The all metal DB DISPLAY MKII decibel display from American Audio is great for monitoring your sound volume. It also creates a great lightshow in your amp rack. Make sure your speakers stay in great shape by keeping those dBs under control through this monitoring system.
The LED display progresses from green through amber, to red. There are two different operating modes: Dot or Bar. A 5V power supply is included so you can get the unit plug in an running right away. The DB DISPLAY MKII is perfect a stage, church, club or bar install or for a mobile entertainer.
Specifications
• Designed to set in an amp rack to view your decibel level
• Creates a great light show in your amp rack
• Display progresses from green through amber to red
• Sensitivity adjustment on both left and right channels
• 2 separate modes: dot and bar
• Includes 5V power supply
• Line Inputs: Left & Right RCA / Left & Right XLR
• Line Outputs: Left & Right RCA / Left & Right XLR
• Voltage Operation: DC 5V, 500mA Power Supply included
• Dimensions: (LxWxH): 19” x 1.75” x 1.75” / 44.5mm x 483mm x 44.5mm
• Weight: 2.5 lbs. / 1.25kg. | Overview:
This is an infrared digital forehead thermometer with high precision, which is hand-held and portable for easy use. Non-contact design reduces cross infection effectively, widely used for measuring body temperature.
Features:
High precision infrared sensor, stable and reliable, for safe use, ensures accurate measuring, small error.
Alarm temperature can be set and once exceeded, it will give out a beep sound. Also, it supports the Mute mode.
Humanized design, LCD screen display with high brightness backlight can clearly show the body temperature.
Aim at the forehead (3-5cm), press the measuring button, and the LCD display will show the currently measured temperature.
Automatic store 32 sets of measurement data, you can view the data of the previous measurement.
Short press the Function Setting button to switch between Body and Object temperature modes.
Compact design, lightweight and portable, comfortable grip handle, easy to carry, convenient to use.
Suitable for baby, kids, and adult use and can be widely used in school, office, and at home, etc.
Note: The battery is not included.
Specification:
Model: ZK-YK1028
Measuring Method: Non-Contact
Measuring Distance: 3cm-5cm
Unit of Measurement: Celsius(℃), Fahrenheit(°F)
Measuring Range: 32℃-42.9℃ (89.6°F-109.2°F)
Max. Allowable Error: ±0.3℃ within range 35℃-42℃
Display Resolution: 0.1℃/0.1°F
Operating Environment: 16℃-35℃ (60.8°F-95°F), Humidity≤85%
Transportation Storage Environment: -20℃-50℃ (-4°F-131°F), Humidity ≤90%
Power: DC 3V (2 AAA Batteries Not Included)
Backlight: Highlight Backlight
Automatic Shut-down: 30s
Item Size: 15.0 * 8.5 * 4.3cm / 5.90 * 3.34 * 1.69in
Item Weight: 105g / 3.70oz
Package Size: 17.0 * 10.5 * 4.8cm / 6.69 * 4.13 * 1.89in
Package Weight: 156g / 5.50oz
Package List:
1 * Thermometer
1 * User Manual (English)
|
ARTSOUND A8862 LASERGRIP THERMOMETER
Temperature range: -32 C - 550 C Accuracy: 1,5% Power supply: 9V Weight: 258gr
| Tests XLR, 1/4 in., 1/8 in., TT, RCA and MIDI connectors.
The intelligent, CPU-controlled CT100 accepts virtually any connector type:
XLR, mono and TRS phone (1/4 in., 1/8 in., TT), RCA and MIDI. It shows
which input pin is connected to which output pin. Separate LEDs indicate
proper shield connection and phantom power presence. The CT100 also
offers an installed cable test mode and a continuity check plus a test tone
generator.
Features
3 modes: cable test mode, installed cable test mode, and test tone mode
Accepts XLR, mono and stereo TRS phone (1/4 in., 1/8 in., TT),
RCA and MIDI Connectors
Continuity check
Intermittent detect
Phantom power detect
Grounded shield detect
Test tone generation (1 kHz and 440 Hz)
Battery operation (requires 2 AA alkaline batteries) |
The MiniSPL is the perfect accessory to the Acoustilyzer & Minilyzer for
acoustical measurements.
The MiniSPL is a battery powered measurement microphone. Together
with the Acoustilyzer or Minilyzer, it forms an acoustical analyzer and integrating
sound level meter. Additionally it may be operated as a stand-alone microphone
e.g. connected to a balanced audio-line, a microphone-input or a sound-card.
Product-details
? Battery powered
? Factory-set sensitivity
? No phantom power required
? 1/2" microphone, class 2 acc. IEC 61672
? Omni-directional
? Supplied with mic clamp, wind protection
? Typical frequency response included
MiniSPL together with Acoustilyzer:
? SPL Meter / RTA
? Reverberation Time RT60
? Delay Time
? FFT Analyzer
? Speech Intelligibility STI-PA
MiniSPL together with Minilyzer:
? Measurements: SPL, min./max., Leq
? 1/3rd octave spectrum analyzer |
The tester allows to makea fast test connection for many type of audio and lighting cable, checking up to 7 connections (Neutrik? , Speakon?, XL3, XLR5, DIN RCA, Jack and BNC). Two rows of LEDs will light up to indicate which pin is connected correctly. a red lit LED and beep indicate short-circuited connection
Specifications: Battery: PP3 9V(not included) Accessory: Short Tester pinx2(included) Net Weight: 0.71Kg Dimensions: 178x121x44mm |