INTER-M PD-658 SUB POWER DISTRIBUTOR

178.99 incl. GR VAT

Available on backorder

EAN: N/A
Installments calculation
CompareAdd to wishlist Submit Better Price
– SYSTEM POWER CONTROL It controls the power of the rack system over all working together with the PD-659. – AC OUTLET TERMINAL To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds. PD- 658 AC Outlet Switched […]

 

Read more

– SYSTEM POWER CONTROL

It controls the power of the rack system over all working together with the PD-659.

– AC OUTLET TERMINAL

To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds.

PD- 658

AC Outlet

Switched 2000W ⅹ3

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied AC mains transformer depends on country requirements)

Power Consumption

10W

Weight(SET)

4.6Kg/10.1 Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

Weight 4.90 kg

Reviews

There are no reviews yet.

Be the first to review “INTER-M PD-658 SUB POWER DISTRIBUTOR”

Your email address will not be published. Required fields are marked *

Quick Comparison

INTER-M PD-658 SUB POWER DISTRIBUTOR removeINTER-M RM-500 Remote Mic Station removeINTER-M RM-8000 Remote Mic Station removeJBL MTC 300T150 Transformer 70/100V removeINTER-M SC-624 2-CHANNEL SPEAKER LINE removeTOA RM-200M Remote Microphone Console remove
NameINTER-M PD-658 SUB POWER DISTRIBUTOR removeINTER-M RM-500 Remote Mic Station removeINTER-M RM-8000 Remote Mic Station removeJBL MTC 300T150 Transformer 70/100V removeINTER-M SC-624 2-CHANNEL SPEAKER LINE removeTOA RM-200M Remote Microphone Console remove
Image
SKUPD-658RM-500RM-8000MTC 300T150SC-624RM-200M
Rating
Price 178.99 incl. GR VAT 287.00 incl. GR VAT 424.00 incl. GR VAT 102.00 incl. GR VAT 392.00 incl. GR VAT 492.47 incl. GR VAT
Stock

Available on backorder

Available on backorder

Available on backorder

Available on backorder

Available on backorder

In stock

AvailabilityAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorderIn stock
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

- SYSTEM POWER CONTROL

It controls the power of the rack system over all working together with the PD-659.

- AC OUTLET TERMINAL

To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds.

PD- 658

AC Outlet

Switched 2000W ⅹ3

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied AC mains transformer depends on country requirements)

Power Consumption

10W

Weight(SET)

4.6Kg/10.1 Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

 

*Convenient Priority Broadcasting

*Convenient Installation and Construction without ID Setting

*RS-422 Communication between RM-500 and Z-500

*21 Zone Paging Selection

*Output Signal Level Display

*Multi Chime Options

*Weight: 1.6kg/3.5Ib

*DImensions(W×H×D): 200×206×70mm/7.9×8.1×2.8in

 

- CONVENIENT INSTALLATION AND CONSTRUCTION WITHOUT NEED OF ID SETTING.

- SELECTION OF VARIOUS CHIME BROADCASTINGS FOR MIC BROADCASTING (PRE/POST).

- CONVENIENT PRIORITY BROADCASTING.

- ADOPTION OF OUTPUT SIGNAL LEVEL DISPLAY.

- ADOPTION OF RS-422 COMMUNICATION METHOD TO SUPPORT A LONG DISTANCE.

Audio Output

0dB(Balanced)

Audio Input

Paging & RM MIC & LM MIC

-50dB(Balanced)

BGM(Main & Local)

-10dB(Balanced)

Tone Control

(100Hz & 10kHz)

Paging MIC

± 10dB

Audio Output

± 12dB

Frequency Response

BGM

± 3dB

MIC

± 3dB

S / N

BGM

Better than 75dB

MIC

Batter than 65dB

T.H.D.

BGM

Less than 0.05%

MIC

Less than 0.05%

Priority Control

Paging MIC > DRP > RM1> RM2 > RM3 > RM4 > LM-8000 > Main BGM

Phantom Power

DC 24V

Serial Interface

Communication Speed

9600bps

Communication Distance

Maximum 300m(UTP CAT%)

Operation Temperature

-10℃ ~ +40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied AC mains transformer depends on country requirements)

Weight(SET)

1.5kg / 3.2lb

Dimensions(SET)

200(W) x 70(H) x 206(D)mm

7.9(W) x 2.8(H) x 8.1(D)in

※ Specifications and design subject to change without notice.

The JBL MTC-300T150 150 Watt Transformer is intended for use with 70V or 100V distributed loudspeaker lines. It is ideally suited for the Control Series 300, especially the 300BB12 Backbox which includes a preinstalled mounting location.

- IT CAN CHECK SPEAKER WIRE OPEN, SHORT, AND EXCEED VALUE ACCORDING TO SETTING UP IMPEDANCE.

- IT AUTOMATICALLY CHECKS SPEAKER WIRES BY PROGRAM TIMER OPERATIONS. THE POSSIBLE SET UP TIMES ARE BETWEEN 20 MINUTES AND 200 MINUTES.

- RS-232C TERMINAL IN/OUT CONTROL WITH AMX/CRESTRON INTERFACE.

- DC 24V OPERATION.

- COMPACT DESIGN 2RU(3.5”).

- KEEPS STORED VALUES BY NON VOLATILE MEMORY

- ALERT SOUNDS WHEN FAULT IS FOUND

- BUZZER ON/OFF FUNCTION.

SC - 624

Power source

24VDC

Power Consumption

300mA

Weight

5.2Kg / 11.5lb

Dimensions (WxHxD)

1482 x 88 x380mm /19 x 3.5 x 15in

RM-200M - Five/ten zone console for VM-2120/2240 amplfiers

The RM-200M Remote Microphone that allows announcements to be made to any speaker zone and emergency announcements to all zones on a system with the VM-2120/2240 system management amplifiers.

These announcements can be made live or pre-recorded announcements
can be activated. The remote microphone is connected by cable to the
RM-210 Remote Microphone Extension unit.

SPECIFICATIONS:

 

Power Requirement 24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.)
Distortion Less than 1%
Frequency Response 100 - 10,000 Hz
Distortion Less than 1%
Signal-to-Noise Ratio More than 60 dB
Audio Output 0 dB*1, 600 O, balanced
Microphone Unidirectional electret condenser microphone, gooseneck type.
Speaker Zone Control Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast
Emergency Broadcast Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch
Voice Announcement Board Control Activation of 5 messages*2
Number of Connectable Units Up to 4
Communication System RS-485
Volume Control Microphone volume control
Connection Cable and Connector Category 5 STP cable, RJ45 connector
Communication Distance 800 m maximum in total
Finish ABS resin
Dimensions 190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded)

*1 0 dB = 1 V
*2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier.
Weight4.90 kg1.60 kg1.40 kg1.80 kg5.20 kg3.00 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 4.90 kg
Weight 1.60 kg
Weight 1.40 kg
Weight 1.80 kg
Weight 5.20 kg
Weight 3.00 kg