T E C H N I C A L D A T A
DMX 512 CABLE
NO. OF CONDUCTORS: 2 x 2 x 0,34 mm2 Tinned copper – AWG22
CONDUCTOR INSULATION: PE
1ST SHIELDING: Aluminium foil + drain wire
2ND SHIELDING: Tinned copper braid
JACKET: Grey PVC
DIAMETER: 7 mm
POWER CABLE
NO. OF CONDUCTORS: 3 G 1.5 mm2 Bare copper
CONDUCTOR INSULATION: PVE
COLOUR CODING: Brown - Blue - Green / Yellow
ASSEMBLY
WEIGHT PER 1 KM: 255 Kg / km
PACKAGING: Per m
SUITABLE PLUG: XLR
DIAMMETER: 14mm
| 24 AWG stranded (42x40) HC BC conductors, Datalene? insulation, conductors cabled
with fillers, TC "French Braid" Shield (95% coverage), BC drain wire, PVC jacket.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Pairs: 1
Total Number of Conductors: 2
AWG: 24
Stranding: 42x40
Conductor Diameter: .024 in.
Conductor Material: BC - Bare Copper
INSULATION :
Insulation Material Trade Name: Datalene?
Insulation Material: FHDPE - Foam High Density Polyethylene
Insulation Diameter: .058 in.
Pair Color Code Chart:
Number Color 1 Red & Black
OUTER SHIELD :
Outer Shield Type: French Braid
Outer Shield Material: TC - Tinned Copper
Outer Shield %Coverage: 95 %
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG: 26
Outer Shield Drain Wire Stranding: Stranded
Outer Shield Drain Wire Conductor Material: BC - Bare Copper
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .211 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -20°C To +60°C
Non-UL Temperature Rating: 60°C
Bulk Cable Weight: 24 lbs/1000 ft.
Max. Recommended Pulling Tension: 41.5 lbs.
Min. Bend Radius (Install): 2.25 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CL2R
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
Other Specification: AES/EBU Digital Audio
FLAME TEST :
UL Flame Test: UL1666 Riser
PLENUM/NON-PLENUM :
Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 110 Ω
Nom. Inductance: 0.18 ?H/ft
Nom. Capacitance Conductor to Conductor @ 1 KHz: 12 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 26 pF/ft
Nominal Velocity of Propagation: 76 %
Nom. Conductor DC Resistance @ 20 Deg. C: 23.7 Ω/1000 ft
Nominal Outer Shield DC Resistance @ 20 Deg. C: 6.42 Ω/1000 ft
Nom. Attenuation (dB/100 ft):
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
.384 0.46
.706 0.67
.768 0.70
1.024 0.83
1.411 1.04
1.536 1.09
2.048 1.30
2.822 1.66
3.072 1.75
4.096 2.23
5.645 2.89
6.144 3.07
8.192 3.71
11.290 4.53
12.288 4.78
24.576 7.11
Max. Operating Voltage - UL: 300 V RMS
Max. Recommended Current: 2.75 Amps per conductor @ 25°C
NOTES :
Notes: Datalene? insulation features include low dielectric constant and a dissipation
factor for high-speed, low-distortion data handling. Physical properties include good crush
resistance and light weight. |
Combination DMX & Power cable, both housed in a robust, durable outer cable jacket. This cable will provide the power and control signal data for lights, mixing consoles and other DMX512 dependable units, consisting of 3 x power cables (1.5qmm each) and either one (Lightpower 1), two (Lightpower 2) or four (Lightpower 4) pairs of DMX512 cables. When using Lightpower 4, two of the DMX pairs can be used for transmission of intercom signals.
Product type
Bulk Cable
Type
Network / Signal Cable
Colour
black
Overall diameter
12 mm
Jacket material
PVC
Inner conductor 1
Inner conductor type
Mains supply line
Conductor cross-section
1.5 mm²
Conductor material
bare copper
Conductor construction
48 x 0.2 mm
Number of conductors
3
Inner conductor 2
Inner conductor 2 type
audio/DMX
Inner conductor 2 cross-section
0.14 mm²
Inner conductor 2 material
bare copper
Inner conductor 2 construction
36 x 0.07 mm
Number of inner conductors 2
2
Inner conductor 2 shielding material
Copper tin-plated
Inner conductor 2 shielding
spiral
Characteristic impedance inner conductor 2
110 Ohm(s)
Line resistance inner conductor 2
Inner conductor 2 capacitance
52 pF/m
Other features
DMX line shielded and insulated in pairs
PRICE PER METER
|
23 AWG solid .023" bare copper or bare copper-covered conductor, polyethylene insulation, bare copper braid shield (95% coverage), PVC jacket. PHYSICAL CHARACTERISTICS : CONDUCTOR : Number of Coax: 1 Total Number of Conductors: 1 RG Type: 59/U AWG: 23 Stranding: Solid Conductor Diameter: .023 in. Conductor Material: BC - Bare Copper INSULATION : Insulation Material: PE - Polyethylene Insulation Diameter: .146 in. OUTER SHIELD : Outer Shield Type: Braid Outer Shield Material: BC - Bare Copper Outer Shield %Coverage: 95 % OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .242 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -20°C To +80°C UL Temperature Rating: 80°C (UL AWM Style 1354) Bulk Cable Weight: 36 lbs/1000 ft. Max. Recommended Pulling Tension: 62 lbs. Min. Bend Radius (Install): 2.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CM CEC/C(UL) Specification: CM AWM Specification: UL Style 1354 (30 V 80°C) EU CE Mark (Y/N): No EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 FLAME TEST : UL Flame Test: UL1685 UL Loading SUITABILITY : Suitability - Indoor: Yes Suitability - Outdoor: Yes PLENUM/NON-PLENUM : Plenum (Y/N): N ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 75 Ω Nom. Inductance: .131 ?H/ft Nom. Capacitance Conductor to Shield: 20.5 pF/ft Nominal Velocity of Propagation: 66 % Nominal Delay: 1.54 ns/ft Nom. Conductor DC Resistance @ 20 Deg. C: 20.4 Ω/1000 ft Nominal Outer Shield DC Resistance @ 20°C: 2.9 Ω/1000 ft Nom. Attenuation: Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.) 1 .4 10 1.1 50 2.4 100 3.4 200 4.9 400 7.0 700 9.7 900 11.1 1000 12.0 Max. Power Rating: Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Max. Power Rating (W) 50 470 100 310 300 160 500 115 1000 76 Max. Operating Voltage - UL: 30 V RMS (UL AWM Style 1354); 300 V RMS Max. Operating Voltage - Non-UL: 1700 V RMS
NOTES : Notes: RG-59/U Type standard Analog Video Coax. CM Rated Version of 8241.
NOTE:Price per meter |
Cable construction: |
2 x 0,22 mm² |
Cable length: |
100 m |
Impedance: |
110 ohms |
Plug A: |
1 x no connector/cable only |
Plug B: |
1 x no connector/cable only |
Color: |
Black |
Dimensions: |
Diameter: Ø 6 mm |
Weight: |
4,79 kg |
|
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil? (100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip simultaneously, overall Beldfoil shield and 24 AWG TC drain wire. PHYSICAL CHARACTERISTICS :
CONDUCTOR : Number of Pairs: 16 Total Number of Conductors: 32 AWG: 24 Stranding: 7x32 Conductor Diameter: .024 in. Conductor Material: TC - Tinned Copper INSULATION : Insulation Material: PO - Polyolefin Nom. Insulation Wall Thickness: .008 in. Insulation Diameter: .040 in. Lay Length: 1.75 in. Twists/ft.: 6.85 Pair Color Code Chart: Red and Black INNER SHIELD : Inner Shield Material Trade Name: Beldfoil? Inner Shield Type: Tape Inner Shield Material: Aluminum Foil-Polyester Tape Inner Shield % Coverage: 100 % Inner Shield Drain Wire AWG: 24 Inner Shield Drain Wire Stranding: 7x32 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper INNER JACKET : Inner Jacket Material: PVC - Polyvinyl Chloride Inner Jacket Nominal Wall Thickness: .014 in. Inner Jacket Diameter: .111 in. Inner Jacket Color Code Chart: Number Color 1 Brown 2 Red 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White Number Color 10 Black 11 Tan 12 Pink 13 Gray/Brown 14 Gray/Red 15 Gray/Orange 16 Gray/Yellow OUTER SHIELD : Outer Shield Material Trade Name: Beldfoil? Outer Shield Type: Tape Outer Shield Material: Aluminum Foil-Polyester Tape Outer Shield %Coverage: 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG: 18 Outer Shield Drain Wire Stranding: 7x26 Outer Shield Drain Wire Conductor Material: TC - Tinned Copper OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride Outer Jacket Nominal Wall Thickness: .056 in. Outer Jacket Ripcord: Yes OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .628 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -35°C To +75°C Bulk Cable Weight: 177.3 lbs/1000 ft. Max. Recommended Pulling Tension: 286.4 lbs. Min. Bend Radius (Install): 6.5 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CM CEC/C(UL) Specification: CM EU CE Mark (Y/N): Yes EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 PLENUM/NON-PLENUM : Plenum (Y/N): N ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 50 Ω Nom. Inductance: .18 ?H/ft Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft Nominal Velocity of Propagation: 66 % Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft Max. Operating Voltage - UL: 300 V RMS Max. Recommended Current: 1.05 Amps per conductor @ 25°C |
Reviews
There are no reviews yet.