With durable construction and unobtrusive appearance, the ES933C offers versatile solutions for speech, theater, orchestra and choir sound reinforcement and recording. The microphone's low-profile element provides a uniform cardioid polar pattern with 120º acceptance angle. Available in two colors: black (ES933C); white (ES933WC), the microphone offers unsurpassed immunity from radio frequency interference thanks to UniGuard® innovations. The ES933C also offers an 80 Hz low-cut UniSteep® filter that reduces pickup of low-frequency ambient noise.
- Designed for quality sound reinforcement, professional recording, television and other demanding sound pickup applications
- Small size and excellent response are ideal for suspension over choirs, instrumental groups and theater stages
- Low-profile element provides uniform cardioid polar pattern with 120º acceptance angle
- Available interchangeable elements permit angle of acceptance from 90º to 360º
- Superior off-axis rejection for maximum gain before feedback
- Requires 11V to 52V DC phantom power
- UniGuard® RFI-shielding technology offers outstanding rejection of radio frequency interference (RFI)
- Integral UniSteep® filter provides a steep low-frequency attenuation to improve sound pickup without affecting voice quality
- Available in two colors: black (ES933C) and white (ES933WC)
- RoHS compliant - free from all substances specified in the EU directive on hazardous substances
- Element: Fixed-charge back plate, permanently polarized condenser
- Polar Pattern: Cardioid
- Frequency Response: 30-20,000 Hz
- Low Frequency Roll Off: 80 Hz, 18 dB/octave
- Open Circuit Sensitivity: -40 dB (10.0 mV) re 1V at 1 Pa
- Impedance: 250 ohms
- Maximum Input Sound Level: 138 dB SPL, 1 kHz at 1% T.H.D.
- Dynamic Range: 109 dB, 1 kHz at Max SPL
- Signal to Noise Ratio: 65 dB, 1 kHz at 1 Pa
- Phantom Power Requiremens: 11-52V DC, 2 mA typical
- Switch: Flat, roll-off
- Cable: 15.2 m (50') long (permanently attached to microphone), 3.2 mm (0.13“) diameter, 2-conductor shielded cable, terminated with TA3F-type connector
- Accessories: ES933C: AT8109 two-stage foam windscreen; AT8452 steel hanger ES933WC: AT8109(WH) two-stage foam windscreen; AT8452(WH) steel hanger Both: AT8538 power module
|
- Mini condenser microphone with clip-on mount and flexible gooseneck
- Polar pattern: cardioid
- Frequency range: 60 Hz to 20 kHz
- Sensitivity: 5 mV/Pa (-46 dBV)
- Max. SPL: 130/132 dB SPL (for 1 %/3 % THD)
- Equivalent noise level: 31 dB(A)
- Power requirement: B 29 L battery power supply, MPA V L phantom adapter, AKG WMS bodypack transmitters
- Connector: 3-pin XLR
- Cable: 1.5 m (5 ft.)
- Finish: Matte black
- Adapter plate included for easy attachment to PT 400 and PT 40.
|
AKG GN 30 OC., 12 inch gooseneck for D.A.M.-microphone capsules, 3/8“-connector, programmable indicator LED, incl. 10ft. cable to open-end, black, for installations |
- Cardioid polar pattern
- 10 m (33 ft.) cable
- 125° pickup angle
- Especially suited for choir recordings
- Integrated spring steel clamp for optimum alignment
The new CHM 99 Condenser Hanging Microphone provides both ease of use and a high level of functionality. There is hardly any more affordable and simpler solution for recording choirs at worship centers. Suspended from the ceiling or a beam, the hanging microphone is aligned and then fixed in the correct position. Now use the spring steel clamp to adjust the correct angle, and off you go!
The CHM 99 is available in white or black.
XY stereo recording
Using two CHM 99 hanging microphones in an XY configuration (coincident pair) is a good way to make stereo recordings, particularly of choirs. However, sound source locations are defined only by intensity differences. Adjusting the angle between the microphones determines the width and depth of the stereo image.
ORTF stereo recording
Developed by the French Broadcasting Authority, this technique differs from the XY technique by recording not only intensity differences, but also delay differences. The capsules are aligned at an angle of precisely 110° and 170 mm / 6.7 in. apart.
Polar pattern Cardioid
Frequency range 70 to 18,000 Hz
Sensitivity 18 mV/PA = -35 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level 73 dB
Impedance =2,000 ohms
Supply voltage 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering |
- Hypercardioid polar pattern
- 38 cm long
- 95° pickup angle
- For acoustically difficult environments
- Connects easily via XLR connector
The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.
Choosing polar patterns
Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.
The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance
Polar pattern |
Hypercardioid |
Frequency range |
50 to 19,000 Hz |
Sensitivity |
12 mV/PA = -38 dBV re 1 V/Pa |
Max. SPL |
125 dB (for 1% THD) |
Equivalent noise level |
|
Signal/noise ratio (A-weighted) |
>73 dB |
Impedance |
=2,000 ohms |
Supply voltage |
English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated) |
Powering |
|
Connector |
3-pin male XLR |
Finish |
matte black |
Dimensions |
CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.);
CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.) |
Net weight |
CGN 99 H/S: 480 g (17 oz.);
CGN 99 H/L: 500 g (17.7 oz.) |
|
Polar pattern Cardioid
Frequency range 70 to 18,000 Hz
Max. SPL 125 dB (for 1% THD)
Equivalent noise level 73 dB
Impedance =2,000 ohms
Supply voltage 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering |