Content |
The VX-200SZ is an audio signal output module of the VX-2000 system with speaker line impedance detection. This module is to be mounted in the VX-2000SF Surveillance Frame and detects speaker line short circuits, open circuits by comparing impedance readings, and ground fault.
Power Source | Supplied from VX-2000SF | Current Consumption | Under 150 mA | Power Amplifier Link | RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Twisted-pair straight cable (TIA/EIA-568A standard) | External Attenuator Control Output | Plug-in screw connector, relay, no-voltage make contact output,
transfer type, withstand voltage: 30 V DC, 250 V AC,
contact current: Under 7 A (DC), under 7 A (AC)
Applicable cable diameter: AWG 24 - AWG 16 | Speaker Output | Plug-in screw connector
Applicable cable diameter: AWG 24 - AWG 16 | Power Amplifier Input | Plug-in screw connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Applicable cable diameter: AWG 24 - AWG 16 | Fault Detection System | Short circuit, open circuit (impedance detection method), ground fault | Finish | Panel: Surface-treated steel plate | Dimensions | 30.5 (W) × 132.6 (H) × 290.3 (D) mm | Weight | 320 g | Accessory | Plug-in screw terminal……1 | Option | Equaliser card: VX-200SE | Applicable Model | VX-2000SF |
|
| - FAN FOR PA RACK Auto fan operates when the inside temperature of PA RACK goes up. - MANUAL OPERATING When it's manual mode, the fan operates always regardless of temperature. - AUTO OPERATING When it's auto mode, the fan operates at 35°C. | | | | | PF- 602 | Operation Selector Switch | Manual, Auto, Operating temperature | Fan | 2 DC fans | Power Source | 24VDC | Power Consumption | 160mA | Weight | 4Kg/8.8Ib | Dimensions( W x H x D) | 482x 88 x 380 mm / 19 x 3.5 x 15in | ※ Specifications and design subject to change without notice. | | | |
|
- PRIORITY CONTROL It controls the priority of emergency, timer, remote1, remote2, main(normal). - AUTO FIRE SENSOR The fire alarm will be given automatically to the designated areas by detecting fire sensor input. - SPEAKER SWITCHING ON EMERGENCY OR NORMAL(MAIN) You can control the speaker relay on emergency or normal(main) mode by using the speaker switch on front panel. - DISPLAY STATUS You can easily check the priority status. - 2 AND 3 WIRE SPEAKER LINE SYSTEM You can control the speaker line on the 2 wire system or 3 wire system. - EXTENSION FUNCTION You can easily expand by connecting additional ECS-616.
ECS-616 | Priority Control | Emergency >Timer > Remote1 > Remote2 > Main | Link in/ out Interface | RS-422(19200bps,Data 8bits,Stop 1bit, Non Parity bit, Start1bit) | Link in/ out interface Distance | 1.2 km | Operation Temperature | -10 °C ~+ 40 °C | Power Source | 24V DC | Power Consumption | 900mA | Weight | 4.8Kg/10.6Ib | Dimensions( W x H x D) | 482(W)x 88(H) x 380(D) mm / 19(W)x 3.5(H)x 15(D)in | ※ Specifications and design subject to change without notice. |
|
Emergency combination system. Ενσωματώνεται σε σύστημα συναγερμού φωτιάς. Ενσωματωμένο πυκνωτικό μικρόφωνο για Επείγουσα Αναγγελία, Εξωτερική αυτόματη αναγγελία με αρχείο φωνής, Επιλογέας δοκιμής. Ρύθμιση έντασης εξόδου, Βάρος 4,6kg. Διαστάσεις (WxHxD): 482X88X380mm |
The AT series high quality attenuators features 5 attenuation settings ,,OFF'' -18dB,-12db,-6dB,-0dB. An input range from 0.5W to 60W (model dependent), and push-in connectors. Push-in connector allows quick terminal cable connection. Stylishly finished, the AT Series will suit any décor. |
The ATT-30 from Inter-M Americas is a one-gang wall panel attenuator. The knob has four clearly-labeled steps to make easy adjustments. A screwless terminal block simplifies installation, and the sleek, modern design fits into any environment. The attenuator can handle up to 30W. |
Reviews
There are no reviews yet.