Content | Sommer Mistral MCF08 8-Way Multicore Cable (Part number: 100-0101-08)
SOMMER MISTRAL DOUBLE SCREENED JACKETED STUDIO MULTICORE This multicore encompasses all the highly desirable features of a multicore cable. The cable is very flexible and treadable using a rubber like jacket material. The overall foil screen virtually stonewalls any unwanted magnetic and RF fields (excluded on 40 pair). It is secured to the outer jacket so is automatically removed when the jacket is stripped. Connection is via a twisted drain wire. The same applies to the foil screen surrounding individual pairs. Their jackets are pre-numbered and colour coded in groups of eight for rapid identification. Conductors and drain wires are tinned to protect against corrosion and oxidation. Both DC and self capacity losses are held to new lows by the use of generous sized conductors and an advanced dielectric material.All copper strands are of oxygen free copper. Surge impedance 85 ohms.
Advantages:
- Additional insulation for each wire pair with a numbered and colour-coded PVC sleeve
- Very flexible and tread-resistant owing to the use of a rubberlike jacket material
- Simple and fast handling due to the use of compound foil and a pre-twisted drain wire
- High bending cycles due to the tightly stranded Cu litz wires
- Returns on the cable splice are instantly recognisable by the colour coding on the conductor pairs
- High transmission quality even with excess distances (low capacitance!)
- Affordable price
Application:
- Ideal for studio installation and permanent installation
- Fixed installation in theatres, public buildings etc.
- Construction of dependable cable reel systems
Name |
SC-Mistral MCF08 |
Construction |
[08(2LI2Y0,22mm²)(ST)Y]F(ST)Y |
Jacket Ø [mm] |
14,80 |
Number of Channels (audio) |
8 |
Weight per 1 m [g] |
256 |
Fire load per m [kWh] |
1,21 |
Width [mm] |
14,8 |
Height [mm] |
14,8 |
EAN |
4049371000604 |
Name |
SC-Mistral MCF |
Properties |
Analog |
Properties |
Digital 110 Ω AES / EBU |
Properties |
OFC oxygen free copper |
Application area |
Mobile outdoor / indoor |
Application area |
Installation |
Application area |
Studio / Broadcast |
Application |
Multipair |
Colour |
black |
Colour detailed |
black, mat |
Signal transmission |
symmetrical |
Jacket material |
S-PVC |
Inner conductor (audio) |
2 |
Inner conductor (audio) [mm²] |
0,22 |
Inner conductor Ø (audio) [mm] |
0,53 |
AWG (audio) |
24 |
Shielding |
AL / PT foil + total foil shielding + filler strand |
Copper strands (audio) |
7 |
Copper strand Ø (audio) [mm] |
0,20 |
Conductor insulation material |
Foam / Skin-PE |
Conductor insulation Ø [mm] |
1,60 |
UV-resistant |
yes |
Style variant |
round |
Shielding factor [%] |
100 |
Packing |
bulk stock |
Temperature min. [°C] |
-30 |
Temperature max. [°C] |
70 |
Capac. cond./cond. per 1 m (audio) [pF] |
46 |
Capacity wire/wire at 1 ft. (audio) [pF] |
14,0208 |
Capac. cond./shield. per 1 m (audio) [pF] |
85 |
Capacity wire/electic screen at 1 ft. (audio) [pF] |
25,908 |
Impedance [Ω] |
110 |
Insulation resist. per 1 km [GΩ] |
1 |
Insulation resist. per 1000 feet [GΩ] |
0,3048 |
Insulation resist. per 1 km (audio) [GΩ] |
1 |
Insulation resist. per 1000 feet (audio) [GΩ] |
0,3048 |
Conductor resistance per 1 km [Ω] |
80 |
Conductor resistance per 1000 ft. [Ω] |
24,384 |
Shield. resistance per 1 km [Ω] |
75 |
Shield. resistance per 1000 ft. [Ω] |
22,86 |
| Product family features
- Dominant wavelength: 254 nm (OFR version)
Product family benefits
- Effective and environment-friendly disinfection without chemicals
- Low mercury content
- Long lifetime due to specific coating
- Ozone-free
Areas of application
- Efficient disinfecting of air, water and surfaces
Safety advice
PURITEC germicidal lamps emit high-intensity UV radiation that can cause sunburn and conjunctivitis. The skin and eyes must therefore not be exposed to direct or reflected unfiltered radiation.
PRODUCT DATASHEET
____________________________________________________________________________
Technical data
Product information
Order reference HNS-L 36W 2G11
Electrical data
Nominal voltage 106 V |
Lamp voltage 106 V |
Construction voltage 106.00 V |
Nominal current 0.44 A |
Lamp current 0.44 A |
Nominal wattage 36.00 W |
Photometrical data
Luminous intensity 7800 cd |
Radiated power 200…280 nm (UVC) 10.8 W |
Dimensions & weight
Diameter 40.0 mm |
Length 408.0 mm |
Lifespan
Lifespan 9000 h
Additional product data
Base (standard designation) 2G11
Capabilities
Dimmable No |
PHILIPS 72617940 TUV 15W SLV/25 UV-C Lamp G13 54V Sterilization lamp, MEDICAL Germicidal for universities, hospitals, jails and laboratories
TUV T8 lamps are double-ended UVC (germicidal) lamps used in professional water and air disinfection units. TUV T8 lamps offer almost constant UV output over their complete lifetime, for maximum security of disinfection and high system efficacy.
T8 G13 UV-C sterilization lamps TUV 15W G13 Philips 928039004005 8711500726179
Cap-Base G13 Bulb T26 Main Application Disinfection Useful Life 9000 hr
Lamp Wattage 15W Lamp Wattage Technical 15.9W Lamp Voltage 54V Lamp Current 0.34 A
Mercury (Hg) Content 2.0 mg
UV-C Radiation 4.9W
Base Face to Base Face A 437.4 (max) mm Insertion Length B 442.1 (min), 444.5 (max) mm Overall Length C 451.6 (max) mm Diameter D 28 (max) mm
TUV T8 - Guaranteed lifetime simplifying planned maintenance in professional applications
-Security of effective disinfection over the useful lifetime of the lamp -Maintenance can be planned in advance, virtually eliminating the need for expensive spot replacement of prematurely failed lamps -High system efficacy because it is not required to over-design the purification system to maintain effectiveness of disinfection -Good environmental choice because of lowest amount of mercury
Features -Short-wave UV radiation with a peak at 253.7 nm (UVC) for disinfection purposes -Protective inside coating ensures constant UV output over the complete lifetime of the lamp -Long lifetime of 18.000 hours (based on operation on a Philips electronic driver) -High reliability with the lowest percentage of lamps that fail prematurely in the market (90% of all lamps still operate on full output and quality after 15,000 hrs if operated on a Philips electronic driver) -Special lamp glass filters out the 185 nm ozone-forming radiation -High Output versions available for optimum UVC output per lamp length, allowing for reduction of system size -Warning sign on lamp indicates that the lamp radiates UVC
Applications -Air disinfection systems in professional applications such as universities, hospitals, jails and laboratories -Upper air and whole room disinfection equipment in hospitals, intensive care units and surgery rooms -Areas with low maintenance and/or disruptive costs -Fish ponds and process water units
| The all-digital fingertip pulse oximeter, based on all digital technology, is intended for the easy, fast and noninvasive spot-check measurement of functional oxygen saturation of arterial hemoglobin (SpO2) and heart rate.
Ability to operate for 30 hours continuously.
This option is especially useful in case our health is not at a very good level and we want constant monitoring.
The product is suitable for use in family, hospital, oxygen bar, social medical organization, physical care in sports and etc.
Suitable for:
- Patients with respiratory and heart problems, especially COPD, asthma, pneumonia
- Diagnosis of certain sleep disorders, such as apnea
- Pilots, flight attendants and generally people who travel a lot and are on airplanes under pressure over 10,000 feet continuously
- Climbers due to high altitude
- Athletes whose oxygen levels can be reduced with exercise
- Anyone who wants to monitor blood oxygen saturation
Features:
- Display Type: Three Color LED
- Measurement range: SpO2: 0% ~ 100% (Resolution: 1%).
- Accuracy: 70% ~ 100%: 2% 70%, unspecified.
- Pulse rate Measurement range PR: 30bpm ~ 250bpm (Resolution: 1bpm)
- Accuracy: 22bpm ή ± 2% (choose bigger)
- Resistance to ambient light: the difference between the value measured in conditions of artificial light or indoor natural light and that of the dark room is less than ± 1%.
- Power consumption: less than 25 mA
- Voltage: DC 2.6V ~ 3.6V
- Power: Alkaline batteries 1.5V (Size ΑΑΑ) x 2 (Not included)
- Autonomy: 20 hours
- Auto turnoff (Within 8\")
- Weight: 100 gr
- Dimensions: 5,8 x 3 x 3 cm
Package Contents:
1 x Pulse oximeter
1 x Strap
1 x User Manual
|
!!! Safety advice !!!
| ARTLIGHT STERPACK15 STERILIZATION PACKAGE INCLUDING PHILIPS 72617940 TUV 15W LAMP AND SINGLE TUBE MOUNT HOLDER BASE 45CM 1X15W
PHILIPS 72617940 TUV 15W SLV/25 UV-C Lamp G13 54V, MEDICAL Germicidal for universities, hospitals, jails and laboratories
TUV T8 lamps are double-ended UVC (germicidal) lamps used in professional water and air disinfection units. TUV T8 lamps offer almost constant UV output over their complete lifetime, for maximum security of disinfection and high system efficacy.
T8 G13 UV-C sterilization lamps TUV 15W G13 Philips 928039004005 8711500726179
Cap-Base G13
Bulb T26
Main Application Disinfection
Useful Life 9000 hr
Lamp Wattage 15W
Lamp Wattage Technical 15.9W
Lamp Voltage 54V
Lamp Current 0.34 A
Mercury (Hg) Content 2.0 mg
UV-C Radiation 4.9W
Base Face to Base Face A 437.4 (max) mm
Insertion Length B 442.1 (min), 444.5 (max) mm
Overall Length C 451.6 (max) mm
Diameter D 28 (max) mm
TUV T8 - Guaranteed lifetime simplifying planned maintenance in professional applications
-Security of effective disinfection over the useful lifetime of the lamp
-Maintenance can be planned in advance, virtually eliminating the need for expensive spot replacement of prematurely failed lamps
-High system efficacy because it is not required to over-design the purification system to maintain effectiveness of disinfection
-Good environmental choice because of lowest amount of mercury
Features
-Short-wave UV radiation with a peak at 253.7 nm (UVC) for disinfection purposes
-Protective inside coating ensures constant UV output over the complete lifetime of the lamp
-Long lifetime of 18.000 hours (based on operation on a Philips electronic driver)
-High reliability with the lowest percentage of lamps that fail prematurely in the market (90% of all lamps still operate on full output and quality after 15,000 hrs if operated on a Philips electronic driver)
-Special lamp glass filters out the 185 nm ozone-forming radiation
-High Output versions available for optimum UVC output per lamp length, allowing for reduction of system size
-Warning sign on lamp indicates that the lamp radiates UVC
Applications
-Air disinfection systems in professional applications such as universities, hospitals, jails and laboratories
-Upper air and whole room disinfection equipment in hospitals, intensive care units and surgery rooms
-Areas with low maintenance and/or disruptive costs
-Fish ponds and process water units
ARTLIGHT 01115 SINGLE TUBE MOUNT HOLDER BASE LED 45CM 1X15W
- IDEAL FOR FLUORESCENT LAMPS AND LED
- SINGLE LAMP
- LAMP LENGTH 45CM
- 1Χ15W
- STARTER IS NOT INCLUDED
- Contain Ballast 1x15w/ 230V / 0.31A / 50Hz / Cosφ 0.31 - Starter base (not the starter)
- Dimensions : 46cm (18") W x 5.5cm (2.2") D x 8.5cm (3.35") H
- Weight : 855 gr
|