Content |
Classic proportions combined with attractive styling and fresh ideas – the TLM 107 perfectly embodies the Neumann philosophy: Innovation based on tradition. Far from evoking vintage or retro nostalgia, the standard-setting TLM 107 represents an impressive, modern studio microphone. Its extensive performance spectrum and high-precision reproduction, very close to the original, make the TLM 107 universally applicable, opening up the widest freedom in mixing and post-production. |
Rode's new NTK has the quality and warmth demanded from a tube mic.
With the large 1 in. capsule gold-plated membrane and twin triode tubes
(hand graded and selected), Rode is again setting the standard for value.
This is a tube mic designed exclusively for recording professionals who
want what only the best can offer.
Features:
Dynamic range of 47dB
Ultra low noise of only 12dB
Internal capsule shock mounting
Cardioid polar pattern
20Hz - 20kHz frequency response
Includes a power supply, 30 ft. cable, and stand adapter
Technical Description:
Capsule: Externally polarised 1 in. pressure-gradient condenser
Active Electronics: Unity-gain closed-loop impedance converter;
vacuum-tube input with bipolar buffering
Pickup Pattern: Cardioid
Frequency Response: 20Hz - 20kHz (+/-6dB)
Output Impedance: 200 ohms (100 ohms per leg)
Sensitivity: -38dB re 1V/Pa (12mV @ 94dB SPL) +/-1dB
Equivalent Noise: 12dB SPL (A-weighted per IEC268-15) +/-2dB
Maximum Output: > +29dBu (@ 1kHz, 5% THD into 1k (load)
Dynamic Range: > 147dB (A-weighted, per IEC268-15)
Maximum SPL: > 158dB SPL (@ 1kHz, 5% THD into 1k (load)
Signal/Noise Ratio: > 82dB (A-weighted, per IEC268-15)
External power supply: 100-120V/200-240V AC (user selectable)
50Hz/60Hz, 25VA maximum
Packed Weight: 4.53 kg (Mic only 760 gm)
Accessories included:
Power Supply
30 ft (10 m) Multicore Cable
M2 Standmount plus 3/8-5/8 in. Thread Adapter
Optional Extras: SM2 Shockmount
|
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohms | 18 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 21 dB | Equivalent SPL DIN/IEC 651 | 10 dB-A | S/N ratio CCIR 468-3 | 73 dB | S/N ratio DIN/IEC 651 | 84 dB | Maximum SPL for THD 0.5% | 140 dB | Maximum output voltage | 13 dBu | Dynamic range of the microphone amplifier DIN/IEC 651 | 130 dB | Supply voltage | 48 V ± 4 V | Current consumption | 3 mA | Matching connectors | XLR 3F | Weight | 480 g | Diameter | 49 mm | Length | 175 mm |
|
NT1000 - ?Pure Performance? Ultra Versatile 1? Studio Condenser Microphone.
With its ultra low 6 dBA self-noise and transformer less SMT circuitry, the
R?DE NT1000 exhibits exceptional performance when recording both vocals
and instruments in the studio.
Voiced for ?application versatility?, the NT1000 has been hailed by many as the
ultimate drum over-head and grand piano mic selection. The NT1000 is also
equally at home as a first call vocal mic. With its Australian made 1? HF-2 capsule
incorporating internal shock mounting, the NT1000 boasts a 134 dB dynamic range,
and 140 dBA SPL capabilities and a 20 Hz ? 20 kHz frequency response.
Built of a heavy-duty cast metal satin nickel body, the NT1000 incorporates a
high-strength, heat-treated mesh head, and comes supplied in a zip pouch with a
stand mount.
SPECIFICATIONS:
Acoustic principle:
Externally polarised 1? (25mm) pressure-gradient condenser
Directional pattern: Cardioid
Frequency range: 20Hz - 20kHz
Output impedance: 100?
Signal noise ratio din iec 651:
> 88dB (A-weighted, per IEC268-15)
Equvalent noise:
6dB SPL (A-weighted per IEC268-15) +/-1dB
Maximum spl:
> 140dB SPL (@ 1kHz, 1% THD into 1k( load)
Sensitivity:
-36dB re 1V/Pa (16mV @ 94dB SPL) +/-1dB
Dynamic range din iec 651: > 134dB (A-weighted, per IEC268-15)
Power supply voltage: P48 (35V - 53V)
Current consumption: 6mA
Weight without battery: 682 gm
Weight with battery: 882 gm
|
- Polar pattern: Cardioid
- Switchable -10dB PAD
- Frequency response: 20 - 20,000 Hz
- Max. SPL: 140/150 dB (THD = 0.5%)
- Electrical impedance: 200 Ohm
- Requires phantom power
- Diameter: 53 mm
- Length: 162 mm
- Net weight: 320 g
- Colour: Black
- Incl. shock mount
- Highly affordable AKG large-diaphragm microphone technology
- Cardioid polar pattern for multiplicity of vocal and instrument applications
The earlier model C 3000 has had a large fan club in the project studio and home recording worlds for years. For the new C 3000 B, AKG designed a special 1-inch large-diaphragm transducer that closely approximates the vibration performance of top-class studio microphones, but can be made at much lower cost.
Due to its surface area and special capsule tuning, the C 3000 B large-diaphragm transducer produces an exceptionally pleasing, smooth sound. Unlike in the C 3000, the switchable 10-dB preattenuation pad immediately follows the transducer in the signal path, thus increasing the C 3000 B\'s SPL capability by a true 10 dB. Loud sound sources are therefore no problem.
An acoustically optimized cardioid polar pattern makes the C 3000 B an excellent choice for both recording and live sound applications where high gain before feedback is paramount.
Polar pattern |
cardioid |
Frequency range |
20 to 20,000 Hz |
Sensitivity |
25 mV/Pa (-32 dBV) |
Max. SPL |
140/150 dB (k=0,5%) |
Equivalent noise level (CCIR 468-3) |
25 dB |
Equivalent noise level |
14 dB-A |
Signal/noise ratio (A-weighted) |
80 dB |
Preattenuation pad |
10 dB, switchable |
Bass filter |
6 dB/octave below 500 Hz |
Impedance |
200 ohms |
Recommended load impedance |
>1000 ohms |
Supply voltage |
9 to 52 V phantom power to DIN 45596 |
Current consumption |
|
Connector |
3-pin XLR |
Finish |
silver gray |
Net weight |
320 g / 11.3 oz. |
Shipping weight |
950 g / 2.1 lbs. |
Patent(s) |
Electrostatic transducer (Patent no. AT 395.225, DE 4.103.784, JP 2.815.488) |
|
Large diaphragm cardioid microphone | Pressure gradient transducer with with one-diaphragm capsule | Transformerless circuitry | Extremely low noise: 7 dB-A | Includes swivel mount | Straightforward handling for homerecording and professional studios |
High-quality professional equipment for limited budgets
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 23 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1 kohms | Equivalent noise level, CCIR1) | 17.5 dB | Equivalent noise level, A-weighted1) | 7 dB-A | Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) | 76.5 dB | Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) | 87 dB | Maximum SPL for THD 0.5%2) | 138 dB | Maximum output voltage | 13 dBu | Dynamic range of the microphone amplifier (A-weighted) | 131 dB | Supply voltage (P48, IEC 61938) | 48 V ± 4 V | Current consumption (P48, IEC 61938) | 3 mA | Matching connector | XLR3F | Weight | approx. 450 g | Diameter | 60 mm | Length | 132 mm |
|
|
Reviews
There are no reviews yet.