Content | RS232 Digital Sound Level Meter 8921/8922
- Deluxe super large LCD display w/ affordable price
- Meet IEC60651, type2 class standard
- Unique background noise absorber
- Features w/digital display and analog bar graph
- Professional and rigid design
- Auto / manual ranging ,6 measurement ranges in 10 steps
- Max hold
- Record max / min
- Fast / Slow response mode is selectable
- A /C weighting is selectable
- Easy to calibrate by standard calibrator
- AC/DC analog output
- Tripod mountable
- Backlight function to use in dark area (8922only)
SPECIFICATIONS
Measure range A weight: 30dB~130dB
C weight: 35dB~130dB
Digital display (6 ranges) 30~80, 40~90, 50~100, 60~110, 70-120, 80-130dB
Digital display resolution 0.1dB
Digital updating time 160mS
Quasi-analog bar (6 ranges) 30~80, 40~90, 50~100, 60~110, 70-120, 80-130dB
Quasi-analog bar resolution 1dB
Bar updating time 40mS
Accuracy at 94dB, 1KHz +/-1.5dB
Analog output Microphone AC 0.707Vrms(at full scale); DC 10mV/dB
Dia.6mm electric condenser microphone
Frequency range 31.5Hz~8KHz
Battery life time 30 hours typical
Windscreen LCD YES
size (mm) 42(H)x62(W)
Operating temp. 0~50oC
Operating RH% Humidity
Storage temp. -20~50oC
Storage RH% Humidity
Dimension(mm) Weight 254x77x37
Battery 9V battery x 1pc or 9VDC adaptor
Standard Package Meter/Battery/Manual/carry case
Optional Accessory Computer connection software kit
- DIGITAL DISPLAY WITH ANALOG GRAPH!
- BACKGROUND NOISE ABSORBER !
- BACKLIGHT FOR DARK AREA OPERATION!
- MAX / MIN RECORD, MAX HOLD !
- RS232 INTERFACE !
- MEETS IEC 651, TYPE 2 CLASS !
|
Digilyzer? DL1
Digital audio analyzer / audio meter with integrated speaker, audio lens and a
comprehensive event logger. Digital audio becomes simple by using the Digilyzer DL1.
The digital audio meter Digilyzer DL1 provides a comprehensive set of analysis
functions for digital, audio and video related audio signals.
It handles virtually all digital audio formats including ADAT and sampling frequencies
up to 96 kHz. The simple and intuitive operation allows the user to monitor, analyze
and troubleshoot any digital signals.
Debugging of digital audio signals becames easy with the assistance of the Digilyzer:
Features like the integrity check, the integrated speaker with audio lens function, the
logging functions, the ?over all? view of all important parameters and many more functions
to allow you to understand whats going on and finding faults easier than ever.
The Digilyzer is a handheld, battery powered device with optional mains power supply and
optional USB interface called MiniLINK.
MiniLINK, the USB interface for the Digilyzer allows documentation and data acquisition of
all DL1 functions in conjunction with the easy to use MiniLINK PC application. MiniLINK
supports online data logging up to several days. Read more about MiniLINK.
Product-details
? AES3, S/PDIF, TOS-Link
? ADAT Interface
? Sampling Frequency 32-96 kHz
? Digital Audio Analysis
? Carrier Status Analysis
? Carrier Signal Measurement
? Dual Domain Monitor Speaker
? Comprehensive Event Logger
| Non-Contact Laser Thermometer LCD Digital IR Infrared Thermometer GM400 Temperature Meter Gun Point -50~400 Degree
This infrared thermometer USES non-contact infrared sensing technology, the target of safety, preparation, fast, reliable measurement, is widely used in measuring the mechanical, chemical, ceramics, light industry, food, metallurgy, electric power, high temperature heat treatment and other industries, dangerous and difficult to close to the surface temperature measurement. Temperature measurement is widely used in the school laboratory and home.
Objects of any temperature greater than absolute zero radiation infrared energy, this energy to around at the speed of light transmission, infrared lens collects and gathers the infrared energy to the sensor, the sensor produces a low output voltage, the voltage is proportional to the temperature of the target object, voltage after processing for the temperature value.
- Not recommended for human use.
Main features:
1. Temperature range: -50 ℃ ~ 400 ℃ (-58 ℉ ~ 752 ℉)
2. Accuracy: ± 1.5 ° C (± 2.7 ° F) OR ± 1.5% ° C
3. ℃ / ℉ conversion selection function
4. Display resolution: 0.1 ℃ or 0.1 ℉
5. Working environment: 10 ℃ - ~ 40 ℃ (50 ℉ ~ 104 ℉), relative humidity: 10 ~ 90RH no condensation
6. Storage temperature: -10- ~ 40 ℃ (14 ℉ ~ 104 ℉)
7. Detection time: ≤ 0.8second
8. Distance coefficient ratio: 12: 1 (distance and measuring point size ratio)
9. Emissivity: Preset: 0.95
10. Power supply: 2 7 batteries (purchase, replace the battery more convenient)
11. Battery life of about 12 hours
12.LED backlight (easy to use at night)
13. Automatic shutdown function (about 10 seconds)
Model |
INFRARED THERMOMETER-GM400 |
Temperature range |
-50 ℃ ~ 400 ℃ (-58 ℉ ~ 752 ℉) |
Accuracy |
± 1.5 ° C (± 2.7 ° F) OR ± 1.5% ° C |
Display resolution: |
0.1 ℃ or 0.1 ℉ |
Working environment |
10 ℃ - ~ 40 ℃ (50 ℉ ~ 104 ℉), relative humidity: 10 ~ 90RH no condensation |
Storage temperature |
-10- ~ 40 ℃ (14 ℉ ~ 104 ℉) |
Detection time |
≤ 0.8second |
Distance coefficient ratio |
12: 1 (distance and measuring point size ratio) |
Emissivity Preset: |
0.95 |
Power supply |
2 7 batteries (purchase, replace the battery more convenient) |
Battery life |
12 hours |
LED |
LED backlight |
Automatic shutdown function |
about 10 seconds |
| With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power "pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics.
SPECIFICATIONS:
- Input: 2 x XLR/f balanced
- Nominal impedance: 200 Ω
- Output 1 x XLR/m balanced
- Load impedance >200 Ω
- Symmetrically decoupled through resistors
- Total ohmic value: 200 ohms
- Typical attenuation: 6 dB
- Housing: metal casing 110 x 73 x 42 mm
| GP-300 Infrared Thermometer is specially designed to take the body temperature of a person regardless of room temperature.
Features:
- Precise non-contact measurements
- User selectable ºC or ºF
- Selectable Body and Surface temp
- Set Alarm value for fever warning
- Access to multiple memory values up to 32 records
- Trigger lock
- Automatic Data Hold & Auto power off
- Automatic selection range and Display Resolution 0.1ºC (0.1ºF)
- Backlight LCD display
- Size 149 x 95 x 44 mm
- Weight 172g
- CE certified
Specifications
|
Model Number |
JZK-601 |
Memory groups |
32*2 groups |
Product Dimensions |
14.3* 9.3* 3.8 CM |
Business type |
Manufacturer |
Storage temperature |
-20-50°C |
Storage Humidity |
15%-90%RH |
Operating temperature |
5-40°C |
Operating Humidity |
40%-85%RH |
Display |
LCD crystal digital display |
Measuring method |
Infrared radiation temperature measurement |
Measurement range |
32~42.5℃ fro human body, 0-100℃ for objects |
Resolution |
0.1 degrees Celsius (0.1 degrees Fahrenheit) |
Accuracy |
0-39.9kpa(0-299 mmhg) |
Voltage |
3 V |
Power consumption |
|
|