Content | Conductor drains Ø mm: OFC 28 x 0,10
Conductor insulation: PE red+blue
Conductor insulation Ø in mm: 1,5
Filler material: paper + cotton yarn
1st shield: OFC twisted 83 x 0,12
2nd shield: -
Outer isolation: PVC black, blue, red, yellow, green
Outer isolation Ø in mm: 6
Conductor resistance: 80 Ohm/Km
Shield resistance: 25 Ohm/Km
Capacity Inner conductor: 45 pF/m
Cap. Inner conduct. Shield/Inner conduct.: 112 pF/m
Working temperature: -20~60 °C (min. / max.)
Working Voltage overflash: 30V
Nom Impedance: 110 Ohm | 7138 High Quality Microphone Cable Analog and Digital AES/EBU
Meeting the 110 ohm AES/EBU standard, this high quality balanced microphone cable is suitable for both analog and digital transmission. It features a pair of finely stranded oxygen-free copper conductors with a cross-sectional area of 0.22 mm² and a dual spiral shield of bare copper on a semiconductor layer. A thick, yet flexible PVC jacket and the PVC filler provide strength and excellent resistance to abrasion and impact.
Overall diameter
6.2 +/- 0.2 mm
Center conductor cross section
0.22 mm²
Center conductor material
Copper OFC
Center conductor construction
28 x 0.10 mm
Number of internal conductors
2
Shield material
Double Copper Spiral Shielding with 2x 88 x 0,1mm and semiconductor
Line resistance
50 Ohm(s)
| MCD-224
Dual line cable, 100m. on spool
Technical Info
• Conductor drains Ø mm: OFC 20x0,12
• Conductor insulation: PE
• Conductor insulation Ø in mm: 1,4
• Filler material: -
• 1st shield: OFC braided
• 2nd shield: -
• Outer isolation: PVC black
• Outer isolation Ø in mm: 2x4
Conductor resistance: 80 Ohm/Km
Shield resistance: 25 Ohm/Km
Capacity Inner conductor: 65 pF/m
Capacity Inner cond Shield / Inner cond: 82 pF/m
Working temperature min / max: -20~60 °C
Working Voltage overflash: 30V
Nom Impedance: 100 Ohm |
Conductor drains Ø mm: OFC 28 x 0,10 Conductor insulation: PE red+blue Conductor insulation Ø in mm: 1,5 Filler material: paper + cotton yarn 1st shield: OFC twisted 83 x 0,12 2nd shield: - Outer isolation: PVC black, blue, red, yellow, green Outer isolation Ø in mm: 6
Conductor resistance: 80 Ohm/Km Shield resistance: 25 Ohm/Km Capacity Inner conductor: 45 pF/m Cap. Inner conduct. Shield/Inner conduct.: 112 pF/m Working temperature: -20~60 °C (min. / max.) Working Voltage overflash: 30V Nom Impedance: 110 Ohm | The 7119 is a professional microphone cable for balanced, low-impedance applications. It sports a pair of high strand count oxygen-free copper conductors with a cross section area of 0.30 mm² that are twisted for excellent common mode rejection. The conductors are insulated with 1.5 mm PE for very low capacitance. A braided shield of tinned copper provides efficient EMI and RFI protection for clear, quiet signal transfer. The tough, hard wearing PVC jacket is highly flexible and abrasion resistant in any live, studio and home recording environment.
Overall diameter
6,5 mm +/- 0,2 mm
Center conductor cross section
0.3 mm²
Center conductor material
Copper bare, OFC
Center conductor construction
38 x 0,10 mm mm
Number of internal conductors
2
Shield material
Copper tin-plated
Line resistance
53 Ohm(s)
| The runner marathon doesn't have it easy. He must run and run. In sporting arenas our cables also must put long distances behind themselves. But they neither lie around, nor do they run. The diameter of 2 x 0.50 mm² makes this cable ideal for theatres, public buildings, sporting arenas, etc. Because of the 100 % shielding and a thick outer jacket the SIGMA is also recommended for installation in discos and night clubs. Neither aggressive nicotine nor strong variations in temperature can affect this cable. Stage technicans swear by it and the touring sound agencies prefer the SIGMA because of its endurance and "memory“, making manual winding easy. Halogen-free version available upon request.
Advantages
- Optimum transmission quality even for long lengths due to the large wire diameter of 2 x 0.50 mm²
- 100 % Copper spiral shielding and additional metalic fleece
- Durability due to a thick PVC-jacket with a diameter of 0.264 inch
- Easy to wind and good tensile strength
Application
- Broadcast and transmission vehicle technology, building installation
- Professional studio technology
- Extreme stage application
- Installation in discos, cafés, sporting events
Technical Data
- Construction (2LI2Y0,50mm²)(ST)DY
- Jacket, diameter PVC 6,7 mm
- AWG 21
- ANo. of inner conductors 2 x 0,50 mm²
- Copper strand per conductor 28 x 0,15 mm
- Conductor insulation PE 1,65 mm
- Shielding copper spiral sleeve tin-plated + metalic fleece
- Shielding factor 100 %
- Temperature range min. -30 °C
- Temperature range max. 70 °C
- Fire load per m 0,23 kWh
- Weight per 1 m 53 g
- Packaging 100/500 m roll
Electrical Data
- Capac. cond./cond. per 1 m 80 pF
- Cond. resistance per 1 km 37 Ohm
- Capac. cond./shield. per 1 m 145 pF
- Shield. resistance per 1 km 21 Ohm
- Insulation resist. per 1 km > 1 GOhm
|