Content |
The T-001T is a plug-in module designed for use with the 9000 Series amplifiers and can provide two independent balanced outputs. It can drive load of 600 Ω up to +16 dB. It can process effect for TONE/EQ/COMPRESSOR to two outputs independently..
* 0 dB = 1 V Power Source | +24 V DC, -24 V DC, +6 V DC | Current Consumption | 35 mA (at +24 V DC), 35 mA (at -24 V DC), 60 mA (at +6 V DC) | Output | 2 channels, max. +20 dB* (at 10 kΩ load), 600 Ω, electronically-balanced,
removable terminal block (3 pins) | Frequency Response | 20 - 20,000 Hz, +1, -3 dB | Total Harmonic Distortion + N | 0.005% (at 1 kHz, 20 - 20,000 Hz BPF, 5 V output, 10 kΩ load) | S/N Ratio | Over 73 dB (at 20 - 20,000 Hz BPF) | Residual Noise | Under -91 dB (at 20 - 20,000 Hz BPF, VOL: -70 dB) | Cross Talk | Over 87 dB (at 20 kHz) | D/A Converter | 24 bit DAC | Sampling Frequency | 48 kHz | Tone Control | Bass: ±12 dB (at 100 Hz)
Treble: %%p12 dB (at 10 kHz) | Parametric Equalizer | 10 bands, Frequency: 20 - 20,000 Hz, 31 steps, Variable range: ±12 dB,
Q: 0.3 - 5 | Speaker Equalizer | 15 (compatible with TOA speakers only) | High-pass Filter | -12 dB/oct, Variable frequency range: 20 - 400 Hz, 14 steps | Low-pass Filter | -12 dB/oct, Variable frequency range: 4,000 - 20,000 Hz, 8 steps | Compressor | Depth: 1 - 5 | Delay | 0 - 40 ms (1 ms step), maximum 40 ms (CH 1 + CH 2), mixer mode only | Operating Temperature | -10℃ to +40℃ | Finish | Panel: Aluminum, hair-line | Dimensions | 35 (W) × 78 (H) × 91.5 (D) mm | Weight | 82 g | Accessory | Removable terminal plug (3 pins) …2, Module mounting screw …2 |
|
*Convenient Priority Broadcasting
*Convenient Installation and Construction without ID Setting
*RS-422 Communication between RM-500 and Z-500
*21 Zone Paging Selection
*Output Signal Level Display
*Multi Chime Options
*Weight: 1.6kg/3.5Ib
*DImensions(W×H×D): 200×206×70mm/7.9×8.1×2.8in
|
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source
|
24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)
|
Current Consumption
|
120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)
|
Frequency Response
|
200 Hz - 15 kHz
|
Distortion
|
1 % or less
|
S/N Ratio
|
55 dB or more
|
Microphone
|
Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
|
Volume Control
|
Microphone volume control, Buzzer volume control
|
Connection Cable
|
Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
|
Maximum Cable Distance
|
Total 800 m (874.89 yd)
|
No. of Connectable RM-320F
|
Max. 3 units
|
Operation
|
Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch
|
Indicator
|
Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator
|
Operating Temperature
|
-5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
|
Operating Humidity
|
5 % to 95 %RH (no condensation)
|
Finish
|
ABS resin, blueish gray (PANTONE 538 or its equivalent)
|
Dimensions
|
200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)
|
Weight
|
1.1 kg (2.43 lb) (with wall mounting bracket unit)
|
Accessory
|
Wall mounting bracket unit…1, Wall mounting screw…2
|
|
RM-200M - Five/ten zone console for VM-2120/2240 amplfiers
The RM-200M Remote Microphone that allows announcements to be made to any speaker zone and emergency announcements to all zones on a system with the VM-2120/2240 system management amplifiers.
These announcements can be made live or pre-recorded announcements
can be activated. The remote microphone is connected by cable to the
RM-210 Remote Microphone Extension unit.
SPECIFICATIONS:
Power Requirement | 24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.) | Distortion | Less than 1% | Frequency Response | 100 - 10,000 Hz | Distortion | Less than 1% | Signal-to-Noise Ratio | More than 60 dB | Audio Output | 0 dB*1, 600 O, balanced | Microphone | Unidirectional electret condenser microphone, gooseneck type. | Speaker Zone Control | Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast | Emergency Broadcast | Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch | Voice Announcement Board Control | Activation of 5 messages*2 | Number of Connectable Units | Up to 4 | Communication System | RS-485 | Volume Control | Microphone volume control | Connection Cable and Connector Category | 5 STP cable, RJ45 connector | Communication Distance | 800 m maximum in total | Finish | ABS resin | Dimensions | 190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded) |
| *1 0 dB = 1 V
*2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier. |
|
| - FAN FOR PA RACK Auto fan operates when the inside temperature of PA RACK goes up. - MANUAL OPERATING When it's manual mode, the fan operates always regardless of temperature. - AUTO OPERATING When it's auto mode, the fan operates at 35°C. | | | | | PF- 602 | Operation Selector Switch | Manual, Auto, Operating temperature | Fan | 2 DC fans | Power Source | 24VDC | Power Consumption | 160mA | Weight | 4Kg/8.8Ib | Dimensions( W x H x D) | 482x 88 x 380 mm / 19 x 3.5 x 15in | ※ Specifications and design subject to change without notice. | | | |
|
Music Program Selector 1-6 with Relay
Toa - 100V installation |