Content |
Battery for BP-900 Charger suitable for the TS-800 and 900 series of Infrared Wirless Conference Systems
Nominal Voltage | 7.4 V DC | Nominal Capacity | 1700mAh | Dimensions | 71.6(W) x 20.4(H) x 37.6(D)mm | Weight | 95g | Accessory | Terminal protection cover (pre-installed ath the factory) |
|
- System Features and Outline
- Operations such as giving speech permission can be done from the operation PC. *Custom design.
- The number of conference units can be set for any of one, two or four persons allowed to talk at a time.
- All speeches during the conference can be recorded clearly.
- Sub audio(Japanese interpretation) is not recorded.
- Threefold choice vote function enables the voting just at the press of a Vote key on each unit. The result can be instantly totalized on the Central unit.
- Speeches can be addressed to audience via sound amplification. * The sub audio output is not amplified
SPECIFICATION:
Power Source | 100-240 V AC, 50/60Hz (supplied from AC adapter (accessory)) | Power Consumption | 72W | Input | MIC: -60 dB*, 600O,unbalanced, phone jackAUX: -20 dB*, 10 kO,unbalanced, phone jack | Output | REC: -20 dB*, 10 kΩ, unbalanced, phone jack, RCA pin jack HEADPHONE: Mini jack | Number of Connectable Chairman/Delegate Units | 64 units | Number of Connectable Infrared Transmitter/Receiver Units | 4 units (up to 16 units by using four Distributors) | Infrared Transmitter/Receiver I/O Terminal | 4 BNC jacks | External Control Terminal | D-sub connector (9 P, male) | LED Indicator | Audio signal receiving indicators 1-4 CH,Data signal receiving indicator, External control priority indicator, External control communication indicator, Power indicator, Battery indicator (flashes when a Chairman/Delegate unit's battery nears complete discharge) | Function Switch | Simultaneous speaker No. setting switch: 1/2/4 Mic-off setting switch: TIME OUT ON/OFF
Speech priority selector switch: A/B/C (A: First-in-first-out priority, B: Last-in-first-out priority, C: Fixed for the first unit, and last-in-first-out for the subsequent units) | Operating Temperature | 0º to+40º | Finish | Panel: Surface-treated steel plate, gray metallic, paint, semi-gloss | Weight | 2.7kg | Accessory | AC adapter (Cord length: 1.8 m DC cord, and 2 m detachable AC cord)…1 | Option | Rack mounting bracket: MB-TS900 | | *0dB=1V |
| Infrared radiator for use with TS-800. It comes with wall mount and stand in microphone crane. Coverage area within 7 meters in sight. Power supply via the central unit. Maximum number in each system 16 pcs. |
Power (w/o IEC power cord) for up to 40 microphone units. |
- Choice of microphones for every kind of system and room acoustics.
- Display and multifunction soft keys for ease of use.
- Up to 63 language channels independently selectable for two users.
- 1, 3, 5-way voting/polling function.
- Dip-switch selectable president and delegate operating modes.
The CS 5 VU provides two operating modes, reducing the number of different components needed for a conference system.
In a small discussion system with CS 5 DU microphone stations, the chairperson would typically use a CS 5 VU. In President mode, it provides a priority function and allows the user to start votes or polls. The display will then indicate the time left for voting and the results.
In a larger conference system, the CS 5 VU can be used both by delegates and by the president. In delegate mode, it provides all voting and language selection functions independently for two delegates. A bank of dip switches allows the CS 5 VU to be set to President mode with priority and 1, 3, or 5-way voting/polling functions. In computer-controlled conference systems, chip-card identification is available as an option.
Gooseneck, capsule and connecting cable are not included.
The unit shall act as chairman unit or normal delegate unit, selectable by a dipswitch on the bottom of the housing. It shall have a built-in microphone and loudspeaker, which allow the forwarding of the voice of the speaker towards the other units of the system. The chairman shall always be able to start 1,3 and 5 step voting from the unit and monitor the results on the unitʼs display. Priority calls shall also be possible from his unit.
The CS 5 VU is suitable for taking over maximum 63 interpreted languages and the room voice as well, which may be listened to through the headset that is connected to the device. A chip card reader is also included in the unit, with the aid of which it is possible to identify the user of the device in the case of a computer controlled conference.
The backlit graphic LC display facilitates using the device and displays its current status and the result of the vote. The unit shall operate for 2 persons simultaneously, with independent adjustable languages for each of the 2 x 3,5mm stereo jack headphone sockets.
|
Infrared radiators providing wireless transmission of up to seven language channels for persons (e.g., observers) listing to a conference without asking for the floor.
The infrared radiators shall connected to the CS 5 BU through 2 BNC connectors and 50 Ohm coaxial cabling and serial concatenation. It shall transmit a PPM system modulated time-multiplex outputs of the central unit shall drive an arbitrary number of radiators. The CS 5 IRT1 shall have a radiation angle of +/- 22° and a working distance of 300 meters (with 50% down). The CS 5 IRT2 shall have a radiation angle of +/- 22° and a working distance of 500 meters (with 50% down).
As accessories of the infrared radiators the holding frame needed for mounting it to the side wall or the ceiling shall be included. The transmitter shall have a built in switchable power supply with IEC connector.
|