24 AWG stranded (7×32) TC conductor, polyolefin insulation, individually shielded Beldfoil?
(100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip
simultaneously, overall Beldfoil shield and 24 AWG TC drain wire.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Pairs: 8
Total Number of Conductors: 16
AWG: 24
Stranding: 7×32
Conductor Diameter: .024 in.
Conductor Material: TC – Tinned Copper
INSULATION :
Insulation Material: PO – Polyolefin
Nom. Insulation Wall Thickness: .008 in.
Insulation Diameter: .040 in.
Lay Length: 1.75 in.
Twists/ft.: 6.85
Pair Color Code Chart: Red & Black
INNER SHIELD :
Inner Shield Material Trade Name: Beldfoil?
Inner Shield Type: Tape
Inner Shield Material: Aluminum Foil-Polyester Tape
Inner Shield % Coverage: 100 %
Inner Shield Drain Wire AWG: 24
Inner Shield Drain Wire Stranding: 7×32
Inner Shield Drain Wire Conductor Material: TC – Tinned Copper
INNER JACKET :
Inner Jacket Material: PVC – Polyvinyl Chloride
Inner Jacket Nominal Wall Thickness: .014 in.
Inner Jacket Diameter: .111 in.
OVERALL CABLING : Overall Cabling Color Code Chart:
Number Color
1 Brown
2 Red
3 Orange
4 Yellow
5 Green
6 Blue
7 Purple
8 Gray
OUTER SHIELD :
Outer Shield Material Trade Name: Beldfoil?
Outer Shield Type: Tape
Outer Shield Material: Aluminum Foil-Polyester Tape
Outer Shield %Coverage: 100 %
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG: 18
Outer Shield Drain Wire Stranding: 7×26
Outer Shield Drain Wire Conductor Material: TC – Tinned Copper
OUTER JACKET :
Outer Jacket Material: PVC – Polyvinyl Chloride
Outer Jacket Nominal Wall Thickness: .033 in.
Outer Jacket Ripcord: Yes
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .452 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -35°C To +75°C
Bulk Cable Weight: 103.5 lbs/1000 ft.
Max. Recommended Pulling Tension: 152 lbs.
Min. Bend Radius (Install): 4.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
PLENUM/NON-PLENUM :
Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS :
Nom. Inductance: .18 ?H/ft
Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft
Nominal Velocity of Propagation: 66 %
Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft
Max. Operating Voltage – UL: 300 V RMS
Max. Recommended Current: 1.05 Amps per conductor @ 25°C
NOTE:Price per meter