Price | €1,300.00 €1,205.14 incl. GR VAT | €291.39 €252.02 incl. GR VAT | €559.16 €392.00 incl. GR VAT | €18.64 €16.78 incl. GR VAT | €49.67 €44.71 incl. GR VAT | €120.28 €102.00 incl. GR VAT |
Content |
The VX-2000DS Emergency Power Supply Unit supplies the DC power to each equipment in the VX-2000 system by connecting the VX-200PS Power Supply Unit. It keeps the battery unit that contains 2 × 12 V sealed lead batteries charged compensating for the temperature of the battery charging voltage. When the DC power supply from the VX-200PS stops, the VX-2000DS is automatically switched to the backup battery.
Power Source | 230 V AC | Power Consumption | 240 W max. | Applicable Battery | YUASA NP series (12 V × 2 or 4) | Charging Method | Trickle charging | Charging Current | 5 A max. | Charging Output Voltage | 27.3 V ±0.3 V (at 25℃)
Temperature correction coefficient: -40 mV/℃ | Power Supply Input | 6 M4 screw terminal | DC Power Output | 6 (25 A max. each) M4 screw terminal | Control Connector | RJ45 female connector for connecting the VX-2000SF Surveillance Frame.
Twisted-pair straight cable (TIA/EIA-568A standard)
Type of control signal: Battery check
charging circuit failure | Battery Connection | 1 pair of positive and negative terminals
Applicable cable diameter: AWG 6 - AWG 1/0 | Operating Temperature | 0℃ to +40℃ | Finish | Panel: Surface-treated steel plate | Dimensions | 482 (W) × 88.4 (H) × 377.6 (D) mm | Weight | 10.5 kg | Accessory | Rack mounting screw ……4
Fuse (T3.15 A L) ……1
Attention label (German) ……1 |
|
This model should be used with concerning equipment (emergency switcher-our model ES-9116, matrix-our model PX-9116, emergency panel-our model EP-9216). Specification Brand | InterM | Model | RG-9116 | Features | Speaker line switching; broadcasting status indicators (LED). | Power supply | 24V DC | Dimensions | 482 x 44 x 280 mm | Weight | 3,8 kg | Warranty | 12 months |
|
| - IT CAN CHECK SPEAKER WIRE OPEN, SHORT, AND EXCEED VALUE ACCORDING TO SETTING UP IMPEDANCE. - IT AUTOMATICALLY CHECKS SPEAKER WIRES BY PROGRAM TIMER OPERATIONS. THE POSSIBLE SET UP TIMES ARE BETWEEN 20 MINUTES AND 200 MINUTES. - RS-232C TERMINAL IN/OUT CONTROL WITH AMX/CRESTRON INTERFACE. - DC 24V OPERATION. - COMPACT DESIGN 2RU(3.5”). - KEEPS STORED VALUES BY NON VOLATILE MEMORY - ALERT SOUNDS WHEN FAULT IS FOUND - BUZZER ON/OFF FUNCTION. | | | | | SC - 624 | Power source | 24VDC | Power Consumption | 300mA | Weight | 5.2Kg / 11.5lb | Dimensions (WxHxD) | 1482 x 88 x380mm /19 x 3.5 x 15in | | | |
|
The ATT-30 from Inter-M Americas is a one-gang wall panel attenuator. The knob has four clearly-labeled steps to make easy adjustments. A screwless terminal block simplifies installation, and the sleek, modern design fits into any environment. The attenuator can handle up to 30W. |
Five attenuation settings (OFF, 0/-6/-12/ -16dB), over an input range from 0.5W to 30W. |
The JBL MTC-300T150 150 Watt Transformer is intended for use with 70V or 100V distributed loudspeaker lines. It is ideally suited for the Control Series 300, especially the 300BB12 Backbox which includes a preinstalled mounting location. |
Reviews
There are no reviews yet.