Content |
The VX-200SZ is an audio signal output module of the VX-2000 system with speaker line impedance detection. This module is to be mounted in the VX-2000SF Surveillance Frame and detects speaker line short circuits, open circuits by comparing impedance readings, and ground fault.
Power Source | Supplied from VX-2000SF | Current Consumption | Under 150 mA | Power Amplifier Link | RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Twisted-pair straight cable (TIA/EIA-568A standard) | External Attenuator Control Output | Plug-in screw connector, relay, no-voltage make contact output,
transfer type, withstand voltage: 30 V DC, 250 V AC,
contact current: Under 7 A (DC), under 7 A (AC)
Applicable cable diameter: AWG 24 - AWG 16 | Speaker Output | Plug-in screw connector
Applicable cable diameter: AWG 24 - AWG 16 | Power Amplifier Input | Plug-in screw connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Applicable cable diameter: AWG 24 - AWG 16 | Fault Detection System | Short circuit, open circuit (impedance detection method), ground fault | Finish | Panel: Surface-treated steel plate | Dimensions | 30.5 (W) × 132.6 (H) × 290.3 (D) mm | Weight | 320 g | Accessory | Plug-in screw terminal……1 | Option | Equaliser card: VX-200SE | Applicable Model | VX-2000SF |
|
| - IT CAN CHECK SPEAKER WIRE OPEN, SHORT, AND EXCEED VALUE ACCORDING TO SETTING UP IMPEDANCE. - IT AUTOMATICALLY CHECKS SPEAKER WIRES BY PROGRAM TIMER OPERATIONS. THE POSSIBLE SET UP TIMES ARE BETWEEN 20 MINUTES AND 200 MINUTES. - RS-232C TERMINAL IN/OUT CONTROL WITH AMX/CRESTRON INTERFACE. - DC 24V OPERATION. - COMPACT DESIGN 2RU(3.5”). - KEEPS STORED VALUES BY NON VOLATILE MEMORY - ALERT SOUNDS WHEN FAULT IS FOUND - BUZZER ON/OFF FUNCTION. | | | | | SC - 624 | Power source | 24VDC | Power Consumption | 300mA | Weight | 5.2Kg / 11.5lb | Dimensions (WxHxD) | 1482 x 88 x380mm /19 x 3.5 x 15in | | | |
| RM-200M - Five/ten zone console for VM-2120/2240 amplfiers
The RM-200M Remote Microphone that allows announcements to be made to any speaker zone and emergency announcements to all zones on a system with the VM-2120/2240 system management amplifiers.
These announcements can be made live or pre-recorded announcements
can be activated. The remote microphone is connected by cable to the
RM-210 Remote Microphone Extension unit.
SPECIFICATIONS:
Power Requirement |
24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.) |
Distortion |
Less than 1% |
Frequency Response |
100 - 10,000 Hz |
Distortion |
Less than 1% |
Signal-to-Noise Ratio |
More than 60 dB |
Audio Output |
0 dB*1, 600 O, balanced |
Microphone |
Unidirectional electret condenser microphone, gooseneck type. |
Speaker Zone Control |
Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast |
Emergency Broadcast |
Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch |
Voice Announcement Board Control |
Activation of 5 messages*2 |
Number of Connectable Units |
Up to 4 |
Communication System |
RS-485 |
Volume Control |
Microphone volume control |
Connection Cable and Connector Category |
5 STP cable, RJ45 connector |
Communication Distance |
800 m maximum in total |
Finish |
ABS resin |
Dimensions |
190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded) |
|
*1 0 dB = 1 V
*2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier. |
|
| - CONVENIENT INSTALLATION AND CONSTRUCTION WITHOUT NEED OF ID SETTING. - SELECTION OF VARIOUS CHIME BROADCASTINGS FOR MIC BROADCASTING (PRE/POST). - CONVENIENT PRIORITY BROADCASTING. - ADOPTION OF OUTPUT SIGNAL LEVEL DISPLAY. - ADOPTION OF RS-422 COMMUNICATION METHOD TO SUPPORT A LONG DISTANCE. | | | | | | Audio Output | 0dB(Balanced) | Audio Input | Paging & RM MIC & LM MIC | -50dB(Balanced) | BGM(Main & Local) | -10dB(Balanced) | Tone Control (100Hz & 10kHz) | Paging MIC | ± 10dB | Audio Output | ± 12dB | Frequency Response | BGM | ± 3dB | MIC | ± 3dB | S / N | BGM | Better than 75dB | MIC | Batter than 65dB | T.H.D. | BGM | Less than 0.05% | MIC | Less than 0.05% | Priority Control | Paging MIC > DRP > RM1> RM2 > RM3 > RM4 > LM-8000 > Main BGM | Phantom Power | DC 24V | Serial Interface | Communication Speed | 9600bps | Communication Distance | Maximum 300m(UTP CAT%) | Operation Temperature | -10℃ ~ +40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Weight(SET) | 1.5kg / 3.2lb | Dimensions(SET) | 200(W) x 70(H) x 206(D)mm 7.9(W) x 2.8(H) x 8.1(D)in | ※ Specifications and design subject to change without notice. | | | |
|
- PRIORITY CONTROL It controls the priority of emergency, timer, remote1, remote2, main(normal). - AUTO FIRE SENSOR The fire alarm will be given automatically to the designated areas by detecting fire sensor input. - SPEAKER SWITCHING ON EMERGENCY OR NORMAL(MAIN) You can control the speaker relay on emergency or normal(main) mode by using the speaker switch on front panel. - DISPLAY STATUS You can easily check the priority status. - 2 AND 3 WIRE SPEAKER LINE SYSTEM You can control the speaker line on the 2 wire system or 3 wire system. - EXTENSION FUNCTION You can easily expand by connecting additional ECS-616.
ECS-616 | Priority Control | Emergency >Timer > Remote1 > Remote2 > Main | Link in/ out Interface | RS-422(19200bps,Data 8bits,Stop 1bit, Non Parity bit, Start1bit) | Link in/ out interface Distance | 1.2 km | Operation Temperature | -10 °C ~+ 40 °C | Power Source | 24V DC | Power Consumption | 900mA | Weight | 4.8Kg/10.6Ib | Dimensions( W x H x D) | 482(W)x 88(H) x 380(D) mm / 19(W)x 3.5(H)x 15(D)in | ※ Specifications and design subject to change without notice. |
|
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source
|
24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)
|
Current Consumption
|
120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)
|
Frequency Response
|
200 Hz - 15 kHz
|
Distortion
|
1 % or less
|
S/N Ratio
|
55 dB or more
|
Microphone
|
Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
|
Volume Control
|
Microphone volume control, Buzzer volume control
|
Connection Cable
|
Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
|
Maximum Cable Distance
|
Total 800 m (874.89 yd)
|
No. of Connectable RM-320F
|
Max. 3 units
|
Operation
|
Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch
|
Indicator
|
Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator
|
Operating Temperature
|
-5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
|
Operating Humidity
|
5 % to 95 %RH (no condensation)
|
Finish
|
ABS resin, blueish gray (PANTONE 538 or its equivalent)
|
Dimensions
|
200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)
|
Weight
|
1.1 kg (2.43 lb) (with wall mounting bracket unit)
|
Accessory
|
Wall mounting bracket unit…1, Wall mounting screw…2
|
|