AKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone

No longer available!

129.00 incl. GR VAT

Out of stock

CompareAdd to wishlist Submit Better Price
Availability: No longer available! No longer available! SKU: CGN 99H/L Category:
Hypercardioid polar pattern 50 cm ( 20 in.) long 95° pickup angle For acoustically difficult environments Connects easily via XLR connector The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a […]

 

Read more

  • Hypercardioid polar pattern
  • 50 cm ( 20 in.) long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector

The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.

Choosing polar patterns

Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.

The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance

 

Polar pattern Hypercardioid
Frequency range 50 to 19,000 Hz
Sensitivity 12 mV/PA = -38 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level
Signal/noise ratio (A-weighted) >73 dB
Impedance =2,000 ohms
Supply voltage English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering
Connector 3-pin male XLR
Finish matte black
Dimensions CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.);
CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.)
Net weight

CGN 99 H/S: 480 g (17 oz.);
CGN 99 H/L: 500 g (17.7 oz.)

 

 Optional accessories

  B 18
Battery power supply
 
  H 500
Shock mount
 
  H 600
Shock mount
 
  PS 3 F-Lock
Installation hardware
 
  SA 60
Stand adapter
 
  ST 1
Mini-tripod
 
  ST 45
Table stand
 

 

Weight 0.48 kg

Reviews

There are no reviews yet.

Be the first to review “AKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone”

Your email address will not be published. Required fields are marked *

Quick Comparison

AKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone removeAKG C 519 M Miniature Clip-on Condenser Microphone removeAKG CGN 99H/S 38cm Hypercardioid Gooseneck Microphone removeAKG C 516 ML Cardioid instrument microphone with miniature mounting bracket removeSHURE WB-98H/C Instrument Microphone for Shure Wireless removeSHURE MX-412S-C 12 remove
NameAKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone removeAKG C 519 M Miniature Clip-on Condenser Microphone removeAKG CGN 99H/S 38cm Hypercardioid Gooseneck Microphone removeAKG C 516 ML Cardioid instrument microphone with miniature mounting bracket removeSHURE WB-98H/C Instrument Microphone for Shure Wireless removeSHURE MX-412S-C 12 remove
ImageAKG CGN 99HS 38cm Hypercardioid Gooseneck Microphone-artsound
SKUCGN 99H/LC 519 MCGN 99H/SC 516 MLWB98HCMX214SC
Rating
Price 129.00 incl. GR VAT 205.00 incl. GR VAT149.00 incl. GR VAT 150.00 incl. GR VAT 219.00 incl. GR VAT 268.00 incl. GR VAT
Stock

Out of stock

Available on backorder

Only 2 left in stock (can be backordered)

Available on backorder

Only 1 left in stock (can be backordered)

Available on backorder

AvailabilityOut of stockAvailable on backorderOnly 2 left in stock (can be backordered)Available on backorderOnly 1 left in stock (can be backordered)Available on backorder
Add to cart

Read more

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content
  • Hypercardioid polar pattern
  • 50 cm ( 20 in.) long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector

The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.

Choosing polar patterns

Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.

The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance

 

Polar pattern Hypercardioid
Frequency range 50 to 19,000 Hz
Sensitivity 12 mV/PA = -38 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level
Signal/noise ratio (A-weighted) >73 dB
Impedance =2,000 ohms
Supply voltage English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering
Connector 3-pin male XLR
Finish matte black
Dimensions CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.);
CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.)
Net weight

CGN 99 H/S: 480 g (17 oz.);
CGN 99 H/L: 500 g (17.7 oz.)

 

 Optional accessories

  B 18
Battery power supply
 

  H 500
Shock mount
 

  H 600
Shock mount
 

  PS 3 F-Lock
Installation hardware
 

  SA 60
Stand adapter
 

  ST 1
Mini-tripod
 

  ST 45
Table stand
 

 

  • Mini condenser microphone with clip-on mount and flexible gooseneck
  • Polar pattern: cardioid
  • Frequency range: 60 Hz to 20 kHz
  • Sensitivity: 5 mV/Pa (-46 dBV)
  • Max. SPL: 130/132 dB SPL (for 1 %/3 % THD)
  • Equivalent noise level: 31 dB(A)
  • Power requirement: B 29 L battery power supply, MPA V L phantom adapter, AKG WMS bodypack transmitters
  • Connector: 3-pin XLR
  • Cable: 1.5 m (5 ft.)
  • Finish: Matte black
  • Adapter plate included for easy attachment to PT 400 and PT 40.
  • Hypercardioid polar pattern
  • 38 cm  long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector
The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable. Choosing polar patterns Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid. The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance
Polar pattern Hypercardioid
Frequency range 50 to 19,000 Hz
Sensitivity 12 mV/PA = -38 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level
Signal/noise ratio (A-weighted) >73 dB
Impedance =2,000 ohms
Supply voltage English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering
Connector 3-pin male XLR
Finish matte black
Dimensions CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.); CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.)
Net weight CGN 99 H/S: 480 g (17 oz.); CGN 99 H/L: 500 g (17.7 oz.)
  • Cardioid instrument microphone with miniature mounting bracket
  • High mechanical-noise attenuation
  • Including wireless direct adapter for easy use with AKG pocket transmitters
  • Detachable microphone cable
  • Ideal for miking up accordions and guitar, piano, keyboard, or organ amplifiers
Polar patterncardiod
Frequency range60 Hz to 20 kHz
Sensitivity5 mV/Pa (-46 dBV)
Max. SPL130/132 dB SPL (bei k = 1 %/3 %)
Equivalent noise level31 dB(A)
Signal/noise ratio (A-weighted)63 dB
Impedance= 2000 ohms
Current consumption


The 98H/C is wireless version of Shure\'s Beta 98 clip-on instrument mic, and is designed to work with the Shure beltpack transmitters. With the ability to handle high SPL, the Beta 98H/C is ready for the demands of brass, woodwind, and percussion, and features a flexible integrated gooseneck with clip-on clamp for secure fit and precise positioning. No external mounting hardware required.

    

Tech Specs
  • Compatibility: All Shure w/TA4F (Tiny QG)
  • Microphone Type: Condenser
  • Polar Pattern: Cardioid
  • Frequency Response: 20Hz-20kHz
  • Max SPL: 143.5dB SPL
  • Signal to Noise Ratio: 63dB
  • Self Noise: 31dB (A weighted)
  • Connector: TA4F (For Shure)
  • Color: Black
  • Cable Length: 10 ft.
  • Weight: .1 lb.
  • Manufacturer Part Number: WB98H/C

 

2-inch (30 cm) Gooseneck Condenser Microphone, Cardioid, Attached XLR Preamp, Shock Mount, Flange Mount, Snap-Fit Foam Windscreen, Mute Switch, LED Indicator.

The Microflex Gooseneck microphones bring a whole new meaning to the word flexible. Beyond their fully adjustable goosenecks lies a new level of flexibility the new Microflex interchangeable condenser microphone cartridge. Designed for easy replacement and available in cardioid, supercardioid and omnidirectional polar patterns, the interchangeable cartridges offer wide frequency response and accurate sound reproduction for a broad variety of applications, such as houses of worship, courtrooms and conference centers. Plus, the condenser cartridges fit every model in the new Microflex product line for enhanced convenience and consistent sound.

Features

  • Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum
  • Interchangeable cartridges provide the right polar pattern for every application
  • Balanced, transformerless output for increased immunity to noise over long cable runs
  • Shock mount that provides over 20 dB isolation from surface vibration noise
  • Locking flange mount for permanently securing microphone to lecterns, pulpits, or conference tables
  • Snap-fit foam windscreen

Specifications

  • Frequency Response: 50Hz to 17kHz
  • Polar Pattern: Cardioid
  • Output Impedance: rated at 150 ohms (180 ohms actual)
  • Maximum SPL: 124.2 dB
  • Signal to Noise Ratio: 66.0 dB
  • Dynamic Range: 96.2 dB
  • Power Requirements: 11 to 52 Vdc phantom, 2.0 mA
Weight0.48 kg0.43 kg0.48 kg0.32 kg0.40 kg0.40 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.48 kg
Weight 0.43 kg
Weight 0.48 kg
Weight 0.32 kg
Weight 0.40 kg
Weight 0.40 kg

Recently Viewed Products