The VX-200SZ is an audio signal output module of the VX-2000 system with speaker line impedance detection. This module is to be mounted in the VX-2000SF Surveillance Frame and detects speaker line short circuits, open circuits by comparing impedance readings, and ground fault. Specification Power Source Supplied from VX-2000SF Current Consumption Under 150 mA Power […]

 

Read more

The VX-200SZ is an audio signal output module of the VX-2000 system with speaker line impedance detection. This module is to be mounted in the VX-2000SF Surveillance Frame and detects speaker line short circuits, open circuits by comparing impedance readings, and ground fault.

Specification
Power Source Supplied from VX-2000SF
Current Consumption Under 150 mA
Power Amplifier Link RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Twisted-pair straight cable (TIA/EIA-568A standard)
External Attenuator Control Output Plug-in screw connector, relay, no-voltage make contact output,
transfer type, withstand voltage: 30 V DC, 250 V AC,
contact current: Under 7 A (DC), under 7 A (AC)
Applicable cable diameter: AWG 24 – AWG 16
Speaker Output Plug-in screw connector
Applicable cable diameter: AWG 24 – AWG 16
Power Amplifier Input Plug-in screw connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Applicable cable diameter: AWG 24 – AWG 16
Fault Detection System Short circuit, open circuit (impedance detection method), ground fault
Finish Panel: Surface-treated steel plate
Dimensions 30.5 (W) × 132.6 (H) × 290.3 (D) mm
Weight 320 g
Accessory Plug-in screw terminal……1
Option Equaliser card: VX-200SE
Applicable Model VX-2000SF
Weight 0.32 kg

Reviews

There are no reviews yet.

Be the first to review “TOA VX-200SZ Impedance Detection Module”

Your email address will not be published. Required fields are marked *

Quick Comparison

TOA VX-200SZ Impedance Detection Module removeTOA AT-50UP 50w volume control removeINTER-M PD-659 POWER DISTRIBUTOR/CONTROL UNIT removeINTER-M RM-500 Remote Mic Station removeINTER-M PD-658 SUB POWER DISTRIBUTOR removeTOA RM-320MF Fireman's Microphone remove
NameTOA VX-200SZ Impedance Detection Module removeTOA AT-50UP 50w volume control removeINTER-M PD-659 POWER DISTRIBUTOR/CONTROL UNIT removeINTER-M RM-500 Remote Mic Station removeINTER-M PD-658 SUB POWER DISTRIBUTOR removeTOA RM-320MF Fireman's Microphone remove
Image
SKUVX-200SZAT-50UPPD-659RM-500PD-658RM-320MF
Rating
Price 226.00 incl. GR VAT 123.00 incl. GR VAT 314.00 incl. GR VAT 287.00 incl. GR VAT 178.99 incl. GR VAT 287.00 incl. GR VAT
Stock

Available on backorder

Available on backorder

Available on backorder

Available on backorder

Available on backorder

Available on backorder

AvailabilityAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorder
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

The VX-200SZ is an audio signal output module of the VX-2000 system with speaker line impedance detection. This module is to be mounted in the VX-2000SF Surveillance Frame and detects speaker line short circuits, open circuits by comparing impedance readings, and ground fault.

Specification
Power Source Supplied from VX-2000SF
Current Consumption Under 150 mA
Power Amplifier Link RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Twisted-pair straight cable (TIA/EIA-568A standard)
External Attenuator Control Output Plug-in screw connector, relay, no-voltage make contact output,
transfer type, withstand voltage: 30 V DC, 250 V AC,
contact current: Under 7 A (DC), under 7 A (AC)
Applicable cable diameter: AWG 24 - AWG 16
Speaker Output Plug-in screw connector
Applicable cable diameter: AWG 24 - AWG 16
Power Amplifier Input Plug-in screw connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Applicable cable diameter: AWG 24 - AWG 16
Fault Detection System Short circuit, open circuit (impedance detection method), ground fault
Finish Panel: Surface-treated steel plate
Dimensions 30.5 (W) × 132.6 (H) × 290.3 (D) mm
Weight 320 g
Accessory Plug-in screw terminal……1
Option Equaliser card: VX-200SE
Applicable Model VX-2000SF

The AT series high quality attenuators features 5 attenuation settings ,,OFF'' -18dB,-12db,-6dB,-0dB. An input range from 0.5W to 60W (model dependent), and push-in connectors. Push-in connector allows quick terminal cable connection. Stylishly finished, the AT Series will suit any décor.

- SYSTEM POWER CONTROL

You can control the power of your system by using this model.

- AC AND DC POWER SUPPLY

You can distribute AC and DC power through the AC outlet and DC terminals on the rear panel.

- USE OF EMERGENCY POWER SUPPLY

For emergency equipment power supply, an extra DC terminal is provided.

- REMOTE CONTROL

You can control the system power by remote control function even though the power switch on front is off.

- AC AND DC VOLT METER

This model uses digital volt meter displays of AC and DC.

- OPERATING MODE DISPLAY

You can easily check the operating mode by LEDs, AC or DC operating and emergency power.

PD-659

AC Outlet

Switched 2000W ⅹ3

Unswitched 700W ⅹ1

Remote Control

1

DC Power Output

DC 24V 5A

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied ACmains transformer depends on country requirements)

Power Consumption

190W

Weight(SET)

6.2Kg/13.6Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

※ Specifications and design subject to change without notice.

 

*Convenient Priority Broadcasting

*Convenient Installation and Construction without ID Setting

*RS-422 Communication between RM-500 and Z-500

*21 Zone Paging Selection

*Output Signal Level Display

*Multi Chime Options

*Weight: 1.6kg/3.5Ib

*DImensions(W×H×D): 200×206×70mm/7.9×8.1×2.8in

 

- SYSTEM POWER CONTROL

It controls the power of the rack system over all working together with the PD-659.

- AC OUTLET TERMINAL

To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds.

PD- 658

AC Outlet

Switched 2000W ⅹ3

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied AC mains transformer depends on country requirements)

Power Consumption

10W

Weight(SET)

4.6Kg/10.1 Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

 

The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.

 

 

Power Source

24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)

Current Consumption

120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)

Frequency Response

200 Hz - 15 kHz

Distortion

1 % or less

S/N Ratio

55 dB or more

Microphone

Unidirectional dynamic microphone with talk key, compressor (on/off switchable)

Volume Control

Microphone volume control, Buzzer volume control

Connection Cable

Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal

Maximum Cable Distance

Total 800 m (874.89 yd)

No. of Connectable RM-320F

Max. 3 units

Operation

Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch

Indicator

Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator

Operating Temperature

-5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)

Operating Humidity

5 % to 95 %RH (no condensation)

Finish

ABS resin, blueish gray (PANTONE 538 or its equivalent)

Dimensions

200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)

Weight

1.1 kg (2.43 lb) (with wall mounting bracket unit)

Accessory

Wall mounting bracket unit…1, Wall mounting screw…2

 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Weight0.32 kg0.40 kg6.20 kg1.60 kg4.90 kg1.10 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.32 kg
Weight 0.40 kg
Weight 6.20 kg
Weight 1.60 kg
Weight 4.90 kg
Weight 1.10 kg