Content | TUV PL-L lamps are compact UVC (germicidal) lamps used in residential water and air disinfection units. The compact size of the lamp allows for a small system design and design flexibility. TUV PL-L lamps offer constant UV output over their complete lifetime, for maximum security of disinfection and high system efficacy. Thanks to the single-ended lamp base, lamp replacement is easy.
Product Features
- Short-wave UV radiation with a peak at 253.7 nm (UVC) for disinfection purposes
- Protective inside coating ensures constant UV output over the complete lifetime of the lamp
- Special lamp glass filters out the 185 nm ozone-forming radiation
- High Output versions contain wind-chill correction for improved performance in moving air and reducing amount of required lamps
- High Output versions for optimum UVC output per lamp length, allowing for reduction of system size
- Warning sign on lamp indicates that the lamp radiates UVC
Product Benefits
- Security of effective disinfection over the complete lifetime of the lamp
- High system efficacy because it is not required to over-design the purification system to maintain effectiveness of disinfection
Application
- Deactivation of bacteria, viruses and other micro-organisms
- Residential drinking water units
- Fish pond and process water units
- In-duct air treatment units
- Stand alone air purifiers
- Air disinfection systems in for example hospitals, universities and laboratories
Main Characteristics
System Description |
- |
Cap-Base |
2G11 |
Cap-Base Information |
4 Pins |
Bulb |
2xT16 |
Execution |
- |
Main Application |
Disinfection |
Useful Life (hr) |
9000 |
Colour Code |
TUV |
Colour Designation |
- |
Rated Lamp Wattage (W) |
36 |
Technical Lamp Power (W) |
36 |
Lamp Voltage (V) |
105 |
Lamp Current (A) |
0.44 |
UV-C Radiation (W) |
12.0 |
Base Face to Base Face A (mm) |
385 (max) |
Insertion Length B (mm) |
410 (max) |
Overall Length C (mm) |
415 (max) |
Diameter D (mm) |
38 (max) |
Diameter D1 (mm) |
18 (max) |
Order code |
628787 40 |
Full product code |
871150062878740 |
Full product name |
TUV PL-L 36W/4P 1CT |
Order product name |
TUV PL-L 36W/4P 1CT/25 |
Pieces per pack |
1 |
Packing configuration |
25 |
Packs per outerbox |
25 |
Bar code on pack - EAN1 |
8711500628787 |
Bar code on outerbox - EAN3 |
8711500628794 |
Logistic code(s) - 12NC |
927903404007 |
Net weight per piece (gr) |
104.000 |
| General Electric Par 56 WFL Long 240V-300W
Volts:240
Watts:300
Hours:2000H
Temperature:300K
Base:GX16D | Osram Par 64 CP61 Narrow(13x10) 240V-1000W
Areas of application
_ Events
_ Performances
_ Stage productions
Product family benefits
_ Easy lamp replacement
_ Flexible operating position
Product family features
_ The parabolic glass reflector and the front lens are fused together
_ High luminous intensity
_ Available in different beam angles to ensure high flexibility
Voltage (lamps): |
240 V |
Nominal wattage: |
1000 W |
Base: |
GX16d |
Lamp type: |
Halogen lamp; high voltage lamp; halogen bulb |
Lamp specification: |
Dimmable
Hot restrike |
Beam angle: |
14° |
Color of light: |
White |
Color temperature: |
3100K |
Construction: |
PAR-64 |
Burning position: |
S180 (universal) |
Lamp life: |
300 h |
Dimensions (LxD): |
152,4x204 mm |
Weight: |
850 g |
PU |
EAN |
Weight |
Dimensions |
1 |
4062172359238 |
1,13 kg |
18cm x 18cm x 20cm |
1 |
4008321905789 |
1,09 kg |
18cm x 18cm x 20,5cm |
6 |
4062172359245 |
7,70 kg |
56cm x 37,5cm x 23cm |
6 |
4008321905796 |
7,35 kg |
56cm x 37cm x 23cm |
|
HMI 2500/SE G38 Osram Discharge Lamp 2500W
Technical Info
Type: HMI DE/SE: SE Watt: 2500W Lifetime/H: 500 Box Quant.: 1 Socket: G38 |
General Electric Theatre Lamp 2800-3000K 230V-500W
- Watt : 500
- Base : GY 9.5
- Lumen : 11.000
- Lamp Life : 400 h
- Temperature : 3.050K
- Volt : 240
| Product features
- Operation at mains voltage: 120 V | 230 V | 240 V
- Color temperature: 3,000 K (with longer lifespan)
- Color temperature: 3,200 K (for professional film and TV work)
Areas of application
- Professional film and TV work
- Theater and concert stages
- Entertainment
Safety advice
To prevent personal injury or damage to property, halogen lamps may only be operated in suitable luminaires designed with suitable mechanisms (protective shields, grids, etc.) to ensure that in the event of a lamp bursting no parts/shards can escape and that during operation no ultraviolet radiation can escape. There must also be a warning sign to indicate that the lamps give off high levels of heat. Detailed information is available on request.
Photometrical data |
Color temperature |
3200 K |
Dimensions & weight |
Diameter |
26.0 mm |
Length |
110.0 mm |
Light center length (LCL) |
55.0 mm |
Illuminated field |
13.0*15.0 mm² |
Filament diameter |
15.0 mm |
Additional product data |
Base (standard designation) |
GX9.5 |
Capabilities |
Burning position |
s90 |
Certificates & standards |
EEI – Energy Label |
B |
Country specific categorizations |
ANSI code |
FVA |
LIF |
CP/70 |
Order reference |
64745 |
Electrical data |
Nominal wattage |
1000.00 W |
Nominal voltage |
240 V |
|
Reviews