TOA AT-12UPR Volume Control 12W with priority

65.12 incl. GR VAT

Available on backorder

EAN: N/A
Installments calculation
CompareAdd to wishlist Submit Better Price
Volume Control 12W with priority.

 

Read more

Volume Control 12W with priority.

Weight 0.50 kg

Reviews

There are no reviews yet.

Be the first to review “TOA AT-12UPR Volume Control 12W with priority”

Your email address will not be published. Required fields are marked *

Quick Comparison

TOA AT-12UPR Volume Control 12W with priority removeTOA AT-100UPR Attenuator with Relay 100 W removeINTER-M SM-100 15'' SYSTEM MONITOR removeINTER-M PD-659 POWER DISTRIBUTOR/CONTROL UNIT removeTOA RM-200M Remote Microphone Console removeINTER-M PW-642 WEEKLY PROGR.TIMER 5IN/4OUT remove
NameTOA AT-12UPR Volume Control 12W with priority removeTOA AT-100UPR Attenuator with Relay 100 W removeINTER-M SM-100 15'' SYSTEM MONITOR removeINTER-M PD-659 POWER DISTRIBUTOR/CONTROL UNIT removeTOA RM-200M Remote Microphone Console removeINTER-M PW-642 WEEKLY PROGR.TIMER 5IN/4OUT remove
Image
SKUAT-12UPRAT-100UPRSM-100PD-659RM-200MPW-642
Rating
Price 65.12 incl. GR VAT 145.09 incl. GR VAT 1,132.00 incl. GR VAT 314.00 incl. GR VAT 492.47 incl. GR VAT 335.00 incl. GR VAT
Stock

Available on backorder

Available on backorder

Available on backorder

Available on backorder

Available on backorder

Available on backorder

AvailabilityAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorder
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

Volume Control 12W with priority.

toa-at-100upr Build-in Attenuator with Relay
Toa - 100V installation


Build-in Attenuator with Relay 100 W / 100 V

- 15 LCD MONITOR PANEL AND TOUCH SCREEN BUILT-IN FOR CONVENIENCE OF USERS

- EMERGENCY MIC FRONT BUILT-IN FOR EMERGENCY BROADCASTING.

- SPEAKER VOLUME FOR MONITORING INPUT SOURCE AND OUTPUT ZONE.

- ARRANGE THE BUTTON FOR MOVING THE SCREEN BY THE FRONT UI FUNCTION.

SM – 100

Power Source

DC 12V , 3.5 A

Power Consumption

42W

Weight

16.5Kg/14.3Ib

Dimensions( W x H x D)

482x 310.5x 60 mm / 19x12.4x 2.4in

※ Specifications and design subject to change without notice.

- SYSTEM POWER CONTROL

You can control the power of your system by using this model.

- AC AND DC POWER SUPPLY

You can distribute AC and DC power through the AC outlet and DC terminals on the rear panel.

- USE OF EMERGENCY POWER SUPPLY

For emergency equipment power supply, an extra DC terminal is provided.

- REMOTE CONTROL

You can control the system power by remote control function even though the power switch on front is off.

- AC AND DC VOLT METER

This model uses digital volt meter displays of AC and DC.

- OPERATING MODE DISPLAY

You can easily check the operating mode by LEDs, AC or DC operating and emergency power.

PD-659

AC Outlet

Switched 2000W ⅹ3

Unswitched 700W ⅹ1

Remote Control

1

DC Power Output

DC 24V 5A

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied ACmains transformer depends on country requirements)

Power Consumption

190W

Weight(SET)

6.2Kg/13.6Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

※ Specifications and design subject to change without notice.

RM-200M - Five/ten zone console for VM-2120/2240 amplfiers The RM-200M Remote Microphone that allows announcements to be made to any speaker zone and emergency announcements to all zones on a system with the VM-2120/2240 system management amplifiers. These announcements can be made live or pre-recorded announcements can be activated. The remote microphone is connected by cable to the RM-210 Remote Microphone Extension unit. SPECIFICATIONS:
Power Requirement 24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.)
Distortion Less than 1%
Frequency Response 100 - 10,000 Hz
Distortion Less than 1%
Signal-to-Noise Ratio More than 60 dB
Audio Output 0 dB*1, 600 O, balanced
Microphone Unidirectional electret condenser microphone, gooseneck type.
Speaker Zone Control Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast
Emergency Broadcast Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch
Voice Announcement Board Control Activation of 5 messages*2
Number of Connectable Units Up to 4
Communication System RS-485
Volume Control Microphone volume control
Connection Cable and Connector Category 5 STP cable, RJ45 connector
Communication Distance 800 m maximum in total
Finish ABS resin
Dimensions 190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded)
*1 0 dB = 1 V *2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier.

- CONSIDERATION OF USERʼS CONVENIENCE

NUMERIC buttons and various function buttons are separated for timer program enter and convenience in use so that the user can easily operate.

- ADOPTION OF VACUUM FLUORESCENT DISPLAY PANEL

Adopting a vacuum fluorescent display of a dot matrix method enables to check operation status of each function at a glimpse.

- PROGRAMMING USING A PC

You can easily execute reservation setting thorough management program by connecting a PC to the RS-232C port.

- VARIOUS MELODY AND SOUND OUTPUT

You can generate various melodies and sounds by linking the flash memory mounted on this unit to our model, PV-632 (MULTI-VOICE FILE).

- AC POWER OUTPUT CONTROL

When PW-642 and other equipment are connected via the AC outlet terminal of PW-642, you can turn ON/OFF the AC outlet button in the front panel and manually control ON/OFF of the AC power connected to other device.

- BACK-UP POWER

You can continue to maintain the time counter for about a week though the inner back-up even though AC power turns off with current time set. There is no need of readjusting time even though AC power is applied.

- MEASURE AGAINST POWER FAILURE

A separate memory is used to prevent data extinguishment due to power failure or other unstable power.

- AUTOMATIC RETURN

In programming data using a key button on the front side of PW-642 without using a PC, no pressing any button is recognized as cancel of program entry to return to normal operation status.

- AC POWER OUTPUT TIME ADJUSTMENT

You can adjust the AC power output time of PW-642 by 1~20sec to prevent time delay from occurring in the interface with the outside power amp.

- KEY LOCK

You can protect reservations and userʼs setting.

PW - 642

Input Channel (Balanced)

5CH

Output Channel (Balanced)

4CH

Output Level

Maximum 1v

AC Power Output 1

Maximum 500W

AC Power Output 2

Maximum 30 w

Data Preservation Time

7 days and more

Melody Time

(15 settings total - 247 seconds)

No.1

2 seconds

No.2

3 Seconds

No.3

3 Seconds

No.4

5 Seconds

No.5

5 Seconds

No.6

7 Seconds

No.7

7 Seconds

No.8

10 Seconds

No.9

10 Seconds

No.10

15 Seconds

No.11

20 Seconds

No.12

30 Seconds

No.13

30 Seconds

No.14

40 Seconds

No15

60 Seconds

Operation Temperature

-10°C ~+ 40°C

Power Source

100- 120 VAC or 220 -240VAC; 50/60 Hz

(Supplied AC mains transformer depends on country requirements)

Power Consumption

10W

Weight(SET)

5.7Kg/12.6Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

※ Specifications and design subject to change without notice.

Weight0.50 kg1.00 kg6.50 kg6.20 kg3.00 kg5.70 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.50 kg
Weight 1.00 kg
Weight 6.50 kg
Weight 6.20 kg
Weight 3.00 kg
Weight 5.70 kg