TOA VX-2000DS Emergency Power Supply

1,205.14 incl. GR VAT

Available on backorder

EAN: N/A
Installments calculation
CompareAdd to wishlist Submit Better Price
The VX-2000DS Emergency Power Supply Unit supplies the DC power to each equipment in the VX-2000 system by connecting the VX-200PS Power Supply Unit. It keeps the battery unit that contains 2 × 12 V sealed lead batteries charged compensating for the temperature of the battery charging voltage. When the DC power supply from the […]

 

Read more

The VX-2000DS Emergency Power Supply Unit supplies the DC power to each equipment in the VX-2000 system by connecting the VX-200PS Power Supply Unit. It keeps the battery unit that contains 2 × 12 V sealed lead batteries charged compensating for the temperature of the battery charging voltage. When the DC power supply from the VX-200PS stops, the VX-2000DS is automatically switched to the backup battery.

Specification
Power Source 230 V AC
Power Consumption 240 W max.
Applicable Battery YUASA NP series (12 V × 2 or 4)
Charging Method Trickle charging
Charging Current 5 A max.
Charging Output Voltage 27.3 V ±0.3 V (at 25℃)
Temperature correction coefficient: -40 mV/℃
Power Supply Input 6 M4 screw terminal
DC Power Output 6 (25 A max. each) M4 screw terminal
Control Connector RJ45 female connector for connecting the VX-2000SF Surveillance Frame.
Twisted-pair straight cable (TIA/EIA-568A standard)
Type of control signal: Battery check
charging circuit failure
Battery Connection 1 pair of positive and negative terminals
Applicable cable diameter: AWG 6 – AWG 1/0
Operating Temperature 0℃ to +40℃
Finish Panel: Surface-treated steel plate
Dimensions 482 (W) × 88.4 (H) × 377.6 (D) mm
Weight 10.5 kg
Accessory Rack mounting screw ……4
Fuse (T3.15 A L) ……1
Attention label (German) ……1

 

Weight 10.50 kg

Reviews

There are no reviews yet.

Be the first to review “TOA VX-2000DS Emergency Power Supply”

Your email address will not be published. Required fields are marked *

Quick Comparison

TOA VX-2000DS Emergency Power Supply removeINTER-M PD-658 SUB POWER DISTRIBUTOR removeINTER-M RM-500 Remote Mic Station removeINTER-M ATT-30 ATTENUATOR 330Ω, 7-30W removeTOA PGW-6R Music program selector removeTOA AT-100UPR Attenuator with Relay 100 W remove
NameTOA VX-2000DS Emergency Power Supply removeINTER-M PD-658 SUB POWER DISTRIBUTOR removeINTER-M RM-500 Remote Mic Station removeINTER-M ATT-30 ATTENUATOR 330Ω, 7-30W removeTOA PGW-6R Music program selector removeTOA AT-100UPR Attenuator with Relay 100 W remove
Image
SKUVX-2000DSPD-658RM-500ATT-30PGW-6RAT-100UPR
Rating
Price 1,205.14 incl. GR VAT 178.99 incl. GR VAT 287.00 incl. GR VAT 16.78 incl. GR VAT 78.14 incl. GR VAT 145.09 incl. GR VAT
Stock

Available on backorder

Available on backorder

Available on backorder

In stock

Available on backorder

Available on backorder

AvailabilityAvailable on backorderAvailable on backorderAvailable on backorderIn stockAvailable on backorderAvailable on backorder
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

The VX-2000DS Emergency Power Supply Unit supplies the DC power to each equipment in the VX-2000 system by connecting the VX-200PS Power Supply Unit. It keeps the battery unit that contains 2 × 12 V sealed lead batteries charged compensating for the temperature of the battery charging voltage. When the DC power supply from the VX-200PS stops, the VX-2000DS is automatically switched to the backup battery.

Specification
Power Source 230 V AC
Power Consumption 240 W max.
Applicable Battery YUASA NP series (12 V × 2 or 4)
Charging Method Trickle charging
Charging Current 5 A max.
Charging Output Voltage 27.3 V ±0.3 V (at 25℃)
Temperature correction coefficient: -40 mV/℃
Power Supply Input 6 M4 screw terminal
DC Power Output 6 (25 A max. each) M4 screw terminal
Control Connector RJ45 female connector for connecting the VX-2000SF Surveillance Frame.
Twisted-pair straight cable (TIA/EIA-568A standard)
Type of control signal: Battery check
charging circuit failure
Battery Connection 1 pair of positive and negative terminals
Applicable cable diameter: AWG 6 - AWG 1/0
Operating Temperature 0℃ to +40℃
Finish Panel: Surface-treated steel plate
Dimensions 482 (W) × 88.4 (H) × 377.6 (D) mm
Weight 10.5 kg
Accessory Rack mounting screw ……4
Fuse (T3.15 A L) ……1
Attention label (German) ……1

 

- SYSTEM POWER CONTROL

It controls the power of the rack system over all working together with the PD-659.

- AC OUTLET TERMINAL

To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds.

PD- 658

AC Outlet

Switched 2000W ⅹ3

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied AC mains transformer depends on country requirements)

Power Consumption

10W

Weight(SET)

4.6Kg/10.1 Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

 

*Convenient Priority Broadcasting

*Convenient Installation and Construction without ID Setting

*RS-422 Communication between RM-500 and Z-500

*21 Zone Paging Selection

*Output Signal Level Display

*Multi Chime Options

*Weight: 1.6kg/3.5Ib

*DImensions(W×H×D): 200×206×70mm/7.9×8.1×2.8in

 

The ATT-30 from Inter-M Americas is a one-gang wall panel attenuator. The knob has four clearly-labeled steps to make easy adjustments. A screwless terminal block simplifies installation, and the sleek, modern design fits into any environment. The attenuator can handle up to 30W.

Music Program Selector 1-6 with Relay
Toa - 100V installation

toa-at-100upr Build-in Attenuator with Relay
Toa - 100V installation


Build-in Attenuator with Relay 100 W / 100 V

Weight10.50 kg4.90 kg1.60 kg0.50 kg0.50 kg1.00 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 10.50 kg
Weight 4.90 kg
Weight 1.60 kg
Weight 0.50 kg
Weight 0.50 kg
Weight 1.00 kg