Large diaphragm cardioid microphone Pressure gradient transducer with with one-diaphragm capsule Transformerless circuitry Extremely low noise: 7 dB-A Includes swivel mount Straightforward handling for homerecording and professional studios High-quality professional equipment for limited budgets Acoustical operating principle Pressure gradient transducer Directional pattern Cardioid Frequency range 20 Hz … 20 kHz Sensitivity at 1 kHz into […]

 

Read more

Large diaphragm cardioid microphone
Pressure gradient transducer with with one-diaphragm capsule
Transformerless circuitry
Extremely low noise: 7 dB-A
Includes swivel mount
Straightforward handling for homerecording and professional studios

High-quality professional equipment for limited budgets

Acoustical operating principle Pressure gradient transducer
Directional pattern Cardioid
Frequency range 20 Hz … 20 kHz
Sensitivity at 1 kHz into 1 kohm 23 mV/Pa
Rated impedance 50 ohms
Rated load impedance 1 kohms
Equivalent noise level, CCIR1) 17.5 dB
Equivalent noise level, A-weighted1) 7 dB-A
Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 76.5 dB
Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) 87 dB
Maximum SPL for THD 0.5%2) 138 dB
Maximum output voltage 13 dBu
Dynamic range of the microphone amplifier (A-weighted) 131 dB
Supply voltage (P48, IEC 61938) 48 V ± 4 V
Current consumption (P48, IEC 61938) 3 mA
Matching connector XLR3F
Weight approx. 450 g
Diameter 60 mm
Length 132 mm

 

Weight 3.00 kg

Reviews

There are no reviews yet.

Be the first to review “NEUMANN TLM-103 Condenser studio microphone”

Your email address will not be published. Required fields are marked *

Quick Comparison

NEUMANN TLM-103 Condenser studio microphone removeNEUMANN M-147 TUBE Condenser Cardiodic Microphone removeRODE NTK TUBE CONDENSER STUDIO MICROPHONE removeAKG C414-XLS - Large Diaphragm Condenser Microphone with Five P removeRODE K2 VARIABLE PATTERN CONDENSER VALVE MICROPHONE removeRODE NT-1000 1 STUDIO CONDESER MICROPHONE remove
NameNEUMANN TLM-103 Condenser studio microphone removeNEUMANN M-147 TUBE Condenser Cardiodic Microphone removeRODE NTK TUBE CONDENSER STUDIO MICROPHONE removeAKG C414-XLS - Large Diaphragm Condenser Microphone with Five P removeRODE K2 VARIABLE PATTERN CONDENSER VALVE MICROPHONE removeRODE NT-1000 1 STUDIO CONDESER MICROPHONE remove
Image
SKUH11NE00039H11NE00019H11RD00012C414-XLSH11RD00006H11RD00002
Rating
Price 1,169.00 incl. GR VAT 2,959.00 incl. GR VAT 599.00 incl. GR VAT1,116.00 incl. GR VAT 749.00 incl. GR VAT 332.00 incl. GR VAT
Stock

Available on backorder

Available on backorder

Available on backorder

Available on backorder

Available on backorder

Available on backorder

AvailabilityAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorder
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content
Large diaphragm cardioid microphone
Pressure gradient transducer with with one-diaphragm capsule
Transformerless circuitry
Extremely low noise: 7 dB-A
Includes swivel mount
Straightforward handling for homerecording and professional studios

High-quality professional equipment for limited budgets

Acoustical operating principle Pressure gradient transducer
Directional pattern Cardioid
Frequency range 20 Hz ... 20 kHz
Sensitivity at 1 kHz into 1 kohm 23 mV/Pa
Rated impedance 50 ohms
Rated load impedance 1 kohms
Equivalent noise level, CCIR1) 17.5 dB
Equivalent noise level, A-weighted1) 7 dB-A
Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 76.5 dB
Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) 87 dB
Maximum SPL for THD 0.5%2) 138 dB
Maximum output voltage 13 dBu
Dynamic range of the microphone amplifier (A-weighted) 131 dB
Supply voltage (P48, IEC 61938) 48 V ± 4 V
Current consumption (P48, IEC 61938) 3 mA
Matching connector XLR3F
Weight approx. 450 g
Diameter 60 mm
Length 132 mm

 

Acoustical operating principlePressure gradient transducer
Directional patternCardioid
Frequency range20 Hz ... 20 kHz
Sensitivity at 1 kHz into 1 kohm20 mV/Pa
Rated impedance50 ohms
Rated load impedance1000 ohms
Equivalent SPL CCIR 468-324 dB
Equivalent SPL DIN/IEC 65112 dB-A
S/N ratio CCIR 468-370 dB
S/N ratio DIN/IEC 65182 dB
Maximum SPL114 dB for THD
Maximum output voltage8 dBu
Dyn. range of the mic. amplifier DIN/IEC 651102 dB for THD
Supply voltagePower supply N 149 A
Matching connectorMicrophone: DIN 8F, Power Supply: XLR 3F
Weight460 g
Diameter57 mm
Length142 mm

Rode's new NTK has the quality and warmth demanded from a tube mic.
With the large 1 in. capsule gold-plated membrane and twin triode tubes
(hand graded and selected), Rode is again setting the standard for value.
This is a tube mic designed exclusively for recording professionals who
want what only the best can offer.

Features:
Dynamic range of 47dB
Ultra low noise of only 12dB
Internal capsule shock mounting
Cardioid polar pattern
20Hz - 20kHz frequency response
Includes a power supply, 30 ft. cable, and stand adapter

Technical Description:
Capsule: Externally polarised 1 in. pressure-gradient condenser
Active Electronics: Unity-gain closed-loop impedance converter;
vacuum-tube input with bipolar buffering
Pickup Pattern: Cardioid
Frequency Response: 20Hz - 20kHz (+/-6dB)
Output Impedance: 200 ohms (100 ohms per leg)
Sensitivity: -38dB re 1V/Pa (12mV @ 94dB SPL) +/-1dB
Equivalent Noise: 12dB SPL (A-weighted per IEC268-15) +/-2dB
Maximum Output: > +29dBu (@ 1kHz, 5% THD into 1k (load)
Dynamic Range: > 147dB (A-weighted, per IEC268-15)
Maximum SPL: > 158dB SPL (@ 1kHz, 5% THD into 1k (load)
Signal/Noise Ratio: > 82dB (A-weighted, per IEC268-15)
External power supply: 100-120V/200-240V AC (user selectable)
50Hz/60Hz, 25VA maximum
Packed Weight: 4.53 kg (Mic only 760 gm)

Accessories included:
Power Supply
30 ft (10 m) Multicore Cable
M2 Standmount plus 3/8-5/8 in. Thread Adapter
Optional Extras: SM2 Shockmount

The C 414 B/XLS has been carefully designed to maintain the legendary sonic character of the C 414 family while integrating new features and performance enhancements made possible by new technology. The C 414B/XLS is designed to deliver accurate pickup of all acoustic instruments and voices. The microphone's 5 pickup patterns are easily selectable via an electronic switch with LED indication and offer the selection of omnidirectional, cardioid, wide cardioid, hypercardioid and figure-eight patterns. The pickup pattern selector switch utilizes a dual-color LED indicator that provides visual indication of the pattern selected and also changes from green to red to indicate if the microphone's output electronics are being overloaded. The pattern selector can also be used to "lock" the microphone's switch settings by pressing and holding it for 3 seconds. On the rear of the microphone, an electronic switch allows the selection of -6 dB, -12 dB and -18 dB pre-attenuation levels which are accomplished by changing the polarization voltage to the capsule. The C 414 B/XLS has switchable bass cut filters of 12 dB-per-octave at 40 Hz and 80 Hz, and a 6-dB-per-octave filter at 160 Hz for control of proximity effect. On-axis sensitivity for all patterns is 23 mV/Pa and its self-noise is an extremely low 6 dB-A. The C 414 B/XLS has a transformerless output and all-metal chassis, making it immune to electrical interference and RF from digital equipment, video monitors and wireless systems. It comes complete in an all-metal road case with the AKG H-85 shock mount, a PF80 external two-stage pop filter, a W414X external windscreen and an individually-measured chart showing the response curve of the microphone. It is also available in factory-matched stereo pairs packaged with a H50 stereo bar instead of the external pop filter. The C 414B/XLS is built in Vienna, Austria and comes with a three-year limited parts and labor warranty. Features High sensitivity and extremely low self noise Five switchable polar patterns for placement and application flexibility Two-color LEDs provide quick visual indication of selected polar pattern and output overload Elastic capsule suspension greatly minimizes structurally-transmitted noise from chassis vibration H 85 professional shock mount/stand adapter, PF 80 external pop filter and W 414 X external windscreen High sound pressure level capability and wide dynamic range Completely immune to electrostatic and electro-magnetic interference from digital gear, computer monitors, etc. thanks to solid metal housing and transformerless output stage Three switchable bass cut filters and three pre-attenuation pads with LEDs for quick visual indication All switchable components operate in low impedance circuits for ultra-high relability even in extremely humid conditions Optional R 414 remote control unit (available by the end of 2004) offers full control of all switchable parameters via standard microphone cable and 3-pin XLR-type connectors Specifications Type: 1" large diaphragm pressure gradient microphone Polar Patterns: Omnidirectional, wide cardioid, cardioid, hypercardioid, figure eight Frequency Range: 20 to 20,000 Hz Sensitivity: 23 mV/Pa (-33 dBV) +/-0.5 dB Max. SPL: 140/146/152/158 dB SPL (at 0/-6/-12/-18 dB) Preattenuation Pad: -6, -12,-18 dB, switchable Bass Cut Filter Scope: 12 dB/octave at 40 Hz and 80 Hz; 6 dB/octave at 160 Hz Power Requirements: 48 V phantom power to DIN/IEC Connector: 3-pin XLR Dimensions: 2" x 1.5" x 6.3“ Net Weight: 10.6 oz Shipping Weight: 5 lbs (2.27 kg)

K2 - ?It cant be done?? Precision Variable Pattern Dual 1? Condenser Valve Microphone.
 
The R?DE K2 is the result of designing and building 1000?s of valve microphones. The
K2?s HF-1 capsule is the pinnacle of transducer technology. The sound quality combines
modern high-end specifications with the character and subtleties of the legendary 50?s mics.
Infinitely variable control of the K2?s polar patterns provides the freedom and flexibility to
excel in any recording situation. The K2 is another example of R?DE?s commitment to
building quality studio microphones to meet the exacting standards demanded by today?s
professionals.At the 2004 Frankfurt Music Messa, 56 of the most prestgious music industry
magazines voted the K2 the ?Best Studio Microphone of 2004?.

SPECIFICATIONS:
Features:
? New large capsule with gold sputtered diaphragm. ? Ultra low noise.
? Wide dynamic range. ? Class ?A? valve circuitry. ? Hand-selected and
graded 6922 twin-triode valve. ? Dedicated Power Supply. ? High strength
welded and heat-treated steel mesh head. ? Durable satin nickel finish.
? Internal capsule shock mounting. ? High level of RF rejection. ? Supplied
complete with SM2 Shock Mount and RC2 Custom Carry Case.
? Continuously variable polar patterns. From omni, through cardiod to
figure 8, controlled at the power supply.
Operation power:
The K2 is designed to operate from a dedicated power supply (110 - 120 V/220 - 240 V, 50/60 Hz)
Acoustic principle: Externally polarized 25 mm(1?) condenser.
Directional pattern:
Continuously variable multi pattern -Omni, through Cardioid to figure 8.
Frequency range:  20 Hz - 20 kHz
Output impedance:
Valve impedence converter with bipolar output buffer.
Signal noise ratio din iec 651:
 > 81 dB (1kHz relative to 1 Pa; per IEC651,IEC268-15).
Equvalent noise:  10 dBA SPL (per IEC651, IEC268-15).
Maximum spl: 162 dB (@ 1% THD into 1k).
Sensitivity:
 -36 dB re 1 Volt/Pascal (16 mV @ 94 dB SPL) +/- 2 dB.
Power supply voltage:
Dedicated Power Supply(110 - 120 V/220 - 240 V, 50/60 Hz).
Weight:  815 gms
Dimensions width:  208.5 mm
Dimensions depth:  55 mm
Dimensions height:  55 mm
Maximum output voltage:  > +30 dBu (@ 1% THD into 1 k).

NT1000 - ?Pure Performance? Ultra Versatile 1? Studio Condenser Microphone.

With its ultra low 6 dBA self-noise and transformer less SMT circuitry, the
R?DE NT1000 exhibits exceptional performance when recording both vocals
and instruments in the studio.
Voiced for ?application versatility?, the NT1000 has been hailed by many as the
ultimate drum over-head and grand piano mic selection. The NT1000 is also
equally at home as a first call vocal mic. With its Australian made 1? HF-2 capsule
incorporating internal shock mounting, the NT1000 boasts a 134 dB dynamic range,
and 140 dBA SPL capabilities and a 20 Hz ? 20 kHz frequency response.
Built of a heavy-duty cast metal satin nickel body, the NT1000 incorporates a
high-strength, heat-treated mesh head, and comes supplied in a zip pouch with a
stand mount.

SPECIFICATIONS:
Acoustic principle:
Externally polarised 1? (25mm) pressure-gradient condenser
Directional pattern: Cardioid
Frequency range: 20Hz - 20kHz
Output impedance: 100?
Signal noise ratio din iec 651:
> 88dB (A-weighted, per IEC268-15)
Equvalent noise:
6dB SPL (A-weighted per IEC268-15) +/-1dB
Maximum spl:
> 140dB SPL (@ 1kHz, 1% THD into 1k( load)
Sensitivity:
-36dB re 1V/Pa (16mV @ 94dB SPL) +/-1dB
Dynamic range din iec 651: > 134dB (A-weighted, per IEC268-15)
Power supply voltage: P48 (35V - 53V)
Current consumption: 6mA
Weight without battery: 682 gm
Weight with battery:  882 gm

Weight3.00 kg0.46 kg2.00 kg2.27 kg2.00 kg1.50 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 3.00 kg
Weight 0.46 kg
Weight 2.00 kg
Weight 2.27 kg
Weight 2.00 kg
Weight 1.50 kg