteries, no measurement 30 S automatic shutdown.
Display: LCD Digital
Way of working: Infrared
Alarm function: Three-color alarm
Operating mode: Human body and objects
shape: Handheld Gun shape
Battery voltage: DC 3 V (2 AAA alkaline batteries)
Measuring range: 34.0 ℃ ~ 43.0 ℃
Measurement accuracy: 42.0 ℃: ± 0.3 ℃ 35.0 ° C to 42.0 ° C: ± 0.2 ° C
Measuring distance: 5 ~ 15 cm
Measurement interval: about 6 seconds
Three-color back light Surface temperature mode:
Below 37.5 ℃ is green
37.6 ° C to 38.0 ° C is yellow
38.1 ℃ above is red
Automatic shutdown: ≦ 20 seconds
Storage: -20 ℃ ~ 45 ℃, relative humidity: ≦ 85% |
The PMBL is a 2 channel passive line level merge box. Each channel has 2 balanced XLR/f inputs. The input signal is merged via a resistor network to a XLR/m output.The top side input is transformer isolated. Possible applications might be the routing of two mixing desks to one power amp or mixing a stereo signal down to mono. Our transformer technology allows for an unbalanced top side input to be sent out balanced.
Specifications:
- Each Channel: Input 1 transformer balanced XLR/f. Symmetrically decoupled through resistors
- Total ohmic value: 2 K Maximum level for THD
|
Cable Tester ACT-100
The Alphaton active remote cable tester can be used for testing either normal short cables or long ones, especially mufticores, wkh connectors not being accessible at one time. The tester is especially suded for fixed installations where cables can not be tested with a standard type cable tester or Ohm meter. Either symmetric and unsymmetric cables can be tested. “Cold" solderings and junction resistances are displayed by color or luminosity changes in three color LED Display. The imprinted fault table incorporates alt important fault conditions, indeed not all possible ones due to their reiatively large number. In case the display is in a state which cannot be found on the imprinted table, it can be looked up in the user's manual. In any case, however, the cabie is in aquite unusable state and should be repaired or replaced.The Alphaton cable tester has a SEND and a REMOTE section. The REMOTE sectionconsistsof two recessed mounted XLR type male or female connector and a stereo phone jack at the right hand side of the tester. Additionally, a separate REMOTE plug is delivered togetherwith the active remote cable tester for testing long cables in fixed installations.
|
ARTSOUND A8862 LASERGRIP THERMOMETER
Temperature range: -32 C - 550 C Accuracy: 1,5% Power supply: 9V Weight: 258gr
|
Minilyzer ML1 is the state-of-the-art analog audio meter that fits
into the palm of your hand.
It provides you with a comprehensive set of functions essential
for the analysis of professional audio systems.The powerful Minilyzer
continuously measures the audio signal and displays the desired
results with all complementary information on an illuminated hi-res
graphical LC-Display.
The Minilyzer and the MiniSPL form a comprehensive integrating
sound level meter.
MiniLINK, the USB interface for the Minilyzer allows documentation
and data acquisition of all ML1 functions in conjunction with the easy
to use MiniLINK PC application. MiniLINK supports online data logging
up to several days.
Product-details
Measurement functions:
Level RMS, Relative
Sound Pressure Level
Distortion Analyzer (THD+N), k2 - k5 harmonics
VU & PPM Meter
Speaker Polarity Test(for all speaker types)
Signal Balance Error
Frequency-/Time-Sweep Recording
1/3rd Octave Spectrum RMS & SPL
Scope
| Tests XLR, 1/4 in., 1/8 in., TT, RCA and MIDI connectors.
The intelligent, CPU-controlled CT100 accepts virtually any connector type:
XLR, mono and TRS phone (1/4 in., 1/8 in., TT), RCA and MIDI. It shows
which input pin is connected to which output pin. Separate LEDs indicate
proper shield connection and phantom power presence. The CT100 also
offers an installed cable test mode and a continuity check plus a test tone
generator.
Features
3 modes: cable test mode, installed cable test mode, and test tone mode
Accepts XLR, mono and stereo TRS phone (1/4 in., 1/8 in., TT),
RCA and MIDI Connectors
Continuity check
Intermittent detect
Phantom power detect
Grounded shield detect
Test tone generation (1 kHz and 440 Hz)
Battery operation (requires 2 AA alkaline batteries) |