Content | Digital Sound 8928 SPL Meter with Built-In Measurement Mic - calibrated from 300Hz to 8kHz (+/-2dB), 4 control zones in 10dB steps (40-130dB), large LCD display, peak-hold, fast/slow display modes, includes 9V battery.
A superbly designed easy to use sound level meter with features normally only found on more expensive instruments. It has an electret condenser microphone giving virtually instant readings updated every 0.5 seconds on an extra large LCD display.
- 4 measuring ranges, 40 to 70dB, 60 to 90dB, 80 to 110dB or 100 to 130dB
- 0.1dB resolution updated every 0.5 seconds
- Auto ranging or manual range selection
- ʽAʼ & ʽCʼ frequency weighting
- Fast or slow response filters
- 42mm LCD display with quasi-analogue bargraph and function Indicators
- Bargraph in 1dB steps updated every 40ms
- Max hold function to display the highest recorded value
- Min/max memory since power on or last reset
- Low battery indicator
- Auto power off
- Analogue output AC: 0.707 Vrms (at full scale)
- Supplied with battery
|
Digilyzer? DL1
Digital audio analyzer / audio meter with integrated speaker, audio lens and a
comprehensive event logger. Digital audio becomes simple by using the Digilyzer DL1.
The digital audio meter Digilyzer DL1 provides a comprehensive set of analysis
functions for digital, audio and video related audio signals.
It handles virtually all digital audio formats including ADAT and sampling frequencies
up to 96 kHz. The simple and intuitive operation allows the user to monitor, analyze
and troubleshoot any digital signals.
Debugging of digital audio signals becames easy with the assistance of the Digilyzer:
Features like the integrity check, the integrated speaker with audio lens function, the
logging functions, the ?over all? view of all important parameters and many more functions
to allow you to understand whats going on and finding faults easier than ever.
The Digilyzer is a handheld, battery powered device with optional mains power supply and
optional USB interface called MiniLINK.
MiniLINK, the USB interface for the Digilyzer allows documentation and data acquisition of
all DL1 functions in conjunction with the easy to use MiniLINK PC application. MiniLINK
supports online data logging up to several days. Read more about MiniLINK.
Product-details
? AES3, S/PDIF, TOS-Link
? ADAT Interface
? Sampling Frequency 32-96 kHz
? Digital Audio Analysis
? Carrier Status Analysis
? Carrier Signal Measurement
? Dual Domain Monitor Speaker
? Comprehensive Event Logger
|
Model Number |
JZK-601 |
Memory groups |
32*2 groups |
Product Dimensions |
14.3* 9.3* 3.8 CM |
Business type |
Manufacturer |
Storage temperature |
-20-50°C |
Storage Humidity |
15%-90%RH |
Operating temperature |
5-40°C |
Operating Humidity |
40%-85%RH |
Display |
LCD crystal digital display |
Measuring method |
Infrared radiation temperature measurement |
Measurement range |
32~42.5℃ fro human body, 0-100℃ for objects |
Resolution |
0.1 degrees Celsius (0.1 degrees Fahrenheit) |
Accuracy |
0-39.9kpa(0-299 mmhg) |
Voltage |
3 V |
Power consumption |
|
|
The MiniSPL is the perfect accessory to the Acoustilyzer & Minilyzer for
acoustical measurements.
The MiniSPL is a battery powered measurement microphone. Together
with the Acoustilyzer or Minilyzer, it forms an acoustical analyzer and integrating
sound level meter. Additionally it may be operated as a stand-alone microphone
e.g. connected to a balanced audio-line, a microphone-input or a sound-card.
Product-details
? Battery powered
? Factory-set sensitivity
? No phantom power required
? 1/2" microphone, class 2 acc. IEC 61672
? Omni-directional
? Supplied with mic clamp, wind protection
? Typical frequency response included
MiniSPL together with Acoustilyzer:
? SPL Meter / RTA
? Reverberation Time RT60
? Delay Time
? FFT Analyzer
? Speech Intelligibility STI-PA
MiniSPL together with Minilyzer:
? Measurements: SPL, min./max., Leq
? 1/3rd octave spectrum analyzer |
ACOUSTILYZER
The Acoustilyzer AL1 functionality complements and expands the ML1
Minilyzer with a new and comprehensive set of acoustical measurement
functions.
The optimized combination of electrical and acoustical features creates
the perfect all in one tool for sound/systems contractors, installers and
multi-media specialists. The Acoustilyzer AL1 is available as a palm-sized
portable acoustical analyzer or as firmware for Minilyzer owners with optional
available STI-PA measurement functionality.
Required Accessories:
The AL1 requires a measurement microphone for acquiring acoustical signals.
NTI offers the following microphones:
- MiniSPL, class 2 acc. IEC 61672
- M2010, class 1 frequency response (ext. phantom power supply required)
Product Details
Sound Pressure Level: Leq, short-time Leq , LE, Lmin, Lmax,
Real Time Analyzer: 1/1 or 1/3 octave band resolution SPL/LEQ display per
band, max - min display
Zoom FFT: Actual level and Leq, full band up to 0.7Hz resolution
Reverberation Time: RT60 with 1/1 octave band resolution, confidence indicator,
according to ISO3382
Delay Time: Propagation delay between electrical and acoustical signal (built in mic),
resolution: 0.1ms
STI-PA (optional): Single value STI or CIS test result, modulation indices display,
individual band level results, error indicator, amplitude weighting acc. IEC 60268-16
release 2003
Electrical: Level RMS, THD+N, Polarity
Measurement microphone: Required for acquiring acoustical signals, NTI offers MiniSPL
or M2010 measurement microphones
|
The PMBL is a 2 channel passive line level merge box. Each channel has 2 balanced XLR/f inputs. The input signal is merged via a resistor network to a XLR/m output.The top side input is transformer isolated. Possible applications might be the routing of two mixing desks to one power amp or mixing a stereo signal down to mono. Our transformer technology allows for an unbalanced top side input to be sent out balanced.
Specifications:
- Each Channel: Input 1 transformer balanced XLR/f. Symmetrically decoupled through resistors
- Total ohmic value: 2 K Maximum level for THD
|
Reviews