– SYSTEM POWER CONTROL It controls the power of the rack system over all working together with the PD-659. – AC OUTLET TERMINAL To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds. PD- 658 AC Outlet Switched […]

 

Read more

– SYSTEM POWER CONTROL

It controls the power of the rack system over all working together with the PD-659.

– AC OUTLET TERMINAL

To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds.

PD- 658

AC Outlet

Switched 2000W ⅹ3

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied AC mains transformer depends on country requirements)

Power Consumption

10W

Weight(SET)

4.6Kg/10.1 Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

Weight 4.90 kg

Reviews

There are no reviews yet.

Be the first to review “INTER-M PD-658 SUB POWER DISTRIBUTOR”

Your email address will not be published. Required fields are marked *

Quick Comparison

INTER-M PD-658 SUB POWER DISTRIBUTOR removeINTER-M PD-659 POWER DISTRIBUTOR/CONTROL UNIT removeINTER-M PW-642 WEEKLY PROGR.TIMER 5IN/4OUT removeTOA AT-100UPR Attenuator with Relay 100 W removeJBL MTC 300T150 Transformer 70/100V removeINTER-M PF-602 Auto Blower remove
NameINTER-M PD-658 SUB POWER DISTRIBUTOR removeINTER-M PD-659 POWER DISTRIBUTOR/CONTROL UNIT removeINTER-M PW-642 WEEKLY PROGR.TIMER 5IN/4OUT removeTOA AT-100UPR Attenuator with Relay 100 W removeJBL MTC 300T150 Transformer 70/100V removeINTER-M PF-602 Auto Blower remove
Image
SKUPD-658PD-659PW-642AT-100UPRMTC 300T150PF-602
Rating
Price 178.99 incl. GR VAT 314.00 incl. GR VAT 335.00 incl. GR VAT 145.09 incl. GR VAT 102.00 incl. GR VAT 114.01 incl. GR VAT
Stock

In stock

In stock

In stock

Available on backorder

In stock

In stock

AvailabilityIn stockIn stockIn stockAvailable on backorderIn stockIn stock
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

- SYSTEM POWER CONTROL

It controls the power of the rack system over all working together with the PD-659.

- AC OUTLET TERMINAL

To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds.

PD- 658

AC Outlet

Switched 2000W ⅹ3

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied AC mains transformer depends on country requirements)

Power Consumption

10W

Weight(SET)

4.6Kg/10.1 Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

- SYSTEM POWER CONTROL

You can control the power of your system by using this model.

- AC AND DC POWER SUPPLY

You can distribute AC and DC power through the AC outlet and DC terminals on the rear panel.

- USE OF EMERGENCY POWER SUPPLY

For emergency equipment power supply, an extra DC terminal is provided.

- REMOTE CONTROL

You can control the system power by remote control function even though the power switch on front is off.

- AC AND DC VOLT METER

This model uses digital volt meter displays of AC and DC.

- OPERATING MODE DISPLAY

You can easily check the operating mode by LEDs, AC or DC operating and emergency power.

PD-659

AC Outlet

Switched 2000W ⅹ3

Unswitched 700W ⅹ1

Remote Control

1

DC Power Output

DC 24V 5A

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied ACmains transformer depends on country requirements)

Power Consumption

190W

Weight(SET)

6.2Kg/13.6Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

※ Specifications and design subject to change without notice.

- CONSIDERATION OF USERʼS CONVENIENCE

NUMERIC buttons and various function buttons are separated for timer program enter and convenience in use so that the user can easily operate.

- ADOPTION OF VACUUM FLUORESCENT DISPLAY PANEL

Adopting a vacuum fluorescent display of a dot matrix method enables to check operation status of each function at a glimpse.

- PROGRAMMING USING A PC

You can easily execute reservation setting thorough management program by connecting a PC to the RS-232C port.

- VARIOUS MELODY AND SOUND OUTPUT

You can generate various melodies and sounds by linking the flash memory mounted on this unit to our model, PV-632 (MULTI-VOICE FILE).

- AC POWER OUTPUT CONTROL

When PW-642 and other equipment are connected via the AC outlet terminal of PW-642, you can turn ON/OFF the AC outlet button in the front panel and manually control ON/OFF of the AC power connected to other device.

- BACK-UP POWER

You can continue to maintain the time counter for about a week though the inner back-up even though AC power turns off with current time set. There is no need of readjusting time even though AC power is applied.

- MEASURE AGAINST POWER FAILURE

A separate memory is used to prevent data extinguishment due to power failure or other unstable power.

- AUTOMATIC RETURN

In programming data using a key button on the front side of PW-642 without using a PC, no pressing any button is recognized as cancel of program entry to return to normal operation status.

- AC POWER OUTPUT TIME ADJUSTMENT

You can adjust the AC power output time of PW-642 by 1~20sec to prevent time delay from occurring in the interface with the outside power amp.

- KEY LOCK

You can protect reservations and userʼs setting.

PW - 642

Input Channel (Balanced)

5CH

Output Channel (Balanced)

4CH

Output Level

Maximum 1v

AC Power Output 1

Maximum 500W

AC Power Output 2

Maximum 30 w

Data Preservation Time

7 days and more

Melody Time

(15 settings total - 247 seconds)

No.1

2 seconds

No.2

3 Seconds

No.3

3 Seconds

No.4

5 Seconds

No.5

5 Seconds

No.6

7 Seconds

No.7

7 Seconds

No.8

10 Seconds

No.9

10 Seconds

No.10

15 Seconds

No.11

20 Seconds

No.12

30 Seconds

No.13

30 Seconds

No.14

40 Seconds

No15

60 Seconds

Operation Temperature

-10°C ~+ 40°C

Power Source

100- 120 VAC or 220 -240VAC; 50/60 Hz

(Supplied AC mains transformer depends on country requirements)

Power Consumption

10W

Weight(SET)

5.7Kg/12.6Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

※ Specifications and design subject to change without notice.

toa-at-100upr Build-in Attenuator with Relay
Toa - 100V installation


Build-in Attenuator with Relay 100 W / 100 V

The JBL MTC-300T150 150 Watt Transformer is intended for use with 70V or 100V distributed loudspeaker lines. It is ideally suited for the Control Series 300, especially the 300BB12 Backbox which includes a preinstalled mounting location.

- FAN FOR PA RACK

Auto fan operates when the inside temperature of PA RACK goes up.

- MANUAL OPERATING

When it's manual mode, the fan operates always regardless of temperature.

- AUTO OPERATING

When it's auto mode, the fan operates at 35°C.

PF- 602

Operation Selector Switch

Manual, Auto, Operating temperature

Fan

2 DC fans

Power Source

24VDC

Power Consumption

160mA

Weight

4Kg/8.8Ib

Dimensions( W x H x D)

482x 88 x 380 mm / 19 x 3.5 x 15in

※ Specifications and design subject to change without notice.

Weight4.90 kg6.20 kg5.70 kg1.00 kg1.80 kg4.00 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 4.90 kg
Weight 6.20 kg
Weight 5.70 kg
Weight 1.00 kg
Weight 1.80 kg
Weight 4.00 kg