Content | Replacement stylus for AT91 cartridge.
The ATN91 is also compatible stylus for CN5625AL and AT90 discontinued cartridges.
The ATN91 is also upgrade replacement styli for AT3600L.
The tracking force of AT3600L equipped with ATN91 is 2g, do not upgrade from ATN3600L to ATN91 when your tonearm does not allowed tracking force adjustment. | Stylus 2M Blue
Technical data |
|
Frequency range |
20-25.000 Hz |
Frequency response |
20-20.000 Hz + 2 / - 1 dB |
Tracking ability at 315Hz at recommended tracking force *) |
80 µm |
Compliance, dynamic, lateral |
20 µm/mN |
Stylus type |
Nude Elliptical |
Stylus tip radius |
r/R 8/18 µm |
Equivalent stylus tip mass |
0,5 mg |
Tracking force range |
1,6-2,0 g (16-20 mN) |
Tracking force, recommended |
1,8 g (18 mN) |
Tracking angle |
20° |
Stylus colour |
Blue |
|
|
Recommended for following cartridges |
2M Blue |
*) Typical value | Ortofon 520MKII Stylus Technical Data
- Frequency range 20-23.000 Hz
- Frequency response 20-20.000 Hz + 2 / - 3 dB
- Tracking ability at 315Hz at recommended tracking force 70 µm
- Compliance, dynamic, lateral 25 µm/mN
- Stylus type Nude Elliptical
- Stylus tip radius r/R 8/18 µm
- Equivalent stylus tip mass 0,3 mg
- Tracking force range 1,25-1,75 g (12,5-17,5 mN)
- Tracking force, recommended 1,5 g (15 mN)
- Tracking angle 20°
- Stylus colour Black
- Recommended for following cartridges Series 520 Mkll, 520, 520 P
|
|
Genuine Original Stylus for OM 20, OM 20 Super, OMP20, LM 20, Concorde 20, TM 20
Nude Elliptical
|
Ortofon 530MKII Stylus Technical Data
Frequency range 20-25.000 Hz
Frequency response 20-20.000 Hz + 2 / - 3 dB
Tracking ability at 315Hz at recommended tracking force 80 µm
Compliance, dynamic, lateral 30 µm/mN
Stylus type Nude Fine Line
Stylus tip radius r/R 8/40 µm
Equivalent stylus tip mass 0,3 mg
Tracking force range 1,25-1,75 g (12,5-17,5 mN)
Tracking force, recommended 1,75 g (17,5 mN)
Tracking angle 20°
Stylus colour Black
Recommended for following cartridges Series 530 Mkll, 530, 530 P |
| Ortofon 310 Stylus Technical Data
- Frequency range 20-20.000 Hz
- Frequency response 20-18.000 Hz + 2 / - 3 dB
- Tracking ability at 315Hz at recommended tracking force 60 µm
- Compliance, dynamic, lateral 20 µm/mN
- Stylus type Elliptical
- Stylus tip radius r/R 8/18 µm
- Equivalent stylus tip mass 0,5 mg
- Tracking force range 1,25-1,75 g (12,5-17,5 mN)
- Tracking force, recommended 1,5 g (15 mN)
- Tracking angle 20°
- Stylus colour Grey
- Recommended for following cartridges Series 310 Universial
|
|