Content | A dedicated microphone for the VX-2000 system that fulfills the requirements of British and European standards:BS5839 part 8, EN60849 and IEC60849. The RM-200XF is designed to be exclusively used for emergency broadcast, however it can be used for general purpose broadcast applications as well.
Specification |
|
Power Requirement |
24V DC (Operating range: 16 - 40V DC) |
Current Consumption |
Under 200mA (RM-200XF), 850mA (with 10 RM-210s connected) |
Audio Output |
0db*, 600, balanced |
Hand-Held Microphone |
Dynamic microphone, Function switch (default: Press-talk), Microphone element fault detection |
Distortion |
Under 1% |
Frequency Response |
100 - 15,000Hz |
Signal-to-Noise Ratio |
Over 55dB |
Internal Speaker |
200mW |
Volume Control |
Microphone volume control, Monitor speaker volume control |
Number of Function Keys |
5 (including Hand-held micropnone's switch), extendable up to 105 (with 10 RM-210s connected)
Key Extension 10 keys extension per RM-210, EXTENSION connector |
Number of Connectable Units |
4 |
Communication System |
LONWORKS twisted pair free topology transceiver |
Connection Cable and Connector |
Category 5 STP cable, plug-in screw connector |
Communication Distance |
500m (Free topology wiring) |
Finish |
ABS resin, bluish gray (PANTON 538 or its equivalent) |
Dimensions |
200 (W) x 215 (H) x 82.5 (D)mm (excluding the coiled cord) |
Weight |
1.2kg |
Accessory |
Plug-in screw terminal x 1, Wall mounting bracket x 1, Wall mounting screw x 2, Box mounting screw x 2 |
Applicable Box |
YC-301, YC-11A |
|
*0 dB = 1 V |
|
Five attenuation settings (OFF, 0/-6/-12/ -16dB), over an input range from 0.5W to 30W. |
| - AUTOMATIC CHARGING Tapered charging circuitry charges your backup batteries without risk of overcharging. - EASY BATTERY MONITORING Integrated digital volt meter and digital ampere meter allow you to monitor the status of your batteries. | | | | | PB-607 | Battery Requirement | 24V DC | Starting Current | 3A Max. | Charge Complete Voltage | 27.3V ±10% | Operation Temperature | -10℃~+40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 130W | Weight(SET) | 7Kg/15.4Ib | Dimension(SET) | 482(W) x 88(H) x 280(D)mm/19(W) x 3.5(H) x 11(D)in | | | |
|
The ATT-30 from Inter-M Americas is a one-gang wall panel attenuator. The knob has four clearly-labeled steps to make easy adjustments. A screwless terminal block simplifies installation, and the sleek, modern design fits into any environment. The attenuator can handle up to 30W. |
- PRIORITY CONTROL It controls the priority of emergency, timer, remote1, remote2, main(normal). - AUTO FIRE SENSOR The fire alarm will be given automatically to the designated areas by detecting fire sensor input. - SPEAKER SWITCHING ON EMERGENCY OR NORMAL(MAIN) You can control the speaker relay on emergency or normal(main) mode by using the speaker switch on front panel. - DISPLAY STATUS You can easily check the priority status. - 2 AND 3 WIRE SPEAKER LINE SYSTEM You can control the speaker line on the 2 wire system or 3 wire system. - EXTENSION FUNCTION You can easily expand by connecting additional ECS-616.
ECS-616 | Priority Control | Emergency >Timer > Remote1 > Remote2 > Main | Link in/ out Interface | RS-422(19200bps,Data 8bits,Stop 1bit, Non Parity bit, Start1bit) | Link in/ out interface Distance | 1.2 km | Operation Temperature | -10 °C ~+ 40 °C | Power Source | 24V DC | Power Consumption | 900mA | Weight | 4.8Kg/10.6Ib | Dimensions( W x H x D) | 482(W)x 88(H) x 380(D) mm / 19(W)x 3.5(H)x 15(D)in | ※ Specifications and design subject to change without notice. |
|
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source
|
24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)
|
Current Consumption
|
120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)
|
Frequency Response
|
200 Hz - 15 kHz
|
Distortion
|
1 % or less
|
S/N Ratio
|
55 dB or more
|
Microphone
|
Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
|
Volume Control
|
Microphone volume control, Buzzer volume control
|
Connection Cable
|
Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
|
Maximum Cable Distance
|
Total 800 m (874.89 yd)
|
No. of Connectable RM-320F
|
Max. 3 units
|
Operation
|
Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch
|
Indicator
|
Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator
|
Operating Temperature
|
-5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
|
Operating Humidity
|
5 % to 95 %RH (no condensation)
|
Finish
|
ABS resin, blueish gray (PANTONE 538 or its equivalent)
|
Dimensions
|
200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)
|
Weight
|
1.1 kg (2.43 lb) (with wall mounting bracket unit)
|
Accessory
|
Wall mounting bracket unit…1, Wall mounting screw…2
|
|