Content |
The evolution e 908 instrument microphone is available in four variants:
as e 908 D for drums and percussion
as e 908 B for wind instruments, congas, and drums with free-floating suspension system
as e 908 B ew for the wireless miking of saxophones using an evolution wireless instrument transmitter
as e 908 T ew for the wireless miking of trumpets using an evolution wireless instrument transmitter
Pick-up pattern : cardioid
Frequency response : 40 ... 20 000 Hz
Sensitivity in free field, no load : (1kHz) 4 mV/Pa, 0,56mV/Pa (e 908T-ew)
Equivalent noise level : e908B-ew = 30 dB(A); e908B & e908D = 35 dB(A), e908T-ew = 39 dB (A)
Max. Sound pressure level (aktiv) : 147 dB
Nominal impedance : 100 Ohm (e908B & e908D)
Min. terminating impedance : 2000 Ohm (e908B & e908D)
Phantom powering : 12 - 48 V / 3 mA (e908B & e908D)
Weight : ca. 140 g
Dimensions : Ø 47 x 193 mm
|
The CMX380 is a mini hanging cardioid microphone designed to be used in choirs, instrumental groups and theatres, but itʼs technical qualities and design will also justify itʼs use in several recording / reproduction applications.
The unidirectional cardioid polar pattern reduces feedback to an absolute minimum. Due to the flat frequency characteristic, users, musicians, singers and performers will experience a clear natural reproduction of their instrument or voice, even when exposed to loud powerful sounds.
The slimline modest design will not disctract the attention from the vocal of instrumental performance, and will flawlessly blend into the background.
- Model Name / Type: AUCMX380 / hanging back electret condenser microphone
- Polar Pattern: Cardioid
- Impedance: 200 ohms
- Frequency Response: 50 Hz - 18 kHz
- Sensitivity: - 42 +/- 3 dB
- Dynamic Range: 113 dB
- Phantom Power 11 - 52 V DC
- Diameter: 13,5 mm
- Length: 55 mm
|
- PA microphone with rugged, all-metal body
- Frequency response optimized for intelligibility
- Long useful life even in tough day-to-day usage
- Frequency response tailored to speech use
Rugged, affordable dynamic cardioid gooseneck microphone for general public address and communications use. The DGN 99 provides a frequency response tailored to speech use for optimum intelligibility as well as good offaxis rejection for high gain before feedback and suppression of unwanted ambient noise. The all-metal body ensures a long useful life for the microphone even in tough day-to-day use.
The DGN 99 E features a built-in XLR connector for quick connection, while the DGN 99 has been designed for permanent (single-hole or screw-on) installation and comes with a 6-ft. 4-in. (2-m) fixed, unterminated cable.
Ticket window, bank counter
Reception desk, restaurant
Houses of worship
|
2-inch (30 cm) Gooseneck Condenser Microphone, Cardioid, Attached XLR Preamp, Shock Mount, Flange Mount, Snap-Fit Foam Windscreen, Mute Switch, LED Indicator.
The Microflex Gooseneck microphones bring a whole new meaning to the word flexible. Beyond their fully adjustable goosenecks lies a new level of flexibility the new Microflex interchangeable condenser microphone cartridge. Designed for easy replacement and available in cardioid, supercardioid and omnidirectional polar patterns, the interchangeable cartridges offer wide frequency response and accurate sound reproduction for a broad variety of applications, such as houses of worship, courtrooms and conference centers. Plus, the condenser cartridges fit every model in the new Microflex product line for enhanced convenience and consistent sound.
Features
- Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum
- Interchangeable cartridges provide the right polar pattern for every application
- Balanced, transformerless output for increased immunity to noise over long cable runs
- Shock mount that provides over 20 dB isolation from surface vibration noise
- Locking flange mount for permanently securing microphone to lecterns, pulpits, or conference tables
- Snap-fit foam windscreen
Specifications
- Frequency Response: 50Hz to 17kHz
- Polar Pattern: Cardioid
- Output Impedance: rated at 150 ohms (180 ohms actual)
- Maximum SPL: 124.2 dB
- Signal to Noise Ratio: 66.0 dB
- Dynamic Range: 96.2 dB
- Power Requirements: 11 to 52 Vdc phantom, 2.0 mA
|
- Hypercardioid polar pattern
- 38 cm long
- 95° pickup angle
- For acoustically difficult environments
- Connects easily via XLR connector
The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.
Choosing polar patterns
Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.
The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance
Polar pattern |
Hypercardioid |
Frequency range |
50 to 19,000 Hz |
Sensitivity |
12 mV/PA = -38 dBV re 1 V/Pa |
Max. SPL |
125 dB (for 1% THD) |
Equivalent noise level |
|
Signal/noise ratio (A-weighted) |
>73 dB |
Impedance |
=2,000 ohms |
Supply voltage |
English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated) |
Powering |
|
Connector |
3-pin male XLR |
Finish |
matte black |
Dimensions |
CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.);
CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.) |
Net weight |
CGN 99 H/S: 480 g (17 oz.);
CGN 99 H/L: 500 g (17.7 oz.) |
|
Designed for Broadcast, House of Worship, Pro Music, and other applications. Half-cardioid polar pattern Boundary layer Ultra-thin profile (16 mm) housing Rubber non-slip bottom pad and strong steel screen Integrated pop filter Case Material Die cast zinc Connector Type 3-pin XLR Element Back Electret Condenser Finish Non-reflecting Black Finish White Impedance, Low-Z balanced 200 Ω Mic Type Boundary Open Circuit Voltage 25 mV/Pascal Polar Pattern Cardioid Wired/Wireless Wired Height 16 mm (0.63“) Width 94 mm (3.7“) Depth 123 mm (4.84“) Weight Net 12.63 oz (358 g) |
Reviews
There are no reviews yet.