Content |
Designed for use as a high-quality talk-back, paging and dispatch microphone in entertainment, commercial and industrial applications, the U855QL features a versatile gooseneck design which allows for flexible positioning and dependable performance. Its tailored frequency response ensures excellent intelligibility in environments with excessive ambient noise. An XLRM-type connector insert at the base allows the microphone to be plugged directly into an XLRF-type panel jack or microphone cable.
- Designed for use as a high-quality talk-back, paging & dispatch microphone in entertainment, commercial and industrial applications
- Extremely rugged all-metal construction for long-lasting performance
- Quick-mount design with 3-pin XLRM-type connector insert at base plugs into any standard XLRF-type surface or cable connector
- Low-profile element provides uniform cardioid polar pattern with 120º acceptance angle
- Easy-to-adjust, rugged gooseneck permits quick positioning
- Frequency response tailored for excellent intelligibility in environments with excessive ambient noise
- Polar pattern reduces pickup of sounds from the sides and rear, improving isolation of desired sound source
- Protective screen reduces wind noise and "popping” when used extremely close
- Element: Dynamic
- Polar Pattern: Cardioid
- Frequency Response: 150-16,000 Hz
- Open Circuit Sensitivity: –53 dB (2.2 mV) re 1V at 1 Pa
- Impedance: 600 ohms
- Weight: 278 g (9.8 oz)
- Dimensions: 448.0 mm (17.64“) long,
30.0 mm (1.18“) head diameter,
19.0 mm (0.75“) base diameter
- Output Connector: Integral 3-pin XLRM-type
|
AKG GN 30 OC., 12 inch gooseneck for D.A.M.-microphone capsules, 3/8“-connector, programmable indicator LED, incl. 10ft. cable to open-end, black, for installations |
Features:
- Miniature cardioid condenser clamp-on microphone with shock mounted capsule
- Ideal for miking drums and percussions
- Including wireless direct adapter for easy use with AKG pocket transmitters
- Detachable microphone cable
- Integrated gooseneck
- Continuously adjustable vise type clamp
Recommended For:
- Drums
- Brass
- Recording
- Percussions
Standard Accessories:
- A400 adapter
- H518 Drum bracket
- Microphone bag
- W44 Windscreen
Specs:
- Polar pattern cardioid
- Frequency range 60 Hz to 20 kHz
- Sensitivity 5 mV/Pa (-46 dBV)
- Max. SPL 130/132 dB SPL (for 1%/3% THD)
- Equivalent noise level 31 dB(A)
- Signal/noise ratio (A-weighted) 63 dB
- Impedance = 2000 ohms
- Current consumption
|
Shure MX418D-C Gooseneck Cardioid Condenser Microphone
Microflex? Gooseneck microphones bring a whole new meaning to the word flexible with their fully adjustable gooseneck. Designed for easy replacement and available in cardioid, supercardioid and omnidirectional polar patterns, the interchangeable cartridges offer wide frequency response and accurate sound reproduction for a wide variety of applications such as houses of worship, courtrooms and conference centers. Plus, the condenser cartridges fit every model in the Microflex product line for enhanced convenience and consistent sound.
Microflex Gooseneck microphones are available in four models with a variety of heights and mounting styles to choose from. One model includes a silent mute switch with LED indicator, a Shure Microflex exclusive. And every Microflex Gooseneck features high sensitivity and balanced, transformerless output for maximum resistance to electromagnetic hum and RF interference, even over long cable runs.
Desktop Base with 10 foot Cable, Logic Functions, Programmable Switch and LED Indicator, Snap-Fit Foam Windscreen
Features:
Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum Interchangeable cartridges provide the right polar pattern for every application Balanced, transformerless output for increased immunity to noise over long cable runs Shock mount provides over 20 dB isolation from surface vibration noise Locking flange mount for permanently securing microphone to lecterns, pulpits, or conference tables Snap-fit foam windscreen Programmable on/off switch and LED on/off indicator (M412D/MX418D) New brighter LED improves visibility under strong ambient lighting M412D/MX418D) Logic input and output terminals for remote control or use with automatic microphone mixers M412D/MX418D) Supplied shock mount for more than 20 dB isolation from surface transmitted noise (MX412SW/MX418SE) Supplied threaded flange mount for permanently securing the microphone to a lectern, pulpit, or conference table (MX412SW/MX418SE)
Microphone Specifications: Frequency Response 50 to 17,000 Hz Output Impedance 180 ohms actual (EIA rated at 150 ohms) Sensitivity (At 1,000 Hz, open circuit voltage*) Cardioid: -35.0 dBV/Pa (17.8 mV) Supercardioid: -33.5 dBV/Pa (21.1 mV) Omnidirectional: -27.5 dBV/Pa (42.2 mV) All values -12 dB at 0 gain; *1 Pascal = 94 dB SPL Maximum SPL (1 kHz at 1% THD, 1 k ohm load) Cardioid: 124.2 dB Supercardioid: 122.7 dB Omnidirectional: 116.7 dB All values +6 dB at 0 gain Equivalent Output Noise (A-weighted) Cardioid: 28.0 dB SPL Supercardioid: 26.5 dB SPL Omnidirectional: 20.5 dB SPL Signal to Noise Ratio (referenced at 94 dB SPL) Cardioid: 66.0 dB Supercardioid: 67.5 dB Omnidirectional: 73.5 dB Dynamic Range at 1 k ohm load 96.2 dB 100 dB at 0 gain Common Mode Rejection 45.0 dB minimum Preamplifier Output Clipping Level (1% THD) -6.0 dBV (0.5 V) -12 dBV at 0 gain Polarity Positive sound pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of output connector. Power Requirements 11 to 52 Vdc phantom, 2.0 mA Environmental Requirements Operating Temperature Range: -18 to 57 degrees C (0 to 135 degrees F) Relative Humidity: 0 to 95% |
- Miniature cardioid condenser clamp-on microphone with shock mounted capsule, ideal for miking drums and percussions plus brass
- For use with the B 29 L battery power supply, MPA V L phantom power adapter, or PT 40 or PT 400 transmitters (AKG WMS bodypack transmitters)
- Includes an AKG W 44 Windscreen, an AKG A 518 stabilizer knee, a 5-ft. (1.5-m) plug-in connecting cable with 3-pin mini XLR connector, an A 400 adapter for attaching a PT 40 or PT 400 bodypack transmitter and a protective case
- Integrated gooseneck
- Continuously adjustable vice type clamp
- Type: pre-polarized condenser microphone
- Polar pattern: Cardioid
- Frequency range: 60 Hz to 20,000 Hz
- Sensitivity at 1 kHz: 5 mV/Pa (-46 dBV re 1 V/Pa)
- Impedance: = 200 ohms
- Recommended load impedance: = 2000 ohms
- Max. SPL for 1%/3% THD: 130/132 dB SPL
- Equivalent noise level: 31 dB(A) to DIN 45412
- Cable length / Connector: 1.5 m (5 ft.) / 3-pin mini XLR
- Finish: Matte black
- Size (microphone only): length: 200 mm (7.9 in.), max. width: 47 mm (1.9 in.)
- Net weight (microphone and cable): C 518 M: 220 g (7.8 oz.), C 518 ML: 110 g (3.9 oz.)
- Shipping weight: C 518 M: 450 g (15.9 oz.), C 518 ML: 330 g (11.7 oz.)
|
Polar pattern Cardioid
Frequency range 70 to 18,000 Hz
Max. SPL 125 dB (for 1% THD)
Equivalent noise level 73 dB
Impedance =2,000 ohms
Supply voltage 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)