Content |
Stylus 78
Technical data |
| Frequency range | 20-15.000 Hz | Frequency response | 20-12.000 Hz + 2 / - 3 dB | Tracking ability at 315Hz at recommended tracking force *) | 60 µm | Compliance, dynamic, lateral | 15 µm/mN | Stylus type | spherical
| Stylus tip radius | 65µm | Equivalent stylus tip mass | 0,5 mg | Tracking force range | 1,75-2,25 g (17,5-22,5 mN) | Tracking force, recommended | 2,0 g (20 mN) | Tracking angle | 20° | Stylus colour | Black |
| | Recommended for following cartridges |
All Super OM, OM, OMP, TM, Concorde cartridges for playing 78 r.p.m. records
| *) Typical value |
Ortofon 530MKII Stylus Technical Data
Frequency range 20-25.000 Hz
Frequency response 20-20.000 Hz + 2 / - 3 dB
Tracking ability at 315Hz at recommended tracking force 80 µm
Compliance, dynamic, lateral 30 µm/mN
Stylus type Nude Fine Line
Stylus tip radius r/R 8/40 µm
Equivalent stylus tip mass 0,3 mg
Tracking force range 1,25-1,75 g (12,5-17,5 mN)
Tracking force, recommended 1,75 g (17,5 mN)
Tracking angle 20°
Stylus colour Black
Recommended for following cartridges Series 530 Mkll, 530, 530 P |
| Technical data
Frequency range 20-20.000 Hz
Frequency response 20-15.000 Hz + 2 / - 3 dB
Tracking ability at 315Hz at recommended tracking force *) 60 µm
Compliance, dynamic, lateral 15 µm/mN
Stylus type spherical
Stylus tip radius r/R 8/18 µm
Equivalent stylus tip mass 0,5 mg
Tracking force range 1,25-2,25 g (17,5-22,5 mN)
Tracking force, recommended 2,0 g (20 mN)
Tracking angle 20°
Stylus colour Black
Recommended for following cartridges - Dual TKS 49 S
*) Typical value | Genuine Original Stylus for OM 30, OM 30 Super, OMP30, LM 30, Concorde 30, TM 30H
Nude Fine Line
Interchangeability/Upgrade Group: A | Stylus 2M Blue
Technical data |
|
Frequency range |
20-25.000 Hz |
Frequency response |
20-20.000 Hz + 2 / - 1 dB |
Tracking ability at 315Hz at recommended tracking force *) |
80 µm |
Compliance, dynamic, lateral |
20 µm/mN |
Stylus type |
Nude Elliptical |
Stylus tip radius |
r/R 8/18 µm |
Equivalent stylus tip mass |
0,5 mg |
Tracking force range |
1,6-2,0 g (16-20 mN) |
Tracking force, recommended |
1,8 g (18 mN) |
Tracking angle |
20° |
Stylus colour |
Blue |
|
|
Recommended for following cartridges |
2M Blue |
*) Typical value | Stylus 3E
Technical data |
|
Frequency range |
20-20.000 Hz |
Frequency response |
20-18.000 Hz + 2 / - 3 dB |
Tracking ability at 315Hz at recommended tracking force *) |
60 µm |
Compliance, dynamic, lateral |
20 µm/mN |
Stylus type |
Elliptical |
Stylus tip radius |
r/R 8/18 µm |
Equivalent stylus tip mass |
0,5 mg |
Tracking force range |
1,5-2,0 g (15-20 mN) |
Tracking force, recommended |
1,75 g (17,5 mN) |
Tracking angle |
20° |
Stylus colour |
Black |
|
|
Recommended for following cartridges |
OM 3E, OMP 3E |
*) Typical value |
Reviews