Content |
MM01 - Measuring Mic
Precise electret-condenser test measurement microphone Uniform omni-directional pick-up pattern with superflat frequency response Accepts standard 9-52 V Phantom power Ideal for room analyzing and EQ correction Perfect for use with D-1500 RTA, or any other real time analyzer |
ACOUSTILYZER
The Acoustilyzer AL1 functionality complements and expands the ML1
Minilyzer with a new and comprehensive set of acoustical measurement
functions.
The optimized combination of electrical and acoustical features creates
the perfect all in one tool for sound/systems contractors, installers and
multi-media specialists. The Acoustilyzer AL1 is available as a palm-sized
portable acoustical analyzer or as firmware for Minilyzer owners with optional
available STI-PA measurement functionality.
Required Accessories:
The AL1 requires a measurement microphone for acquiring acoustical signals.
NTI offers the following microphones:
- MiniSPL, class 2 acc. IEC 61672
- M2010, class 1 frequency response (ext. phantom power supply required)
Product Details
Sound Pressure Level: Leq, short-time Leq , LE, Lmin, Lmax,
Real Time Analyzer: 1/1 or 1/3 octave band resolution SPL/LEQ display per
band, max - min display
Zoom FFT: Actual level and Leq, full band up to 0.7Hz resolution
Reverberation Time: RT60 with 1/1 octave band resolution, confidence indicator,
according to ISO3382
Delay Time: Propagation delay between electrical and acoustical signal (built in mic),
resolution: 0.1ms
STI-PA (optional): Single value STI or CIS test result, modulation indices display,
individual band level results, error indicator, amplitude weighting acc. IEC 60268-16
release 2003
Electrical: Level RMS, THD+N, Polarity
Measurement microphone: Required for acquiring acoustical signals, NTI offers MiniSPL
or M2010 measurement microphones
|
The PMBL is a 2 channel passive line level merge box. Each channel has 2 balanced XLR/f inputs. The input signal is merged via a resistor network to a XLR/m output.The top side input is transformer isolated. Possible applications might be the routing of two mixing desks to one power amp or mixing a stereo signal down to mono. Our transformer technology allows for an unbalanced top side input to be sent out balanced.
Specifications:
- Each Channel: Input 1 transformer balanced XLR/f. Symmetrically decoupled through resistors
- Total ohmic value: 2 K Maximum level for THD
| Non-Contact Laser Thermometer LCD Digital IR Infrared Thermometer GM400 Temperature Meter Gun Point -50~400 Degree
This infrared thermometer USES non-contact infrared sensing technology, the target of safety, preparation, fast, reliable measurement, is widely used in measuring the mechanical, chemical, ceramics, light industry, food, metallurgy, electric power, high temperature heat treatment and other industries, dangerous and difficult to close to the surface temperature measurement. Temperature measurement is widely used in the school laboratory and home.
Objects of any temperature greater than absolute zero radiation infrared energy, this energy to around at the speed of light transmission, infrared lens collects and gathers the infrared energy to the sensor, the sensor produces a low output voltage, the voltage is proportional to the temperature of the target object, voltage after processing for the temperature value.
- Not recommended for human use.
Main features:
1. Temperature range: -50 ℃ ~ 400 ℃ (-58 ℉ ~ 752 ℉)
2. Accuracy: ± 1.5 ° C (± 2.7 ° F) OR ± 1.5% ° C
3. ℃ / ℉ conversion selection function
4. Display resolution: 0.1 ℃ or 0.1 ℉
5. Working environment: 10 ℃ - ~ 40 ℃ (50 ℉ ~ 104 ℉), relative humidity: 10 ~ 90RH no condensation
6. Storage temperature: -10- ~ 40 ℃ (14 ℉ ~ 104 ℉)
7. Detection time: ≤ 0.8second
8. Distance coefficient ratio: 12: 1 (distance and measuring point size ratio)
9. Emissivity: Preset: 0.95
10. Power supply: 2 7 batteries (purchase, replace the battery more convenient)
11. Battery life of about 12 hours
12.LED backlight (easy to use at night)
13. Automatic shutdown function (about 10 seconds)
Model |
INFRARED THERMOMETER-GM400 |
Temperature range |
-50 ℃ ~ 400 ℃ (-58 ℉ ~ 752 ℉) |
Accuracy |
± 1.5 ° C (± 2.7 ° F) OR ± 1.5% ° C |
Display resolution: |
0.1 ℃ or 0.1 ℉ |
Working environment |
10 ℃ - ~ 40 ℃ (50 ℉ ~ 104 ℉), relative humidity: 10 ~ 90RH no condensation |
Storage temperature |
-10- ~ 40 ℃ (14 ℉ ~ 104 ℉) |
Detection time |
≤ 0.8second |
Distance coefficient ratio |
12: 1 (distance and measuring point size ratio) |
Emissivity Preset: |
0.95 |
Power supply |
2 7 batteries (purchase, replace the battery more convenient) |
Battery life |
12 hours |
LED |
LED backlight |
Automatic shutdown function |
about 10 seconds |
|
Palmer Pro MCT DMX 3-pin and 5-pin DMX and XLR cable tester
MCT DMX
This cable tester checks 3-pin and 5-pin DMX cables for continuity in fully automatic or manual pin selection modes. Pin connection status of the male and female cable ends is indicated by two rows of bright LEDs. In addition, the unitʼs 3-pin connectors can also be used to test XLR microphone cables. The DMX Cable Tester comes with two L-brackets for variable mounting options.
- Tests 3-pin and 5-pin DMX cables for continuity
- Also tests 3-pin XLR microphone cables
- Automatic test mode or manual pin 1 - 5 selection
- LED indicators
- Mounting brackets included
Product type
Test Equipment
Connectors
XLR (3-pin) , XLR (5-pin)
Controls
Auto Scan , On / Off , Scan switch
Indicators
LED chain
Operating voltage
2 x AA battery
Acoustic continuity test
no
Test cable
no
Cabinet material
sheet steel
Cabinet surface
powder coated
Width
240.2 mm
Height
48 mm
Depth
53 mm
Weight
0,7 kg
|
ARTSOUND A8862 LASERGRIP THERMOMETER
Temperature range: -32 C - 550 C Accuracy: 1,5% Power supply: 9V Weight: 258gr
|
Reviews