The Zone Controllers offer extended utility to the DriveRack®and ZonePro families. The nine Zone Controllers use analog DC voltage to provide logic control ranging from zone source selection, volume and muting, to program or scene selection and fire safety muting. Wired with readily available and affordable CAT5 cable with universally accepted rj-45 connectors at distances up to 1000 ft, the ZC Zone Controllers offer simple yet elegant solutions to the contractor.
The ZC-1 provides programmable remote volume control for the DriveRack 260, 220i and the ZonePro 640 and 641. The ZC-2 offers programmable volume and mute control for the DriveRack 220i, 260 and the ZonePro 640 and 641. The ZC-3 can function as a program selector for the DriveRack 260 and 220i; in addition it can be used for as a source selector, page steering control, or a scene selector for the ZonePro products. The ZC-4 provides program change capability from contact closures for the DriveRack 220i and 260; it can also provide source selection, page steering, or scene selection for the ZonePro 640 and 641. The ZC-6 is a programmable volume control for the ZonePro 640 and 641. The ZC-7 is a programmable push -to-talk page assignment controller for the ZonePro devices. The ZC-8 provides both programmable source selection and volume control to the ZonePro 640 and 641. The ZC-BOB allows "home run” or parallel wiring to the DriveRack and ZonePro devices. The ZC-FIRE is a dedicated fire safety interface for the ZonePro products that allows selection of either system mute or scene selection upon being triggered by either a relay or control voltage from the fire safety system.
• Programmable Volume Control
• Program or Scene Selection
• Programmable Contact Closure Interface
• Up to 1000 ft. on CAT 5 Cable
• Programmable Push-To-Talk Paging
• Programmable Source Selection |
*Convenient Priority Broadcasting
*Convenient Installation and Construction without ID Setting
*RS-422 Communication between RM-500 and Z-500
*21 Zone Paging Selection
*Output Signal Level Display
*Multi Chime Options
*Weight: 1.6kg/3.5Ib
*DImensions(W×H×D): 200×206×70mm/7.9×8.1×2.8in
|
- CONSIDERATION OF USERʼS CONVENIENCE NUMERIC buttons and various function buttons are separated for timer program enter and convenience in use so that the user can easily operate. - ADOPTION OF VACUUM FLUORESCENT DISPLAY PANEL Adopting a vacuum fluorescent display of a dot matrix method enables to check operation status of each function at a glimpse. - PROGRAMMING USING A PC You can easily execute reservation setting thorough management program by connecting a PC to the RS-232C port. - VARIOUS MELODY AND SOUND OUTPUT You can generate various melodies and sounds by linking the flash memory mounted on this unit to our model, PV-632 (MULTI-VOICE FILE). - AC POWER OUTPUT CONTROL When PW-642 and other equipment are connected via the AC outlet terminal of PW-642, you can turn ON/OFF the AC outlet button in the front panel and manually control ON/OFF of the AC power connected to other device. - BACK-UP POWER You can continue to maintain the time counter for about a week though the inner back-up even though AC power turns off with current time set. There is no need of readjusting time even though AC power is applied. - MEASURE AGAINST POWER FAILURE A separate memory is used to prevent data extinguishment due to power failure or other unstable power. - AUTOMATIC RETURN In programming data using a key button on the front side of PW-642 without using a PC, no pressing any button is recognized as cancel of program entry to return to normal operation status. - AC POWER OUTPUT TIME ADJUSTMENT You can adjust the AC power output time of PW-642 by 1~20sec to prevent time delay from occurring in the interface with the outside power amp. - KEY LOCK You can protect reservations and userʼs setting. |
|
|
| | PW - 642 | Input Channel (Balanced) | 5CH | Output Channel (Balanced) | 4CH | Output Level | Maximum 1v | AC Power Output 1 | Maximum 500W | AC Power Output 2 | Maximum 30 w | Data Preservation Time | 7 days and more | Melody Time (15 settings total - 247 seconds) | No.1 | 2 seconds | No.2 | 3 Seconds | No.3 | 3 Seconds | No.4 | 5 Seconds | No.5 | 5 Seconds | No.6 | 7 Seconds | No.7 | 7 Seconds | No.8 | 10 Seconds | No.9 | 10 Seconds | No.10 | 15 Seconds | No.11 | 20 Seconds | No.12 | 30 Seconds | No.13 | 30 Seconds | No.14 | 40 Seconds | No15 | 60 Seconds | Operation Temperature | -10°C ~+ 40°C | Power Source | 100- 120 VAC or 220 -240VAC; 50/60 Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 10W | Weight(SET) | 5.7Kg/12.6Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | ※ Specifications and design subject to change without notice. | | | |
|
- PRIORITY CONTROL It controls the priority of emergency, timer, remote1, remote2, main(normal). - AUTO FIRE SENSOR The fire alarm will be given automatically to the designated areas by detecting fire sensor input. - SPEAKER SWITCHING ON EMERGENCY OR NORMAL(MAIN) You can control the speaker relay on emergency or normal(main) mode by using the speaker switch on front panel. - DISPLAY STATUS You can easily check the priority status. - 2 AND 3 WIRE SPEAKER LINE SYSTEM You can control the speaker line on the 2 wire system or 3 wire system. - EXTENSION FUNCTION You can easily expand by connecting additional ECS-616.
ECS-616 | Priority Control | Emergency >Timer > Remote1 > Remote2 > Main | Link in/ out Interface | RS-422(19200bps,Data 8bits,Stop 1bit, Non Parity bit, Start1bit) | Link in/ out interface Distance | 1.2 km | Operation Temperature | -10 °C ~+ 40 °C | Power Source | 24V DC | Power Consumption | 900mA | Weight | 4.8Kg/10.6Ib | Dimensions( W x H x D) | 482(W)x 88(H) x 380(D) mm / 19(W)x 3.5(H)x 15(D)in | ※ Specifications and design subject to change without notice. |
|
Emergency combination system. Ενσωματώνεται σε σύστημα συναγερμού φωτιάς. Ενσωματωμένο πυκνωτικό μικρόφωνο για Επείγουσα Αναγγελία, Εξωτερική αυτόματη αναγγελία με αρχείο φωνής, Επιλογέας δοκιμής. Ρύθμιση έντασης εξόδου, Βάρος 4,6kg. Διαστάσεις (WxHxD): 482X88X380mm |
| - SYSTEM POWER CONTROL It controls the power of the rack system over all working together with the PD-659. - AC OUTLET TERMINAL To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds. | | | | | PD- 658 | AC Outlet | Switched 2000W ⅹ3 | Operation Temperature | -10℃~+40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 10W | Weight(SET) | 4.6Kg/10.1 Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | | | |
|