Content |
| - SYSTEM POWER CONTROL It controls the power of the rack system over all working together with the PD-659. - AC OUTLET TERMINAL To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds. | | | | | PD- 658 | AC Outlet | Switched 2000W ⅹ3 | Operation Temperature | -10℃~+40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 10W | Weight(SET) | 4.6Kg/10.1 Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | | | |
|
toa-at-100upr Build-in Attenuator with Relay
Toa - 100V installation
Build-in Attenuator with Relay 100 W / 100 V
|
| - AUTOMATIC CHARGING Tapered charging circuitry charges your backup batteries without risk of overcharging. - EASY BATTERY MONITORING Integrated digital volt meter and digital ampere meter allow you to monitor the status of your batteries. | | | | | PB-607 | Battery Requirement | 24V DC | Starting Current | 3A Max. | Charge Complete Voltage | 27.3V ±10% | Operation Temperature | -10℃~+40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 130W | Weight(SET) | 7Kg/15.4Ib | Dimension(SET) | 482(W) x 88(H) x 280(D)mm/19(W) x 3.5(H) x 11(D)in | | | |
|
- CONSIDERATION OF USERʼS CONVENIENCE NUMERIC buttons and various function buttons are separated for timer program enter and convenience in use so that the user can easily operate. - ADOPTION OF VACUUM FLUORESCENT DISPLAY PANEL Adopting a vacuum fluorescent display of a dot matrix method enables to check operation status of each function at a glimpse. - PROGRAMMING USING A PC You can easily execute reservation setting thorough management program by connecting a PC to the RS-232C port. - VARIOUS MELODY AND SOUND OUTPUT You can generate various melodies and sounds by linking the flash memory mounted on this unit to our model, PV-632 (MULTI-VOICE FILE). - AC POWER OUTPUT CONTROL When PW-642 and other equipment are connected via the AC outlet terminal of PW-642, you can turn ON/OFF the AC outlet button in the front panel and manually control ON/OFF of the AC power connected to other device. - BACK-UP POWER You can continue to maintain the time counter for about a week though the inner back-up even though AC power turns off with current time set. There is no need of readjusting time even though AC power is applied. - MEASURE AGAINST POWER FAILURE A separate memory is used to prevent data extinguishment due to power failure or other unstable power. - AUTOMATIC RETURN In programming data using a key button on the front side of PW-642 without using a PC, no pressing any button is recognized as cancel of program entry to return to normal operation status. - AC POWER OUTPUT TIME ADJUSTMENT You can adjust the AC power output time of PW-642 by 1~20sec to prevent time delay from occurring in the interface with the outside power amp. - KEY LOCK You can protect reservations and userʼs setting. |
|
|
| | PW - 642 | Input Channel (Balanced) | 5CH | Output Channel (Balanced) | 4CH | Output Level | Maximum 1v | AC Power Output 1 | Maximum 500W | AC Power Output 2 | Maximum 30 w | Data Preservation Time | 7 days and more | Melody Time (15 settings total - 247 seconds) | No.1 | 2 seconds | No.2 | 3 Seconds | No.3 | 3 Seconds | No.4 | 5 Seconds | No.5 | 5 Seconds | No.6 | 7 Seconds | No.7 | 7 Seconds | No.8 | 10 Seconds | No.9 | 10 Seconds | No.10 | 15 Seconds | No.11 | 20 Seconds | No.12 | 30 Seconds | No.13 | 30 Seconds | No.14 | 40 Seconds | No15 | 60 Seconds | Operation Temperature | -10°C ~+ 40°C | Power Source | 100- 120 VAC or 220 -240VAC; 50/60 Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 10W | Weight(SET) | 5.7Kg/12.6Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | ※ Specifications and design subject to change without notice. | | | |
|
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source | 24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system) | Current Consumption | 120 mA (RM-300MF), 660 mA (with 3 RM-320F connected) | Frequency Response | 200 Hz - 15 kHz | Distortion | 1 % or less | S/N Ratio | 55 dB or more | Microphone | Unidirectional dynamic microphone with talk key, compressor (on/off switchable) | Volume Control | Microphone volume control, Buzzer volume control | Connection Cable | Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal | Maximum Cable Distance | Total 800 m (874.89 yd) | No. of Connectable RM-320F | Max. 3 units | Operation | Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch | Indicator | Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator | Operating Temperature | -5 ℃ to +45 ℃ (23 ゜F to 113 ゜F) | Operating Humidity | 5 % to 95 %RH (no condensation) | Finish | ABS resin, blueish gray (PANTONE 538 or its equivalent) | Dimensions | 200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“) | Weight | 1.1 kg (2.43 lb) (with wall mounting bracket unit) | Accessory | Wall mounting bracket unit …1, Wall mounting screw …2 |
|
The AT series high quality attenuators features 5 attenuation settings ,,OFF'' -18dB,-12db,-6dB,-0dB. An input range from 0.5W to 60W (model dependent), and push-in connectors. Push-in connector allows quick terminal cable connection. Stylishly finished, the AT Series will suit any décor. |
Reviews