Content |
*8 BGM Input/6BUS Output Matrix *Inbuilt Monitor Loundspeaker *Clear LED/LCD Status Indicators *Priority Broadcast Options(EM→Fire→Timer→Paging→RM1-4→LOCAL→BGM) *Remote Operation Control Via RS 232C *Inbuilt EM Microphone *Power Source: 100~120VAC or 220~240VAC; 50/60Hz, DC 24V(Supplied AC mains trancsformer depends on country requirements) *Power Consumption: 22W *Weight: 3.8kg/9.3Ib *Dimensions(W×H×D): 482×132×380mm/19×5.2×15in
|
This model should be used with concerning equipment (emergency switcher-our model ES-9116, matrix-our model PX-9116, emergency panel-our model EP-9216). Specification Brand | InterM | Model | RG-9116 | Features | Speaker line switching; broadcasting status indicators (LED). | Power supply | 24V DC | Dimensions | 482 x 44 x 280 mm | Weight | 3,8 kg | Warranty | 12 months |
|
- PRIORITY CONTROL It controls the priority of emergency, timer, remote1, remote2, main(normal). - AUTO FIRE SENSOR The fire alarm will be given automatically to the designated areas by detecting fire sensor input. - SPEAKER SWITCHING ON EMERGENCY OR NORMAL(MAIN) You can control the speaker relay on emergency or normal(main) mode by using the speaker switch on front panel. - DISPLAY STATUS You can easily check the priority status. - 2 AND 3 WIRE SPEAKER LINE SYSTEM You can control the speaker line on the 2 wire system or 3 wire system. - EXTENSION FUNCTION You can easily expand by connecting additional ECS-616.
ECS-616 | Priority Control | Emergency >Timer > Remote1 > Remote2 > Main | Link in/ out Interface | RS-422(19200bps,Data 8bits,Stop 1bit, Non Parity bit, Start1bit) | Link in/ out interface Distance | 1.2 km | Operation Temperature | -10 °C ~+ 40 °C | Power Source | 24V DC | Power Consumption | 900mA | Weight | 4.8Kg/10.6Ib | Dimensions( W x H x D) | 482(W)x 88(H) x 380(D) mm / 19(W)x 3.5(H)x 15(D)in | ※ Specifications and design subject to change without notice. |
| RM-200M - Five/ten zone console for VM-2120/2240 amplfiers
The RM-200M Remote Microphone that allows announcements to be made to any speaker zone and emergency announcements to all zones on a system with the VM-2120/2240 system management amplifiers.
These announcements can be made live or pre-recorded announcements
can be activated. The remote microphone is connected by cable to the
RM-210 Remote Microphone Extension unit.
SPECIFICATIONS:
Power Requirement |
24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.) |
Distortion |
Less than 1% |
Frequency Response |
100 - 10,000 Hz |
Distortion |
Less than 1% |
Signal-to-Noise Ratio |
More than 60 dB |
Audio Output |
0 dB*1, 600 O, balanced |
Microphone |
Unidirectional electret condenser microphone, gooseneck type. |
Speaker Zone Control |
Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast |
Emergency Broadcast |
Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch |
Voice Announcement Board Control |
Activation of 5 messages*2 |
Number of Connectable Units |
Up to 4 |
Communication System |
RS-485 |
Volume Control |
Microphone volume control |
Connection Cable and Connector Category |
5 STP cable, RJ45 connector |
Communication Distance |
800 m maximum in total |
Finish |
ABS resin |
Dimensions |
190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded) |
|
*1 0 dB = 1 V
*2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier. |
|
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source
|
24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)
|
Current Consumption
|
120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)
|
Frequency Response
|
200 Hz - 15 kHz
|
Distortion
|
1 % or less
|
S/N Ratio
|
55 dB or more
|
Microphone
|
Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
|
Volume Control
|
Microphone volume control, Buzzer volume control
|
Connection Cable
|
Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
|
Maximum Cable Distance
|
Total 800 m (874.89 yd)
|
No. of Connectable RM-320F
|
Max. 3 units
|
Operation
|
Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch
|
Indicator
|
Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator
|
Operating Temperature
|
-5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
|
Operating Humidity
|
5 % to 95 %RH (no condensation)
|
Finish
|
ABS resin, blueish gray (PANTONE 538 or its equivalent)
|
Dimensions
|
200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)
|
Weight
|
1.1 kg (2.43 lb) (with wall mounting bracket unit)
|
Accessory
|
Wall mounting bracket unit…1, Wall mounting screw…2
|
|
| - AUTOMATIC CHARGING Tapered charging circuitry charges your backup batteries without risk of overcharging. - EASY BATTERY MONITORING Integrated digital volt meter and digital ampere meter allow you to monitor the status of your batteries. | | | | | PB-607 | Battery Requirement | 24V DC | Starting Current | 3A Max. | Charge Complete Voltage | 27.3V ±10% | Operation Temperature | -10℃~+40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 130W | Weight(SET) | 7Kg/15.4Ib | Dimension(SET) | 482(W) x 88(H) x 280(D)mm/19(W) x 3.5(H) x 11(D)in | | | |
|